Войти:
Оценок - 5, средний балл: 4.4 ( )

Инструкция по эксплуатации Ingenico, модель I7910

Производитель: Ingenico
Размер: 149.78 kb
Название файла: e44caf44-a358-4cd6-a364-cceb08acac17.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• Plug the power adapter into the wall outlet and into the power connector at the back of i7910 terminal. Use the power adapter supplied with i7910. Many adapters can appear similar and will plug into i7910 but will not work properly causing erratic behavior, poor charging or damage to the unit. The i7910 with a fully charged battery can perform up to 200 transactions ( depending of the ticket size, transaction duration, time between transactions and backlight usage). The battery status is updated on the i7910 display ( the indicator depends of the application running on i7910): 1 bar represents 25 % of full capacity, 2 bars represent 50 % of full capacity, 3 bars represent 75 % of full capacity, 4 bars represent full capacity. - Do not short- circuit batteries. - Do not open or alter batteries’ outside structure. - Do not expose battery to fire, do not heat it. - Do not expose battery to liquid, do not freeze it. Store batteries at 40% charge level in a cool and dry area. The recommended storage temperature is 15°C (59°F) . Re-charge them to 40% every 3 to 4 months. 3.5. Connections: Turn the terminal off before connecting peripherals. 4. Power RS-2332 supply port connector • PERIPHERAL CONNECTION Connect the serial cable to the RS-232 port. Plug the other end of the serial cable to the device (PC, bar code or check reader etc. ). For detailed instructions, ask the equipment supplier. • POWER CONNECTION 5. Plug the power adapter radial jack into power supply connector at the back of i7910. Plug the power adapter into the wall outlet. The power supply: INPUT................................ 100-240 VAC, 60Hz OUTPUT............................................... 18VDC, 1A • OPTIONAL LinkBox and ComBox MODULES These modules provide additional connections: LinkBox provides a back-up dial connection (asynchronous and synchronous, V22bis or V34) and powered RS-232 port. ComBox provides two RS-232 ports, one of them powered (port marked RS232-2 provides power for the attached device). Connect LinkBox or ComBox to the i7910 RS-232 port, the letters “TOP” on a connector must be facing up. The green light (LinkBox only) indicates modem is ready. The light becomes red while dial connection is used. Connecting LinkBox to a telephone line: Plug the one end of a telephone cable into the port marked , and plug the other end of a telephone cable into a wall telephone jack. Attaching device to LinkBox or ComBox RS- 232 port: Connect the serial cable to the RS-232 port. Plug the other end of the serial cable to the device (PC, ECR, bar code or check reader etc. ). Normal Operation: Depending of the application installed in the terminal, i7910 displays icons indicating: • battery charge level, • charging status and • received signal strength. Depending of the application, the i7910 terminal powers down after a period of inactivity (in order to prolong battery life) . Pressing the green < OK> key powers i7910 back on. The i7910 with a fully charged battery can perform up to 200 transactions ( depending of the ticket size, transaction duration, time between transactions and backlight usage). Cleaning procedure: • The i7910 must be off for all cleaning operations. • Do not clean the i7910 with water but with a dry or only slightly damp cloth. • Do not use solvent, or abrasive products. If the terminal battery charging problem, contacts on the battery and on the terminal with a damp cloth Do not scratch or scrape the surface of the contacts. • If the print quality deteriorates, clean the print head to remove accumulated paper dust. The print head must be cleaned with the terminal powered off, using ethanol applied on a lint- free cloth. Be aware of the sharp paper cutter and hot printer parts. Ensure that the ethanol has completely evaporated before switching the terminal back on. 6. If you experience problems: HELP DESK NUMBER: 1- 888- 900- 8221 CUSTOMER SERVICE CENTERS: In Canada: In the USA: 6520 Gottardo Court 6195 Shiloh Road, Suite D Mississauga, Ontario, L5T 2A2 Alpharetta, Georgia 30005 1- 888- 900- 8221 ( 905- 795- 8221) 1- 800- 252- 1140 ( 678- 456- 1200) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: . Reorient or relocate the receiving antenna. . Increase the separation between the equipment ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории