|
Фрагмент инструкции
When using a label stock, move the Feed Gap Sensor so that it is in line with the centre of the label. When using a tag stock, move the Black Mark Sensor so that it is in line with the centre of a black mark. 3. Press the [PAUSE] key. 4. The printer enters the pause mode. 5. Press and hold the [PAUSE] key in the pause state until the following screen appears. 6. The sensor type is displayed. TRANSMISSIVE B-SX8T V1.0A 7. Select the sensor to be adjusted by using the [FEED] key. REFLECTIVE B-SX8T V1.0A TRANSMISSIVE B-SX8T V1.0A[FEED] Black mark sensor Feed gap sensor 8. Press and hold the [PAUSE] key until more than 1.5 labels (tags) NOTES: have been issued. 1. Failure to feed more than 1.5 The media will continue to be fed until the [PAUSE] key is released. labels may result in an incorrect (An automatic threshold setting for the selected sensor is completed threshold setting. by this operation.) 2. While the Top Cover is raised, the [PAUSE] key does not work PAUSE 3. A paper end error cannot be B-SX8T V1.0A detected during paper feed. 9. Press the [RESTART] key. ON LINE B-SX8T V1.0A 10. The printer returns to online mode. Send an issue command from the host computer to the printer. E2-78 2.PRINTER SETUP ENGLISH VERSION EO1-33057 2.12 Threshold Setting 2.12 Threshold Setting (Cont.) <5>SENSOR ADJ. [PAUSE] <5>SENSOR ADJ. [H]28°C [A]28°C [PAUSE] <5>SENSOR ADJ. [REFLECT] 3.5V [FEED] or [RESTART] <5>SENSOR ADJ. [REFLECT] 4.8V* [PAUSE] <5>SENSOR ADJ. [TRANS.] 2.4V [FEED] or [RESTART] <5>SENSOR ADJ. [TRANS.] 4.1V* [PAUSE] <5>SENSOR ADJ. [PE]R0.1V T4.8V [FEED] or [RESTART] <5>SENSOR ADJ. [PE]R0.1V T4.8V* [PAUSE] <5>SENSOR ADJ. [RIBBON] 3.1V [FEED] or [RESTART] <5>SENSOR ADJ. [RIBBON] 3.1V* [PAUSE] Manual threshold setting procedure If a paper jam error still occurs even after an automatic threshold setting has been performed, manually set the threshold voltage. To make a threshold value manually set in this section effective, select the Transmissive Sensor (when using manual threshold value) or Reflective Sensor (when using manual threshold value) within software commands or the printer driver. 1. While holding down the [FEED] and [PAUSE] keys, turn on the printer. 2. When “<1>DIAG.” appears on the LCD Message Display, release the [FEED] and [PAUSE] keys. <1>DIAG. Now, the printer is in the System Mode for system administrators. 3. Press the [FEED] or [RESTART] key until “<5>SENSOR ADJ.” appears on the LCD Message Display. <5>SENSOR ADJ. 4. Press the [PAUSE] key to enter the Sensor Adjustment Mode. <5>SENSOR ADJ. [H]28°C [A]28°C The Sensor Adjustment Mode contains sub menus for displaying the current status of each sensor and for storing “media level” voltage and “no media level” voltage. Each time the [PAUSE] key is pressed, the sub menus are displayed sequentially. (1) Sensor Status Display: Temperatures being detected by the Print Head Thermistor and the Ambient Thermistor are displayed. (2) Black Mark Sensor Status Display: Voltage being detected by the Black Mark Sensor is displayed. (3) Black Mark Sensor Adjustment: Using the media actually used, a “media level” voltage is stored. (4) Feed Gap Sensor Status Display: Voltage being detected by the Feed Gap Sensor is displayed. (5) Feed Gap Sensor Adjustment: Using the media actually used, a “media level” voltage is stored. (6) Black Mark Sensor/Feed Gap Sensor Status Display (No media): “No media level” voltage detected by the Black Mark Sensor/Feed Gap Sensor is displayed. (7) Black Mark Sensor/Feed Gap Sensor Adjustment (No media): “No media level” voltage is stored. (8) Ribbon End Sensor Status Display: Voltage being detected by the Ribbon End Sensor is displayed. (9) Ribbon End Sensor Adjustment: Using the ribbon actually used, a “ribbon level” voltage is stored. E2-79 2.PRINTER SETUP ENGLISH VERSION EO1-33057 2.12 Threshold Setting 2.12 Threshold Setting (Cont.) Voltage at a black mark Midpoint (Threshold voltage) Voltage at a print area <5>SENSOR ADJ. [REFLECT] 3.5V <5>SENSOR ADJ. [REFLECT] 4.8V* <5>SENSOR ADJ. [TRANS.] 2.4V Voltage at a label gap Midpoint (Threshold voltage) Voltage at a print area <5>SENSOR ADJ. [TRANS.] 2.4V <5>SENSOR ADJ. [TRANS.] 2.4V* <5>SENSOR ADJ. [PE]R0.1V T4.8V • When using the Black Mark Sensor (1) While “<5>SENSOR ADJ.” is displayed, press the [PAUSE] key until the message appears. The displayed value is a real-time voltage being detected by the Black Mark Sensor. <5>SENSOR ADJ. [PEFLECT] 3.5V (2) Measure a voltage at a blank part of media and a black mark, respectively. At this time, write down the midpoint between both voltages. (This value is used later for a threshold setting.) (Example) Print area = 4.8V, Black mark = 2.4V Midpoint = 3.6V NOTES: 1. When measuring a voltage of a blank area, be careful not to align a pre-print with the sensor by mistake. 2. Confirm that there is at least 0.7V difference between the two values. If the difference in voltage is less than 0.7V, a print start position cannot be detected. In that...
Эта инструкция также подходит к моделям:Торговое оборудование - EO1-33057 (1.65 mb)
Торговое оборудование - B-SX8T SERIES (1.65 mb)