Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Toshiba, модель TEC MA-1100-100 SERIES

Производитель: Toshiba
Размер: 2.73 mb
Название файла: 39575e1e-07d4-4ab0-9af1-36d7a8ce05ab.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Since every consideration has been given to safety, there is no danger of damaging the machine by incorrect operation. Please refer to this manual whenever you have any doubts concerning the machine. This machine has been manufactured under strict quality control and should give you full satisfaction. However, if the machine is damaged during transit, or there are any unclear points in this manual, please contact your local TEC representative. | The specifications described in this manual may be modified by TEC, if necessary. | Be sure to keep this manual for future reference. PRECAUTIONS 1. The keys on the keyboard work with a light touch. Avoid pressing the keys too hard. 2. Avoid handling the machine with wet hands. 3. Do not apply thinner or other volatile oils to the cabinet or other plastic parts. If dirty, wipe off with a piece of cloth soaked in neutral detergent and squeezed tightly. APPEARANCE AND NOMENCLATURE ---Display Receipt Cover Journal Window Receipt Outlet Validation Slip Inlet Ribbon Cover Cash Crawer | Power Switch ... The power switch is provided at the righthand side of the cabinet. The AC power is turned on when the switch is pushed to ON, and turned off when the switch is pushed to OFF. Clerk Locks GT Lock Control Lock Keyboard Power Switch Drawer Release Lock - 1 - CONTROL LOCKS AND MODE SELECTOR KEYS MODE LOCK X MGR BEG ' • □ LOCK —I (POSITION) LOCK .. REG MGR □ SET (FUNCTION) The register operations are locked when the Mode Lock is set to this position. Displays the current time in the front display as a standard feature. Normal cash register operations are carried out in this mode. However, the operations using the keys that have been programmed to require the "MGR" position cannot be done in this mode. The sale totals can be read and the programmed data can be verified in this position. This position allows to register all normal cash register operations to be carried out in the REG mode and the operations using the keys that have been programmed to require the MGR position. This is the "Negative Mode", which automatically processes all the entries in the reverse way, i.e., positive items into negative, and the negative into positive. All the resettable totals and their respective counters will be read and reset in this position. In this position, the register will allow programming operations. fjr\ SET Key The REG Key is used by the cashier who operates the register. This key can access the positions of LOCK and REG. The MGR Key is used by the store manager or a person authorized by the manager. This key can access the positions of LOCK, REG, X, and MGR. The MA Key is used by the store manager who will daily supervise the collection of money and the printout of trasactions recorded by the register. This key can access the positions of LOCK, REG, X, MGR, 0 , and Z. The SET Key is used by the programmer. This key can access the positions of LOCK and SET. - 2 - CLERK LOCKS Lock-and-Key Type (Standard) These locks are used to identify which clerk is operating the register. Clerk Keys (CL1, CL2, CL3, CL4) Each clerk should keep his/her clerk key. The register will not operate unless one of these keys is inserted and set to the corresponding position on the Clerk Locks. Each of the keys may be inserted and pulled out in the neutral position marked with the ,l." (point). for ten clerks) Push-key Type (Alternative Option, Ll 1 2 I 3 I 4 1 5 I 1 6 I 7 I 6 I 9 HO I This type may be installed in place of the Clerk Locks above, as an alternative option. In that case, ten clerk keys will be installed. Each clerk is assigned to his/her own. clerk key (1 through 10). The register will not operate unless one of these keys is pushed to stay down. GT LOCK This lock is provided to read or reset the accumulated sales totals not on the daily but on weekly or monthly basis. GTX Position: This position allows to read the accumulated totals. The GTX key as well as GTZ Key can access this position. GTZ Position: This position allows to read and reset the accumulated totals. The GTZ Key only can access this position. Gix NOTE: When the GT Lock is turned to either the GTX or GTZ position, the Mode Lock position or any Clerk Key ON/OFF condition will be disregarded. - 3 - DISPLAY The front display is located at the top of the register just above the keyboard. The display has two types of display — numeric display and message descriptors. I-»--- r RON 1 DISPLAY ->\ PLU DPT RPT AMO U N T D 1 E I B 3H 5 5 n 1 8 f SLP f f ALM REG f {-) ? ▼ SI TXBL r ST ▼ TL f CG r SHORT TRF l<- REAR or RE HO IE DISPLAY Numeric Display " AMOUNT (8 digits) DPT (2 digits) RPT (1 digit) Displays the numeric data, such as amount, quantity, etc. Displays the code which represents each Department Key. It stays lit when repeating the same department entry. Displays the repeat department entry count. The count is indicated from the second entry on, and ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории