Войти:
Оценок - 5, средний балл: 4 ( )

Инструкция по эксплуатации Datalogic Scanning, модель POWERSCAN D8330

Производитель: Datalogic Scanning
Размер: 1.75 mb
Название файла: powerscan_8300_um.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


EAN 8 IAAG1oI .. EAN 13 IAAH1rI .. UPC A IAAI1uI .. UPC E IAAJ1xI NO CHECK DIGIT TRANSMISSION EAN 8 IAAG0kI EAN 13 IAAH0nI UPC A IAAI0qI UPC E IAAJ0tI Enter Configuration Exit and Save Configuration I$+;I CODE SELECTION I$-?I CONVERSION OPTIONS UPC E to UPC A conversion IAAAAI UPC A to EAN 13 conversion IAACEI Enable only ISBN conversion IAP1nI Enable both ISBN and ISSN conversion IAP3tI UPC E to EAN 13 conversion IAABCI EAN 8 to EAN 13 conversion IAAD"I Enable only ISSN conversion IAP2qI Disable both ISBN and ISSN conversion IAP0kI Enter Configuration Exit and Save Configuration I$+;I CODE SELECTION I$-?I 2/5FAMILY disable the family IAC0QI • Read the desired family code • Interleaved 2/5 IAC1TI Normal 2/5 (5 Bars) IAC2WI Industrial 2/5 (IATA) IAC3ZI Matrix 2/5 (3 Bars) IAC4]I The pharmaceutical code below is part of the 2/5 family but has no check digit or code length selections. Code CIP/HR IAC5`I French pharmaceutical code • Read a check digit selection CHECK DIGIT TABLE no check digit control I12I .. check digit control and transmission I23I check digit control without transmission I34I • Read 4 numbers for the code length where: . First 2 digits = minimum code length. . Second 2 digits = maximum code length. The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only. Enter Configuration Exit and Save Configuration I$+;I CODE SELECTION I$-?I CODE39FAMILY disables the family IAB0OI .. Read the desired family code • Read a check digit selection CHECK DIGIT TABLE • Standard Code 39 .. no check digit control IAB1RI I12I check digit control Full ASCII Code 39 and transmission IAB2UI I23I check digit control without transmission I34I The pharmaceutical codes below are part of the Code 39 family but have no check digit selections. Code CIP39 IAB3XI French pharmaceutical code Code 32 IAB4[I Italian pharmaceutical code CODE LENGTH (optional) The code length selection is valid for the entire Code 39 family Read the code + 4 numbers for the code length where: set code length First 2 digits = minimum code length. Second 2 digits = maximum code length. IAB*=I The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only. Enter Configuration Exit and Save Configuration I$+;I CODE SELECTION I$-?I CODE128FAMILY disable the family IAI0]I • Read the desired family code • Code 128 IAI11=I control without transmission of check digit ISBT 128 IAI31CI enabling ISBT 128 automatically EAN 128 disables Puzzle Solver™. IAI21@I control without transmission of check digit Transmit GS Before Code Code EAN 128 uses the ASCII character to separate a variable length code field from the next code field. This character can also be transmitted before the code. .. disable IEQ0qI enable IEQ1tI If the character has been modified in the Character Replacement parameter, the new character is affected by this command. CODE LENGTH (optional) The code length selection is valid for the entire Code 128 family and is calculated on the output string. Read the code + 4 numbers for the code length where: set code length First 2 digits = minimum code length. IAILJI Second 2 digits = maximum code length. The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only. Enter Configuration Exit and Save Configuration I$+;I CODE SELECTION I$-?I CODE93 .. disable the code IAK0aI Code 93 IAK1dI control without transmission of check digit CODABARFAMILY .. disable the family IAD0SI • Read the desired equality control code • Read a start/stop transmission selection START/STOP CHARACTER TRANSMISSION Standard Codabar IAD113I no start/stop character equality control no transmission I12I Standard Codabar IAD127I start/stop character equality control transmission I23I Enter Configuration Exit and Save Configuration I$+;I CODE SELECTION I$-?I The Codabar ABC code below uses a fixed start/stop character transmission selection. Codabar ABC IAD212)I no start/stop character equality control but transmission. Codabar ABC Forced Concatenation enable Codabar ABC with forced concatenation IAD2321I non start/stop character equality control but transmission CODE LENGTH (optional) The code length selection is valid for the entire Codabar family Read the code + 4 numbers for the code length where: set code length First 2 digits = minimum code length. IAD*AI Second 2 digits = maximum code length. The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only. START/STOP CHARACTER CASE IN TRANSMISS...

Эта инструкция также подходит к моделям:
Торговое оборудование - POWERSCAN M8300 (1.75 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории