This completely automatic instrument quickly measures your blood pressure and pulse rate and displays them on an extra large digital panel. Your new HEM-712C/CLC uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood's movement through your brachial artery and converts the movements into a digital reading. The oscillometric method does not need a stethoscope so the monitor is simple to use. The monitor features an adjustable inflation control switch that allows you to set your correct inflation level before measurement. The cuff fills with air at the push of a button and automatically deflates when measurement is complete. Press the Memory button and. your last measurement appears for an easy comparison. Error indicators alert you to incorrect procedures and an automatic power-off function conserves on batteries. Please read this instruction manual thoroughly before using the Omron HEM-712C / CLC Automatic Inflation Blood Pressure Monitor. For specific information on your own blood pressure, CONTACT YOUR PHYSICIAN. 2 KNOW YOUR UNIT Systolic B ood Pressure DisDlav Button BATTERY INSTALLATION/REPLACEMENT 1. Slide the battery cover off in the direction of the arrow. 2. Install 4 "AA" size batteries so + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery cover. 4. If the Low Battery Indicator appears on the display, replace all four batteries. Long-life alkaline batteries are recommended. SYSTOLIC/mm Hg_DIASTOUC/mm Hg _zgt_ PULSE/m'm Low Battery Indication Note: Remove the batteries if the monitor will not be used for an extended period of time. 4 QUiM RlFERENCIE GUIDE 1. Avoid eating, smoking, and exercising for at least 30 minutes before taking a measurement. 2. Remove tight-fitting clothing from your upper arm. 3. Sit in a chair with your feet flat on the floor and place your arm on a table so that the cuff is at the same level as your heart. 4. Put your arm through the cuff loop making sure that the bottom edge of the cuff is approximately one-half inch above the elbow and that the Green Marker on the cuff is above brachial artery. 5. Pull the end of the cuff so that the entire cuff is evenly tightened around your arm and press the hook material firmly against the pile side of the Note: The cuff should fit snugly so that you can insert only one finger between the cuff and your arm 6. Set the Inflation Control Switch to your correct level and press the ON/OFF button. 7. After the Heart Symbol (O) appears on the digital panel, press the Start Button, and remain still until the measurement is complete. 8. When measurement is complete, the monitor displays your blood pressure and pulse rate, and automatically deflates the cuff. 9. Wait 2-3 minutes before taking another blood pressure measurement. You may require more rest time between readings depending on your individual physiological characteristics. cuff. 5 SUGGESTIONS BEFORE BLOOD PRESSURE MEASUREMENT 1. Know that eating, smoking, and exercising at least 30 minutes before taking a measurement raise your blood pressure. Stress also raises blood pressure. 2. Remove tight-fitting clothing from your left upper arm. 3. Measurement should be taken in a quiet place and you should be in a relaxed, seated position. Rest your arm on the arm of a chair or on a table so that the cuff is at the same level as your heart. 4. Remain still and do not talk during the measurement. 5. Keep a record of your blood pressure and pulse for your doctor. Remember, a single measurement does not provide an accurate indication of your true blood pressure. You need to take and record several measurements over a period of time. Blood pressure measurements fluctuate considerably. Information on daily activities such as eating, exercise, smoking, could be helpful to your doctor. 6 HOWTO APPLY THE ARM CUFF Sit in a chair with your feet flat on the floor and place your arm on a table so that the cuff is at the same level as your heart. If the cuff is assembled correctly, the hook material will be on the outside of the cuff loop and the metal D-ring will not touch your skin. Pile Side Material If not assembled pass the end of the cuff furthest from the tubing through the metal D-ring to form a loop. The smooth cloth should be on the inside of the cuff loop. Put your left arm through the cuff loop. The bottom of the cuff should be approximately 1/2 inch above the elbow. The Green Marker on the cuff should lie over the brachial artery on the inside of the arm. Tube should run down center of arm between the middle finger and ring finger Pull the cuff so that the top and bottom edges are tightened evenly around your arm. When the cuff is positioned correctly, press the hook material FIRMLY against the pile side of the cuff. Make certain the cuff fits snugly around your arm. The cuff should make good contact with your skin. Not...