Инструкция по эксплуатации HoMedics, модель BPA-100

Производитель: HoMedics
Размер: 1.8 mb
Название файла: c2738f03-8f4f-4d23-902f-bd5ec1f8020c.pdf
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


Press the User-Select button to select User 1 or User 2. 2. Continue to press the “M” button for approximately 5 seconds, then the data for the selected user will be erased automatically. Note: The data stored in memory for both users may be erased if any of the batteries are removed or if the power source is lost when using an AC adapter. (Users should first record the data in a Blood Pressure log before replacing or removing batteries or power source.) IMPORTANT NOTES REGARDING YOUR BLOOD PRESSURE MEASUREMENT • Take your reading in a comfortable measurements can be affected temperatures. Take your blood pressure at 23 normal body temperature. • Do not move or talk during measurement as this can elevate readings. • Do not move or cross legs during measurement. Keep feet flat on floor. • Do not touch cuff or monitor during measurement procedure. • It is suggested that you take your measurements at the same time each day and use the same arm for consistency. • Users should wait a minimum of 5 minutes before taking additional measurements. More time may be necessary depending upon your physiology. • The measurement results that users receive are for reference only. If users have any blood pressure concerns, please consult a physician. • Once inflation reaches 300 mmHg, the unit will deflate automatically for safety reasons. • This product is not suitable for people with arrhythmias. • This device may have difficulty determining proper blood pressure for users with poor circulation of blood, kidney for users who have suffered a 24 BPA-100IB_ENGSP.qxd 10/24/05 10:51 AM Page 25 CARE, MAINTENANCE & CLEANING 1. Clean the blood pressure monitor body and cuff carefully with a slightly damp, soft cloth. Do not press. Do not wash cuff or use chemical cleaner on it. Never use thinner, alcohol or petrol (gasoline) as cleaner. 2. Leaky batteries can damage the unit. Remove the batteries when the unit will not be used for a long time. 3. If the unit is stored near freezing, allow it to acclimate to room temperature before use. 4. This blood pressure monitor is not field serviceable. You should not use any tool to open the device nor should you attempt to adjust anything inside the device. If you have any problems with this device, please contact HoMedics Consumer Relations (contact information can be found on the warranty page). 5. Do not immerse the unit in water as this will in damage to the unit. 6. Do not subject the monitor and cuff to temperatures, humidity, moisture, and direct sunlight. Protect from dust. 25 7. Do not fold the cuff and tubing tightly. 8. Do not disassemble the monitor or cuff. If in need of repair, refer to the warranty section of this manual. 9. Do not subject the monitor to extreme shocks (do not drop on floor). 10. Do not inflate the cuff unless wrapped around arm. 11. Do not wrap the cuff around body parts other than your arm. 12. Do not drop or insert any object into any opening or hose. 13. This monitor may not meet its performance specifications if stored or used outside of these temperature and humidity ranges: • Storage Environment • Operating Environment Temperature: Temperature: 14°F~140°F (-10°C~60°C) 50°F~104°F (10°C ~40°C) Humidity: Humidity: 10~90% RH max. 40~85% RH max. 26 BPA-100IB_ENGSP.qxd 10/24/05 10:51 AM Page 27 POTENTIAL FOR RADIO/TELEVISION INTERFERENCE For USA only: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the product does cause harmful interference to radio or television reception, which can be determined by turning the product on and off, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the product and the receiver. • Connect the product into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. For Canada only: This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus out in the interference-causing equipment standard entitled Apparatus”, ICES-003 of the Canadian Department of Communications. Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Classe B prescrites dans la norme sur le materiel brouilleur: “ Appareils Numeriques”, ICES-003 edictee par le ministre des communications. 27 TROUBLESHOOTING If any abnormality arises during use, please check the fol...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории