Фрагмент инструкции
Backlighting, NEMA 4X Ranges and Resolution Resolution is fixed as indicated in table Ranges in Bold are standard. Contact Omega Engineering to order other ranges listed below. abs: Absolute reference (normally reads atmospheric pressure, reads zero at full vacuum) vac: Vacuum gauge, minus sign not used unless specified –30.0 inHg/15.0 psig 120.0 inHg 1600 mmHg 35.0 bar 1.000 kg/cm2 abs –30.0 inHg/100.0 psig 199.9 inHg abs 760 torr abs 70.0 bar 1.000 kg/cm2 vac –30.0 inHg/199.9 psig 199.9 inHg 1600 torr abs 140.0 bar ±1.000 kg/cm2 3.00 psig 50.0 oz/in2 2100 mmH2O 199.9 bar 1.000 kg/cm2 5.00 psig 80.0 oz/in2 3500 mmH2O 350 bar 1.999 kg/cm2 abs 15.00 psi abs 240 oz/in2 abs 199.9 cmH2O 19.99 kPa 1.999 kg/cm2 15.00 psig vac 240 oz/in2 vac 350 cmH2O 35.0 kPa 4.00 kg/cm2 ±15.00 psig ±240 oz/in2 1000 cmH2O 100.0 kPa abs 7.00 kg/cm2 abs 15.00 psig 240 oz/in2 2100 cmH2O 100.0 kPa vac 7.00 kg/cm2 30.0 psi abs 85.0 inH2O 199.9 mbar ±100.0 kPa 14.00 kg/cm2 30.0 psig 140.0 inH2O 350 mbar 100.0 kPa 19.99 kg/cm2 60.0 psig 400 inH2O abs 1000 mbar abs 199.9 kPa abs 35.0 kg/cm2 100.0 psi abs 400 inH2O vac 1000 mbar vac 199.9 kPa 70.0 kg/cm2 100.0 psig ±400 inH2O ±1000 mbar 400 kPa 140.0 kg/cm2 199.9 psig 400 inH2O 1000 mbar 700 kPa abs 199.9 kg/cm2 300 psig 850 inH2O 2000 mbar abs 700 kPa 350 kg/cm2 500 psig 7.00 ftH2O 2000 mbar 1500 kPa 1.000 atm abs 1000 psig 12.00 ftH2O 4000 mbar 1999 kPa ±1.000 atm 1999 psig 35.0 ftH2O 1.000 bar abs 3500 kPa 1.000 atm 3000 psig 70.0 ftH2O 1.000 bar vac 5000 kPa 4.00 atm 5000 psig 140.0 ftH2O ±1.000 bar 3.50 MPa 7.00 atm 6.00 inHg 230 ftH2O 1.000 bar 7.00 MPa 14.00 atm 10.00 inHg 480 ftH2O 1.999 bar abs 14.00 MPa 19.99 atm 30.0 inHg abs 150.0 mmHg 1.999 bar 19.99 MPa 35.0 atm 30.0 inHg vac 260 mmHg 4.00 bar 35.0 MPa 70.0 atm ±30.0 inHg 760 mmHg abs 7.00 bar abs 1000 g/cm2 abs 135.0 atm 30.0 inHg 760 mmHg vac 7.00 bar 1000 g/cm2 199.9 atm 60.0 inHg abs 760 mmHg 14.00 bar 2100 g/cm2 abs 340 atm 60.0 inHg 1600 mmHg abs 19.99 bar 2100 g/cm2 Accuracy (linearity, hysteresis, repeatability) ±0.25% of full scale ±1 least significant digit DPG1001B:±0.10% of full scale ±1 least significant digit Display (update rate, type, size) 3 readings per second nominal display update Ranges up to 1999:31/2 digit LCD, 1/2" digit height Ranges 2000 and up:4 digit LCD, 0.4" H digits, alphanumeric display of units BBL: Red LED display backlighting Controls & Functions Ranges up to 1999: Front pushbutton turns gauge on/off and starts shutoff timer. Turns on backlighting for 1 minute on BBL models. Ranges 2000 and up:Front pushbutton turns gauge on/off, starts shutoff timer. Pressing and holding front button zeros gauge. The zero feature is not used on absolute reference gauges. Calibration Ranges up to 1999:Front potentiometers, non- interactive zero & span, ±10% range Ranges 2000 and up:Internal pushbuttons, non- interactive zero, midpoint, & span, ±10% range. Calibration information stored in non-volatile memory. Shutoff Last character of model number on rear label indicates shutoff time. Contact Omega for other optional shutoff times. -5: 5 minute auto shutoff (standard) -NS: No auto shutoff, on/off via front pushbutton Connection Size 1/4" NPT male Sensor Material All wetted parts are 316 stainless steel Batteries 2 AA alkaline Battery Life 1000B, 1001B, 1100B ranges to 1999 Approx. 2500 hours 1000B, 1001B, 1100B ranges 2000 and up Approx. 2000 hours 1000BBL, 1100BBL ranges to 1999 Approx. 180 hrs (backlight on when gauge is on) 1000BBL, 1100BBL 2000 and up Approx. 150 to 1500 hrs depending on backlight usage Low Battery Indication Low battery symbol on display when batteries must be replaced Dimensions (see drawing on next page) DPG1000 3.5" W x 3.0" H x 2.0" D NEMA 4X housing Add approx. 0.75" to height for pressure fitting DPG1100 3.38" W x 2.88" H x 1.65" D housing Add approx. 0.75" to height for pressure fitting Weight (approximate) Gauge: 9 ounces Shipping weight: 1 pound Housing Material & Color DPG1000 Extruded aluminum case, light gray epoxy powder coated, black ABS/polycarbonate bezel, front and rear gaskets, polycarbonate label DPG1100 Light gray ABS/polycarbonate NEMA 4X case, rear gasket, polycarbonate label Overpressure 2 times sensor range 3000 psig range & metric equivalents: 5000 psig 5000 psig range & metric equivalents: 7500 psig Ranges 2000 and up: 112.5% out-of-range display: i – – – or i –.–.–.– depending on model Burst Pressure 4 times sensor pressure rating, or 10,000 psi, whichever is less Storage Temperature –40 to 203°F (–40 to 95°C) Operating Temperature –4 to 185°F (–20 to 85°C) Compensated Temperature 32 to 158°F (0 to 70°C) Temperature Stability ±0.5% span typical, ±1% span max. 0 to 82°C 2 DPG1000B, DPG1001B, DPG1000BBL, DPG1100B, DPG1100BBL CAUTION: Installation and Precautions Install or remove gau...
Эта инструкция также подходит к моделям:Тонометры - DPG1000BBL (191.18 kb)
Тонометры - DPG1001B (191.18 kb)
Тонометры - DPG1100B (191.18 kb)
Тонометры - DPG1100BBL (191.18 kb)