Войти:
Оценок - 3, средний балл: 5 ( )

Инструкция по эксплуатации A&D, модель TM-2655P

Производитель: A&D
Размер: 615.79 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


.. The humidity is less than 85% (non condensing). .. It is away from water, dust, chemicals, and corrosive or explosive gases. .. It is not exposed to direct sunlight. 2. Place the TM-2655/TM-2655P on a table solid enough to support its weight. 3. Adjust the height of the chair and table so that the arm insertion section is at the user’s heart level. Fig.4 Proper installation 4. Use the power cable provided with the device to connect between the AC INPUT connector and an electrical outlet. Using the anti-theft opening, secure the device to the table with a solid chain. Fig.5 Power cable connection Note Be sure to use the correct voltage for the power source. 9 4. OPERATION 1. Turn on the POWER switch located on the rear panel. When the POWER switch is turned on, all of the display symbols will appear for several seconds. Then; .. (TM-2655) “0” (zero) appears in the SYSTOLIC pressure display, indicating that the device is ready for measurement. .. (TM-2655P) The human sensor functions for three minutes. When it does not detect a person, “ . “ (dot) appears in the SYSTOLIC pressure display, indicating that the device is ready for measurement. Fig.6 POWER switch and SYSTOLIC display (TM-2566) 2. Take off your jacket. If you wear a thick jacket, take it off for a better measurement. Note Wearing a thick jacket may cause a faint pulse, and result in a measurement error. 3. Adjust the height of the chair and table. Adjust the height of the chair and table so that the arm insertion section is at your heart level. 4. Insert your arm into the arm insertion section. Note Be sure to insert your arm to the shoulder. 5. Press the START/STOP switch to start measurement. 6. The cuff will be pressurized automatically up to the predetermined pressure. Refer to “7-2 Description of the Functions” for details. 7. When pressurization is complete, the automatic exhaust mechanism will gradually reduce the pressure in the cuff. Just relax and remain still. Fig.7 Proper posture Fig.8 Measuring procedure 10 8. When the measurement is complete, the air is automatically released from the cuff and the cuff will become loose. 9. The measurement results appear in the display. 10. (TM-2655P) The measurement results are output to the printer. Fig.9 Measurement results Note .. To stop the measurement at any time, press the START/STOP switch. The quick exhaust will reduce the pressure in the cuff and the cuff will become loose. .. If the air is not exhausted even when the START/STOP switch is pressed, press the EMERGENCY STOP switch. .. If your arm can not be removed from the cuff due to the power failure, press the safety lever located on the front lower part of the device. It disconnects the clutch to loosen the cuff. .. Please wait for about 10 minutes before repeating the measurement. 11 5. SETTING THE CLOCK 5-1 Clock Adjustment Mode The clock is set in the clock adjustment mode. The clock adjustment mode display and switches used are as shown below: Fig.10 Switches for setting the clock and the clock adjustment mode display Table 3 Switches for setting the clock SELECT switch (1) Press to enter the clock adjustment mode. (2) (In the clock adjustment mode) Press to select the unit to be adjusted. The selected unit flashes. Each time the switch is pressed, the flashing unit changes: from “Year” to “Month”, “Date”, “Hours”, and “Minutes”. (3) Press to quit the clock adjustment mode. switch Press to change the flashing digit(s). 5-2 A Setting Example The following is the procedure to adjust the clock to 14:07, April 20, 2001. 1. Press the SELECT switch to make the SYSTOLIC display flash. 2. Press the switch to display “01” for 2001. 3. Press the SELECT switch to make the DIASTOLIC display flash. 4. Press the switch to display “4” for April. 5. Press the SELECT switch to make the PULSE display flash. 6. Press the switch to display “20”. 7. Press the SELECT switch to make the hours section of the TIME display flash. 12 8. Press the switch to display “14”. 9. Press the SELECT switch to make the minutes section of the TIME display flash. 10. Press the switch to display “07”. 11. Press the SELECT switch to return to the measurement mode. Note .. If no operation is performed for one minute, while setting the minutes section and for five seconds while setting the others, the settings performed so far will be confirmed and the device will return to the measurement mode. .. The clock can be set up to December 31, 2091. 13 6. INSTALLING THE PRINTER PAPER (This chapter is applicable only to the TM-2655P.) With the power turned on, install the printer paper as follows: 1. Cut the top end of the printer paper with scissors. If the end is not smooth, it may cause a paper jam or damage the printer head. 2. Press lightly on the center of the printer cover to open the cover. 3. Raise the lever located on the right side of the printer. Insert the printer paper into the paper feed slot as shown. The paper is fed automatically. 4. Press the PAPER FEED switch ...

Эта инструкция также подходит к моделям:
Тонометры - TM-2655 (615.79 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории