Войти:
Оценок - 5, средний балл: 3.8 ( )

Инструкция по эксплуатации A&D, модель UA-767

Производитель: A&D
Размер: 931.68 kb
Название файла: ua-767plus.pdf
Язык инструкции:itenesfr
Перейти к скачиванию



Фрагмент инструкции


Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. We recommend that you read through this manual carefully before using the device for the first time. Preliminary Remarks □ This device conforms to the European Directive 93/42 EEC for Medical Products. This is made evident by the CE mark of conformity accompanied by the reference number of the designated authority. □ The device is designed for use on adults only, not newborns or infants. □ Environment for use The device is for use indoors. Precautions □ Precision components are used in the construction of this device. Extremes in temperature, humidity, direct sunlight, shock or dust should be avoided. □ Clean the device with a soft, dry cloth. Never use thinner, alcohol, benzine, or wet cloth. □ Avoid tightly folding the cuff or storing the hose tightly twisted for long periods, as such treatment may shorten the life of the components. □ The device and cuff are not water resistant. Prevent rain, sweat and water from soiling the device and cuff. □ Measurements may be distorted if the device is used close to televisions, microwave ovens, cellular telephones, X-ray or other devices with strong electrical fields. □ Used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed of according to the applicable local regulations. English 2 Parts Identification DC Jack START button Air Connector Plug Air Socket Bb -t + + 1 X X 1.5 V Batteries (R6P or AA) Part of Display MEMORY Systolic Pressure Pressure Bar Indicator and WHO Classification Indicator Battery Indicator I.H.B. Indicator (Irregular heartbeat indicator) -Í 1J o i! 1J LI SS Diastolic Pressure 1 pç DIA I 03 mmHB Pulse Rate «io S6 A \ PUL. /min. Heart Mark English 3 Symbols Symbols Function / Meaning Recommended Action (!) Standby and Turn the device on. C+K r6(aa) |(-) Battery installation guide - Direct current SN Serial number 2Q02|wf] Date of manufacture n Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks. * The indicator while measurement is in progress. It blinks while detecting the pulse. Measurement is in progress. Remain as still as possible. Irregular Heartbeat indicator. (I.H.B.) The indicator that detects irregular heartbeats or any excessive body movement during the measurement. M Previous measurements stored in MEMORY. [|KH Full Battery The battery power indicator during measurement. cl ^ low Battery The battery is low when it blinks. Replace all batteries with new ones, when the indicator blinks. Frr Unstable blood pressure due to movement during the measurement. Try measurement again. Remain very still during the measurement. The systolic and diastolic values are within 10 mmHg of each other. Fasten the cuff correctly, and try the measurement again. The pressure value did not increase during inflation. Err CUF The cuff is not fastened correctly. Frr PUL. DISPLAY ERROR The pulse is not detected correctly. SYS Systolic blood pressure in mmHg DIA Diastolic blood pressure in mmHg. PUL./min Pulse per minute C €o366 EC directive medical device label |©N92 The certification trade mark registered to the Australian Communication English 4 Symbols Function / Meaning Recommended Action Authority by the Trademarks office. English 5 Using the Monitor 2. Remove the used batteries and insert new batteries into the battery compartment as shown, taking care that the polarities (+) and (-) are correct. Installing / Changing The Batteries 1. Slide the battery cover up to open it. Step 2 3. Slide the battery cover down to close it. 1+3' Use only R6P, AA batteries. I CAUTION □ Insert the batteries as shown in the battery compartment. If not, the device will not work. □ When a (LOW BATTERY mark) blinks in the display, replace all batteries with new ones. Do not mix old and new batteries. It may shorten the battery life, or cause the device to malfunction. □ cIZ3 (LOW BATTERY mark) does not appear when the batteries are drained. □ Battery life varies with the ambient temperature and may be shorter at low temperatures. □ Remove the batteries if the device is not to be used for a long time. The batteries may leak and cause a malfunction. □ Use the specified batteries only. The batteries provided with the device are for testing monitor performance and may have a limited life. Connecting The Air Hose Insert the air connector plug into the air socket firmly. Air Connector F Air Hose English 6 Using the Monitor Attaching The Arm Cuff 1. Wrap the cuff around the upper arm, about 2 - 3 cm above the elbow, as shown. Place the cuff directly against the skin, as clothing may cause a faint pulse, and result in a measurement error. 2. Constriction of the upper arm, caused by rolling up a shirtsleeve, may prevent accurate readings. How To Take Proper Measurements For the mo...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории