Войти:
Оценок - 4, средний балл: 3 ( )

Инструкция по эксплуатации MSC, модель Heart Rate Monitor

Производитель: MSC
Размер: 426.21 kb
Название файла: 3DxSetup_E_v1.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Nos. 4633216/4642606/5089775/5226340 and Pat. Pending U.S. Pat. Nos. 4633216/4642606/5089775/5226340 and Pat. Pending Read this quick-start manual first, and familiarize yourself with the basic operation of the unit. * The initial setup can be changed later. (See the user manual.) This manual describes the following procedures: 1 Parts Installation * If you already have CAT EYE Cyclocomputer Model CCCD100, you can use the same bracket and sensor; so you do not need parts installation. Just attach the 3Dx attachment on your bracket. 2 Attaching Chest Belt and Main Unit Copyright© 2000 CAT EYE Co.,Ltd. MSC3DxSE-000204 1 Printed in Japan 0687541 PUSH 3Dx attachment 3 Setting up Main Unit 4 Other Important Features For more detailed setup and operations, please read the user manual. E 2-8-25, Kuwazu, Hihashi Sumiyoshi-ku, Osaka 546-0041 Japan Service & Research Address for United States Consumers: CAT EYE Service & Research Center 1705 14 th St. 115 Boulder CO 80302 Phone: 303-443-4595 FAX: 303-473-0006 Toll Free: 800-5 CAT EYE URL: -1 -2- within 10cm Important The clearance between the sensors 23 and the magnets qw should be about 5mm. Align the center of the magnets qw and the sensor’s marking line while rotating the wheel or crank. Caution: Attach the sensor and the magnet within 10cm from the hub axle. Speed Sensor and Wheel Magnet A B Entire View marking line 1 Parts Installation Pay attention to the positions of the sensors and the magnets. Parts Names Make sure that the following parts are included in the package. 1 Bracket (Includes 3Dx attachment) 2 Speed Sensor (Short cord) 3 Cadence Sensor (Long cord) 4 Sensor Band A (L/S) 5 Sensor Band B 6 Nylon Ties 7 Sensor Rubber Pad 8 Bracket Rubber Pad 9 Bracket Rubber Pad with Holder 0 Screw q Wheel Magnet w Cadence Magnet Cadence Sensor and Cadence Magnet Speed Sensor and Wheel Magnet Cadence Sensor and Cadence Magnet 1 5 6 8 10 11 9 12 4 2 3 7 3Dx attachment -3- Magnet & Sensor ! Use a coin to attach the wheel magnet q temporarily to the right side spoke of front wheel. Caution: Attach the sensor and the magnet within 10cm from the hub axle. @ Attach the speed sensor 2 temporarily to the right front fork. Adjust the sensor 2 and the magnet q referring to the conditions A and B . After adjusting, tighten the screw 0 and the magnet q. $ Attach the cadence magnet w to the crank. Adjust the position of the sensor and the magnet referring to the conditions A and B . After adjusting, fix the cadence magnet w with the adhesive tape and the nylon tie 6. Bracket Attach the bracket rubber pad with holder 9 to the bracket 1 and mount it to the handle bar. Reference: If it does not fit well, use the rubber pad 8. Wire % Secure the wire along the frame using the nylon ties 6 and wind it round the brake cable up to the handlebar. Caution: Allow enough wire clearance in the area marked with . Crank Chain stay # Attach the cadence sensor 3 temporarily to the left chain stay. Reference: If the clearance between spoke and front fork is wider than 5mm, mount the sensor band 3and 4in an opposite way as shown. Spoke Front fork 2 Attaching Chest Belt and Main Unit 2 Attaching Chest Belt and Main Unit Chestbelt Heart Rate Sensor Before Wearing Chestbelt Heart Rate Sensor WARNING!! Pacemaker users should not use this unit. Caution: Attach the Chestbelt Heart Rate Sensor at the center of your chest. The electrode belts must be contacting your skin. When wearing the chest belt heart rate sensor, ensure that the top mark on the transmitter comes to the top. If worn upside down, signal’s transmittable distance might become shorter. For the best results, it is recommended to moisten the electrode areas, or smear electrolytic cream, which is used for electrocardiograph. If skin irritation occurs, the Chestbelt Heart Rate Sensor can be worn over lightweight underwear; in this case, always moisten the electrode areas. Chest hair may prevent correct measurement. How to wear Chestbelt Heart Rate Sensor 1.Adjust the length of the chestbelt to your chest size. Caution: Wear the chestbelt in comfortable way. If the chestbelt is too tight, you will feel pain during exercise. 2.Hook attachment belt to electrode belt at the front of your chest. Be sure to attach electrode area of the chestbelt to your skin closely. Reference: If you wear the chestbelt indirectly on the skin, moisten the electrode area for the best results. Dry skin will cause measurement error in winter, even if the chestbelt is attached to your skin directly. 3.Adjust the chestbelt so that the transmitter is placed at the front of your chest (under breast). Wear the chest belt heart rate sensor in the legible way (the top mark on the Top mark transmitter should come to the top). MainUnit 1Attachment Belt 2Electrode Belt 3Transmitter MSC Wireless Heart Rate Sensor TOP MSC Wireless Heart Rate Sensor Mount: 1.First hook the upper part of the unit. Then push the bottom part into the bracket while holding the lev...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории