Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Honeywell, модель Chronotherm IV T8611G

Производитель: Honeywell
Размер: 443.7 kb
Название файла: 265a0bf0-297a-44c6-b1d3-459b0db39f7c.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


IMPORTANT Only configurable numbers are shown on the device. Example: If thermostat does not have a system key, Installer Setup Number 12 will not be displayed. Review Table 3 factory-settings and mark any desired changes in the Actual Setting column. When Installer Setup is complete, review the settings to confirm that they match the system. Table 3. Thermostat Installer Setup Options. Select Not Used. Heating cycle rate. Not Used. System setting adjustment Installer Setup Number (PressTime . key tochange) 1 thru 4 5 6 (Not used) 7 8 thru 11 12 Factory Setting Display Description . . 6 Stage 2 . . 6 Emergency heat . . 1 Manual changeover Other Choices (Press ^ or Ў key to change) Actual Setting Display Description . . . 1, 6 or 9 1.1 cph 6.6 cph used for last stage of heat pump systems 9.9 cph used for electric heat . . 3, 6 or 9 . . . 0 or 2 0.Auto changeover 2.Fixed auto changeover 69-1406.1 4 T8611G CHRONOTHERMT8611G CHRONOTHERM IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS Table 3. Thermostat Installer Setup Options. (Continued) Adaptive Intelligent Recovery. control. Degree temperature display Not Used. Clock format. Not Used. Outdoor temperature display (models with OT terminals). Not Used. O/B terminal energized in heating or cooling. Deadband Not Used. Minimum off time for the compressor. Temperature range stops in heating. Temperature range stops in cooling. Not Used. Select 13 14 15 16 17 thru 23 24 25 thru 28 29 30 31 and 32 33 34 35 36 Installer Setup Number (PressTime . key tochange) 0 Adaptive Intelligent Recovery. control is activated (system starts early so setpoint is reached by start of program period). 1 Temperature is displayed in °C . . 0 12-hour clock format. . . 0 No outdoor temperature is displayed. . . 0 O/B terminal energized for reversing valve in cooling. 3 Heating and cooling setpoints can be set no closer than 3°F (1.5°C). . . 5 5 minute minimum off time for the compressor. 90 Highest heating setpoint setting. 45 Lowest cooling setpoint setting. . . Factory Setting Display Description 1 Conventional recovery (system starts recovery at programmed time). . Temperature is displayed in °C . . 1 24-hour clock format. . . 1 Outdoor temperature is displayed. Needs a C7089B1000 Outdoor Temperature Sensor to operate. . . 1 O/B terminal energized for reversing valve in heating 4 thru 10 Heating and cooling setpoints can be set no closer than the chosen value: 4.4°F (2°C) 5.5°F (2.5°C) 6.6°F (3°C) 7.7°F (3.5°C) 8.8°F (4°C) 9.9°F (4.5°C) 10.10°F (5°C) . . 0 thru 4 Minimum number of minutes (0 thru 5) the compressor will be off between calls for the compressor. 40 thru 89 Temperature range (1°F increments) of heating setpoint settings. 46 thru 99 Temperature range (1°F increments) of cooling setpoint settings . . Other Choices (Press ^ or Ў key to change) Display Description . . . . . . Actual Setting 5 69-1406.1 T8611G CHRONOTHERMT8611G CHRONOTHERM IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS Table 3. Thermostat Installer Setup Options. (Continued) Select Installer Setup Number (PressTime . key tochange) Factory Setting Other Choices (Press ^ or Ў key to change) Actual Setting Display Description Display Description Temperature display adjustment. 37 0 No difference in displayed temperature and actual room temperature. -3 thru 3 1.Display adjusts to 1°F higher than actual room temperature. 2.Display adjusts to 2°F higher than actual room temperature. 3.Display adjusts to 3°F higher than actual room temperature. -1.Display adjusts to 1°F lower than actual room temperature. -2.Display adjusts to 2°F lower than actual room temperature. -3.Display adjusts to 3°F lower than actual room temperature. Furnace Air Filter Timer. 43 0 Off 1, 2, 3, 4 1 . 10 days 2 . 30 days 3 . 60 days 4 . 120 days (Times counted when heat, cool or fan is running.) Humidifier Pad Monitor. 44 0 Off 1, 2, 3 1 . 90 days 2 . 180 days 3 . 365 days (Times counted by calendar days in heat mode.) Ultraviolet (UV) Air Treatment System Lamp Monitor. 45 0 Off 1 1 . 365 days (Times counted by calendar days in any mode.) IMPORTANT Review the settings to confirm that they match the system. Press Run Program to exit the Installer Setup. The thermostat has saved the Installer Setup changes and initiated a reset in order to operate using the new settings. Be sure to set the current day and time immediately. 69-1406.1 6 T8611G CHRONOTHERMT8611G CHRONOTHERM IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS Setting Current Day and Time INSTALLER SYSTEM-TEST 1. Press Set Current Day/Time. Use the Installer System Test to check the thermostat NOTE: On initial powerup or after an extended power operation. Refer to Table 4 for a list of the available loss, 1:00 pm flashes on the display until a key system-tests. is pressed. M14619ProgramSystemFanProgramTempSetCurrentDay/TimeSetCurrentDay/TimeWakeLeaveReturnSleepDayHeat/CoolSettingsDaylightTimeCopySetDay/TimeMonPM 2. Press Day until the current day is displayed. NOTE: Sun=Sunday, Mon=Monday, Tue=T...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории