Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Honeywell, модель 43157

Производитель: Honeywell
Размер: 228.87 kb
Название файла: 43157.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


NOTE: Unless the reset button is pressed, the thermostat will not change temperature mode. Fan Option Temperature (SW3) Display (SW4) C F HG – HE NORM – HP Cooling SPAN Setting Mode Your thermostat is set at the factory to cycle at 1°F (0.5°C) above and below the set temperature. (Span = 2) This setting has been designed to provide a comfortable room temperature under most all conditions. However, if you find your system cycling too fast or too slow, then the Span can be adjusted to modify the cycle time. Day Program 1 Program 2 Program 3 Program 4 Monday – Friday Time Temp Time Temp Time Temp Time Temp Saturday – Sunday Time Temp Time Temp Time Temp Revising Programs PROGRAM PROGRAM To temporarily change the current set temperature without af Temporary Manual Override ON position. To run the Fan on continuously, slide the Fan switch to the and heat pump operation, the Fan will turn on with the system. be turned on by your furnace after its warm-up delay. For electric heat, air conditioning, on along with normal operation of your system. In a normal gas or oil fur The Fan switch should normally be located in the AUTO position. The Fan will be tur Fan Switch to prevent the possibility of a rapid system On-Off. the wallplate, slide the System Selector to the OFF position NOTE: Anytime you install or remove the thermostat from the operating mode of the thermostat. You may select COOL, OFF The System Selector switch on the front of the thermostat determines System Selector Switch programs. You can also make changes at any time. To review your program settings, press Reviewing Programs STEP 6: or or HOLD/RET HOLD/RET Figure 7 OPERATION Setting Day and Time STEP 1: DAY/TIME STEP 2: DAY/TIME STEP 3: DAY/TIME ¦ The LCD will show this information when batteries are first installed, or after the Reset button is pressed. The temperature will update after a few seconds. ¦ During time and day setting mode, the temperature and program displays will go blank. ¦ Example: Set the Thermostat to the current time of 2:16 pm on Saturday. Refer to the Steps below. ¦ Press to enter time and day setting mode. The current hour and the AM / PM indicator will be flashing. ¦ Press to change the Hour up or down to the current hour. Note the AM / PM indicator, as the display will change at 12 AM and 12 PM. ¦ Press again to change from hour setting to minute setting. The current minute will be flashing. ¦ Press to change the Minute up or down to the current minute. M PM ¦ Press again to change from minute setting to day setting. The current day will be flashing. ¦ Press to change the Day up or down to the current day. M PM M AM 4 TEMP System Selector (SW6) STEP 4: n Press again to change back to the SA DAY/TIME normal display. or PM HOLD/RET 2 TEMP NOTE: You may press the HOLD/RET at any time during Day and Time setting to return to the normal display. 12 Hr. / 24 Hr. Time Format Your thermostat is set from the factory in normal 12 (AM / PM) time format. To change to 24 hour (military) time, press PROGRAM at any time while the Hour, Minute, or Day is flashing to toggle between the 12 hour and 24 hour formats. The AM / PM indicator will not be displayed in 24 hour mode. Both the current time and all programs will automatically change to the selected format. PROGRAMMING The following time and temperature settings are pre-programmed into the thermostat: M AM n All 7 days of the week have the same default programs. Personal Program Schedule instructions above to change the n You can revise the factory programs to match your own schedule. Use this position n Familiarize yourself with manually changing programs, so that you can easily modify the programs as your comfort needs change. Follow the steps below to change the program times and temperatures. NOTE: 1) The program time can be set in 10-minute increments. 2) The program temperature can be set in increments of 1°F (1°C). 3) After 15 seconds without a key press, the thermostat will r display mode. 4) When setting the program time, note the AM / PM indicator STEP 1: n Slide the System Switch to the HEAT or COOL position to program the corresponding system. NOTE: If the System Switch is in the OFF position, the last position used will be programmed. STEP 2: n Press to enter program mode. HEAT or COOL will be displayed on the LCD. STEP 3: n The Program hour and AM or PM indicator are flashing. Press to change the hour. STEP 4: n Press again to change to the minute position. The current minute will be flashing. n Press to change the minute. STEP 5: n Press again to change to the program temperature. The current temperature will be flashing. n Press to change the temperature. n Press again to move to the next program number. n Repeat Steps 3 through 5 to change the remaining Weekday and Weekend programs. (There are a total of 8 programs.) n After cycling through all 8 programs, press again to return the display to normal. n Press at any time to exit the Program Mode. repeatedly n Press and hol...

Эта инструкция также подходит к моделям:
Термостаты - 43157 (228.87 kb)
Термостаты - 43157 (228.87 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории