Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Fluke, модель 568

Производитель: Fluke
Размер: 675.81 kb
Название файла: 566_____umeng0200.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


°C and °F To toggle between °C (Celsius) and °F (Fahrenheit) measurements, press the Menu softkey until °C or °F appears as the left softkey function. Press the corresponding softkey to change between the measurements. Min, Max, Avg, Differential The thermometers can measure minimum (MIN), maximum (MAX), average (AVG), or differential (.) temperatures each time a reading is taken. These values are not shown if a thermocouple is plugged into the thermometer. To turn on the Min Max mode: 1. Press the Menu softkey until MnMx (Min Max) appears as the left softkey function. 2. Press the MnMx softkey. The display shows the present reading, maximum and minimum readings, and the emissivity setting. To turn on the Avg/Dif mode: 1. Press the Menu softkey until Avg appears as the right softkey function. 566/568 Users Manual 2. Press the Avg softkey. The display shows the present reading, average reading, the differential reading between max and min (designated by .), and the emissivity setting. Note Min, Max, Avg, and Differential readings are saved as part of the saved data when either Min/Max or Avg/Dif mode is enabled. Alarm The thermometers have a programmable high and low alarm to designate high or low readings depending on the thresholds entered. When the alarm level is reached, an alarm will sound and the display will flash orange and white. To set either the high or low alarm: 1. Press the Menu softkey until Alarm appears as the right softkey function. 2. Press the Alarm softkey to access the Alarm menu. 3. Press either the Hi or Lo softkey, depending on which alarm will be set. 4. Press the ON softkey to turn the alarm on. 5. Press the OFF softkey to turn the alarm off. 6. Use the Set softkey to access the Hi or Lo Alarm Set menu. 7. Use the down or up softkeys to change the alarm setting. 8. Once the desired settings have been entered, press the Done softkey. Trigger Lock The thermometer trigger can be locked on for continuous measurement. To lock the trigger: 1. Press the Menu softkey until the lock symbol (G) appears as the left softkey function. 2. Press the G softkey to lock the trigger. The lock symbol appears on the display to designate a locked trigger. When the trigger is locked, the G softkey changes to H. Press this softkey to unlock the trigger. Laser *WWarning To avoid injury, do not point the laser directly at eye or indirectly off reflective surfaces. The thermometer is equipped with a laser used for aiming purposes only. The laser turns off when the trigger is released. To enable or disable the laser: 1. Press the Menu softkey until Laser appears as the right softkey function. 2. Press the Laser softkey to enable or disable the laser. * appears on the display when the laser is enabled. Infrared Thermometers Menu Overview Setup From the Setup menu, the backlight, time and date, and display language can be changed. Backlight In normal use, the backlight is always on. Use this menu to change the backlight setting from on to off. Turning the backlight off conserves battery power. 1. Press the Menu softkey until Setup appears as the left softkey function. 2. Press the Setup softkey. 3. Backlight has an indicator next to it. To enter the backlight menu, press the Enter softkey. 4. Press the OFF softkey to turn the backlight off, press the ON softkey to turn it on. 5. Press the Back softkey to return to the Setup Menu. Time/Date To change the time on the thermometer: 1. Press the Menu softkey until Setup appears as the left softkey function. 2. Press the Setup softkey to enter the Setup menu. 3. Press the down arrow softkey to select Time/Date. 4. Press the Enter softkey. 5. Select the Time softkey. 6. Select the desired time format softkey (24hr or 12hr). 7. Use the up and down softkeys to change the selected hour to the desired hour. 8. Press the Next softkey to select the minutes. 9. Use the up and down softkeys to change the selection to the desired minute. 10. When in 12 hour mode, press the Next softkey to highlight the am/pm parameter. 11. Use the up and down softkey to change to am or pm. 12. Press the Done softkey when finished. The display reverts to the first page of the Time/Date menu. To change the date on the thermometer: 1. From the main menu, press the Menu softkey until Setup appears as the left softkey function. 2. Press the Setup softkey. 3. Press the down arrow softkey to select Time/Date. 4. Press the Enter softkey. 5. Press the Date softkey. 6. Select the date format: Day/Month/Year (dmy) or Month/Day/Year (mdy). 7. Use the up and down softkeys to change the selected parameter. 8. Press the Next softkey and the arrow softkeys to select the month, date, or year parameters. 9. Use the up and down softkeys to change the selected parameter. 566/568 Users Manual 10. Press the Next softkey to move through each parameter. 11. Press the Done softkey when finished. The display reverts to the beginning of the Time/Date menu. Language To change the displayed language: 1. From the main menu...

Эта инструкция также подходит к моделям:
Термостаты - 566 (675.81 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории