To activate the holiday program, perform the following: 1. Press the schedule button until the arrow is next to “holiday.” 2. The next day’s date will be displayed at the bottom of thescreen under the words “return on.” There will be a box Table 2 — Daily Schedule Planner DAY SCHEDULE OF THE WEEK Occ Occ2 Occ3 Unocc Start Time / Heat / Cool Start Time / Heat / Cool Start Time / Heat / Cool Start Time / Heat / Cool Monday / / / / / / / / Tuesday / / / / / / / / Wednesday / / / / / / / / Thursday / / / / / / / / Friday / / / / / / / / Saturday / / / / / / / / Sunday / / / / / / / / NOTE: The cooling temperature set point must be higher than the heating temperature set point. (The temperature difference may be changed in the advanced set up configuration by the installer.) 3 around the date. To set the date (D), press the up buttonand stop on the desired date. 3. If the month (M) needs to be changed, press the soft button under the month on the screen. The selection box will move to the month number. Press the up button to set thedesired month. 4. Repeat this process to change the year (Y), if necessary. 5. Press the done button. This will instruct the thermostat to begin the Holiday schedule immediately. 6. Close the thermostat door. Turning the Heating and Cooling System Off — To use the thermostat to turn the heating and cooling system off, perform the following: 1. Open the thermostat door. 2. Press the mode button until the display shows “off” in theupper left corner. 3. Close the thermostat door. Changing the Humidity Level — The thermostats offer three humidity options: normal, auto, and off. The thermostat is set at the factory for “normal humidify,” which is a fixed humidity setting based on how much humiditythe user wants in the space. This humidity level remains constant, regardless of the outdoor temperature. The user can manually adjust the humidity level according to their own preferences. The second option, “auto humidify,” uses an outdoor temperature sensor (if installed) to automatically adjust the indoorhumidity level according to the outside temperature. The third option is to turn off the humidify/dehumidifyfeature. To change the fixed (constant) humidity setting for normalhumidify, perform the following procedure: 1. Open the thermostat door. 2. The “humidify” icon will be displayed at the bottom of the screen when the operating mode is heat. The “dehumidify” will be displayed when the operating mode iscool. 3. Press the soft button under the humidify or dehumidify icons. The screen will display the current setting. NOTE: A humidify icon will only be shown for33CS2PPRH thermostats. 4. Press the up or down buttons to change the humidity setting. It is factory set at 26% for humidify and 60% for dehumidify. If there is too much condensation in the space, set the value to a lower number. If the air is too dry, set thevalue to a higher number. Humidity can be set to between10% and 46%. The dehumidify range is from 46% to98%. 5. Close the thermostat door. To change the humidity setting for auto humidify, performthe following procedure: 1. Open the thermostat door. 2. The “humidify” icon will be displayed at the bottom of the screen. Press the soft button under the humidify icon. The screen will display the current setting. NOTE: A humidify icon will only be shown for33CS2PPRH thermostats. 3. Press the mode button. An auto icon will appear at the topof the screen. The current humidity reading and the autohumidify set point will also be shown. The default autohumidify set point is 5. 4. Press the up or down button to change the auto humidifysetting number (1 through 9). If there is too much condensation on the windows, select a number lower than 5. If there seems to be a lot of static electricity, which often means the air is too dry, select a number higher than 5. 5. Close the thermostat door. To turn off the humidify or dehumidify feature open thethermostat door. Press the soft button under the humidify or dehumidify icons. Then press the mode button until the screendisplays OF. Close the themostat door. Using Emergency Heat — Emergency heat should beselected when it is desirable to heat the space with the auxiliaryheat only. To set the thermostat to use emergency heat, open the thermostat door. Press the mode button repeatedly until the arrowunder the button moves to the Em heat indicator on the screen. Close the thermostat door. Advanced Programming — The user can customize several features of the thermostat. See Table 3. Table 3 — Configuration Options OPTION NUMBER CONFIGURATION 01 Reset Reminders 02 Fahrenheit/Centigrade Selection 03 Backlighting 04 Keypad Lockout 05 Programmable/Nonprogrammable Selection 06 Number of Programming Periods 07 Unused 08 Daylight Savings Time RESET REMINDERS — The thermostat will display whenit is time to change the UV (ultraviolet) light, change the filter, or perform scheduled maintenance to the equipment. When thereminder icons are displayed on the screen, ...

Эта инструкция также подходит к моделям:
Термостаты - EDGE PRO 33CS2PP2S-01 (228 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории