Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Carrier, модель PROGRAMMABLE DIGITAL THERMOSTAT 53DFS250-FS

Производитель: Carrier
Размер: 430.17 kb
Название файла: 334470cb-eb18-46cc-832a-dc205b347219.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


2 I _,I |1|11A Sta [] __ "U U Pm ISt°p IIII [_SuMoTuWeThFrSa-Setup r_,,, w,_,,, -q Liquid Crystal Display with Thermoglew TM Backlight [_ un_ sled 123 _ o ,COOL, LOCKeaOverride [_ Up/Down Buttons []Mode Button [_ Outside [] F4] Override Button Fq Heat or Cool Indicator Heat = Red, Cool = Green _[_ _On_ ONOFFHEAT _[] [_Ternperature Sensor Bubble I1€1,'1_Bill [_ FRONT PANEL DISPLAY QUICK START Set BASIC OPERATION the clock and go 1 1 2 2 E_ Mode Indicators Selects the operation mode of the equipment. HEAT -indicates the heat mode. COOL -indicates the air conditioning mode. AUTO -indicates the system will automatically changeover between the heat and cool modes as the temperature varies. OFF -indicates the entire system is turned off. PROGRAM ON -indicates the stored program is enabled to run. See page 2. PROGRAMMING Occupied and Unoccupied Periods ADVANCED SETUP ABOUT ADVANCED FEATURES 3 4 r_ ['3-] Clock with of the WeekDay Indicates the current time and day. This used to program the timer periods. See Room Temperature Display Indicates the current room temperature. clock page is also 2. AND WARRANTY OPERATION 5 7 [4-] [5] Desired Set Temperature Indicates desired room temperature(s). See page 2. Override Indication Indicates the current program is currently being overridden for up to 4 hours. See pages 2 and 5. IMPORTANT: Followbefore proceeding. Installation Instructions E_] Occupied or Unoccupied Indication Indicates the program number: Occupied Unoccupied. See pages 3 and 4. 1,2, 3, or CAUTION: SETTHERMOSTATTO MODE "OFF" PRIOR TO CHANGING SETTINGSIN SETUPOR RESTORING FACTORY DEFAULTS, Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No 535-328 Printed in U.SA Form OM53-3 Pg 1 11-04 Replaces: New F_I Setup Indication indicates the thermostat See page 4. Indication Fan --indicates constant F'81Fan Operation - is in the programming mode. 3 Speed continuous 3 speed indicators appear as: 1 bar m = low speed 2 bars ml = medium speed 3 bars roll = high speed When Fan is not lit --indicates the fan operation. fan is in Auto mode. The fan will operate at the speed which will help meet room temperature conditions. See page 4. E_] Locked indication Locked appears after the right combination of buttons are pressed, rendering the buttons inoperative. See page 5. E_] Start/Stop indication Start or Stop appears when programming timer functions. See page 3. Eli Outside Indication Indicates the temperature displayed is from the optional outside sensor. See page 6. MODE S_ Press the Mode button. While hotdmg the Mode, press the Override button OVERRIDE O for2 Seconds to enterSetup screens, t2:OL1 _ Pm _ Press both Mode and MODE ( Override buttons as above to return to norma! operation. OVERRIDE During Setup and Programming: Pressing the Mode button selects different flashing items. (Repre sented in dark black). Pressing the Up and Down buttons wiil modify the flashing selection. To adjust the clock or Day use buttons. ) The thermostat is preprogrammed from the factory to operate without the need for further programming. To optimize the installation of this thermostat, follow the instructions in the Advanced Setup section, or in the Occupied/ Unoccupied periods section. NOTE: The thermostat is not programmed to operate heat pump systems. Select Mode The HEAT setting indicates the temperature the room has to reach before the unit will turn on to heat the room. _ _ _;# HEAT Sg The COOL setting indicates the temperature the room has to reach before the unit will turn on to cool the room. AUTO will automatically select heat or cool based on 72 room temperature demand. AUTO HEAT U Sg Program On will activate the stored timer operation. (Occupied and Unoccupied uno_upJed periods.) _ © COOL NE,M OFF indicates the system is turned off. OFF Select Desired Temperature In any mode, adjust the desired Set Point TerTiperature 77 with NEAT buttons. Pressing the up/down buttons in Auto mode will adjust both the heat and cool set point temperat_simultaneously. Pressing the up/down buttons in Heat or CooI modes will adjust only the heat or coot set point temperaTUre. Override Press OVERRIDE 0 I '*t • _"1tl _ =_.IU PrnStop 0_. s_ 03 unoccupied ocoo ProgramOn During programmed, unoccupied periods pressing the Override button will force the thermostat into Occupied 1 comfort settings, temporarily. With each successive push of the Override button, the override timer wilt add 30 min utes, until the maximum of 4 hours is reached. Then the next press will zero out the override timer, returning to unoccupied if there are no further button presses. When in Override, the Override icon and the Occupied 1 icon appear on the display. The time of day clock alternates with the time remaining in override. During Override, the set points are adjustable, provided the keypad is not locked. Page 2 Important i Before you Begin When using unoccupied modes, A...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории