6. FILTER CHANgE TIMER: You can set the filter reminder to prompt you when to check your furnace filter in 30 day increments from 30 to 360 days. Use the or buttons to adjust how often you want the reminder then press Next to move back to the begining of the advanced user options, or Done to return to the User/System selection screen. 44040-01 • 03/24/201038 ©2010 Hunter Fan Company 39 6 Advanced Menu User Options Features HomeMenuScheduleUse Away Period [ Yes] [ No] BackNextCancelDone5 HomeMenuScheduletimer for filter change reminder 'days' BackNextCancelDone6 90 ©2010 Hunter Fan Company 39 6 Advanced Menu User Options Features HomeMenuScheduleUse Away Period [ Yes] [ No] BackNextCancelDone5 HomeMenuScheduletimer for filter change reminder 'days' BackNextCancelDone6 90 6Features Advanced Menu System Options 6Features Advanced Menu System Options 1. Select [ system] in the message window and press Next to enter the system menu. 2. SYSTEM TYPE: Allows you to select the type of system you have. Conventional systems typically use a compressor outside for cooling and a seperate heating system inside, where as a heat pumps use the compressor outside for both heat and cool. If you are unsure of your system type, see “Technical Support” on page 52. Press either [conventl] or [heat pump] on the screen and choose Next to advance to the next option. 3. FURNACE TYPE: If you selected [conventl] on the previous screen, you will need to specify the type of furnace your system uses. Press either [gas/oil] or [electric] and choose Next to advance to the next option. Note: If you have a heat pump this setting should be [electric]. 4. SPAN 1: The next menu option is to set your thermostats primary span. The span setting allows you to adjust the system ON/OFF cycle rate. The default setting is 2F. The system cycles ON or OFF when the temperature is within 2°F (1°C) above and below the set temperature. The span setting can be adjusted if your system is cycling too fast or too slowly. Use the or buttons to adjust between 1, 2, or, 3. Press Next to advance to the next option. Note: Setting a higher SPAN number increases your cycle time by allowing the system to run longer; a lower number will decrease your cycle time by causing the system to run for a shorter length of time. 44040-01 • 03/24/201040 ©2010 Hunter Fan Company 41 6 Advanced Menu System Options Features HomeMenuSchedulestage one span BackNextCancelDone2 4 HomeMenuScheduleselect settings to edit [ user] [ system] NextCancel1 HomeMenuSchedulesystem type [ conventl] [ heat pump] BackNextCancelDone2 HomeMenuSchedulefurnace type [ gas/oil] [ electric] BackNextCancelDone3 ©2010 Hunter Fan Company 41 6 Advanced Menu System Options Features HomeMenuSchedulestage one span BackNextCancelDone2 4 HomeMenuScheduleselect settings to edit [ user] [ system] NextCancel1 HomeMenuSchedulesystem type [ conventl] [ heat pump] BackNextCancelDone2 HomeMenuSchedulefurnace type [ gas/oil] [ electric] BackNextCancelDone3 6Features Advanced Menu Options 6Features Advanced Menu Options 5. SPAN 2 : Unless you have a multi-stage conventional or heat pump system, there is no need to change the second stage span. If you do, use the or buttons to adjust between 1, 2, or, 3. Press Next once this has been changed or if you need to make no changes. Second stage span acts the same as your primary, but it determines when and how long your second stage heat runs. 6. Auto Season Span: When your thermostat is set to “Auto”, this setting allows the thermostat to switch between heat and cool modes based off the room temperature. The auto season span limits how close your heat and cool set temperatures can be to allow the thermostat to switch between the two modes properly. Use the or buttons to adjust between 3O to 6O. Press Next to advance to the next option. Example: If you set your heat temperature for a schedule to be 68O, the lowest you would be able to set your cool temperature for that schedule would be 73O, with an auto season span of 5. Assuming you have a stage 1 span of 2, see page 40 for stage 1 span description, a heating temperature of 68O, and a cooling temperature of 73O, your thermostat will activate heat at 67O and run till 69O and shut off. If the temperature continues to rise up to 74O, 1O above your cooling temperature, your thermostat will switch to cooling, run to 72O and then shut down. The thermostat will switch back to heating if the temperature drops to 67O, 1O below your heat temperature. 7. Temperature Calibration: If your thermostat seems to be running a degree or two hot or cold, you can set the calibration here. Use the or buttons to adjust between -2O to 2O. Press Next to advance to the next option. 44040-01 • 03/24/201042 ©2010 Hunter Fan Company 43 6 Advanced Menu System Options Features HomeMenuSchedulestage two span BackNextCancelDone2 5 HomeMenuScheduleauto season span BackNextCancelDone5 6 HomeMenuScheduletemperature calibration '+ or -from current temp' BackNextCancelDo...

Эта инструкция также подходит к моделям:
Термостаты - 44905 (8.36 mb)
Термостаты - 44905 (8.36 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории