DAY/HOUR/MIN— Set the day and clock settings. .. PGM—Program the schedule (programs). .. MODE—Select the operating mode. RETURN—To exit a function. .. To configure temperature setpoints: Comfort, Economy and Vacation. .. Adjust the floor temperature limit (AF only). .. —Increase and decrease temperature. .. —Indicates the number of the current program when Automatic mode is enabled. .. Current operating mode (auto / manual ). In Auto mode, the program’s associated setpoint icon is also displayed ( ). .. Indicates the room OR floor temperature. .. Heating indicators (see “Temperature Control” below). TH132-A This model has been designed to control a room’s ambient temperature. The TH132-A has one temperature sensor located in the control module. TH132-AF This model is designed to use a floor sensor to control the room temperature. The TH132-AF has two temperature sensors: • The first one, installed in the control module, controls the ambient temperature. • The second one, installed in the floor (and connected to the power base), limits the temperature of the floor (the default setting of this limit is 82°F). TH132-F This model is designed to control floor heating systems. The TH132-F has one temperature sensor installed in the floor (sensor is connected to the power base). Control Module TH132 A/F/AF Owner’s Guide TH132 Description Models Overview The TH132 has two switches, located on the upper-left part on the rear of the control module, which are used to set the following options: Early Start When the Early Start function is enabled (disabled by default), the TH132 calculates the optimum system start time to obtain the desired temperature by the set time. To enable this function: .. Position switch #1 down. Note: When this function is enabled, the system can be activated before the program’s start time. Temperature Display By default, the TH132 displays the temperature in °C. If you wish to change to °F: .. Position switch #2 up. Note: When you switch from °C to °F or vice versa, the , and setpoints must be redefined. Configure the Switches Align the bracket tabs on the control module with the holes located on top of the power base. This control module must be installed on a PB130 series power base. Note: Keep the thermostat's air vents clean and free from obstructions. Note: The screw cannot be removed On the first installation, the screen displays: 0:00, MO, and temperature (room/floor). For Floor Heating Installations: One of the two following messages may be displayed when a problem occurs: LO: The floor temperature is below 32°F (0°C), or the temperature sensor is defective, or not connected. The heating indicator is displayed and the relay is closed (energized). HI: The floor temperature is above 140°F ( 60°C) , or the temperature sensor is defective. .. Set the time (HOUR - MIN) . .. Set the day (DAY). If you remove the from its base for more 2 hours, the time and day will have to be reprogrammed. Comfort and Economy Setpoints These setpoints are associated with the schedule’s programs (prog. 1 & 3 = Comfort, prog. 2 & 4 = Economy) and are preprogrammed as follows: .. A & AF models— 68°F, 64°F .. F model— 82°F, 68°F To modify a setpoint: .. Set the temperature using and press and hold the or button until it is displayed on the screen. .. Press MODE/RETURN to exit. Vacation Setpoint The vacation setpoint is associated to the Vacation operating mode and is preprogrammed to 50°F. To modify this setpoint, repeat above steps. Floor Temperature Setpoint (AF model only) The floor temperature limit is preprogrammed to 82°F to avoid damage to your floor. To modify, press the adjustment button (below ) using a pointed object, set the desired temperature using and press MODE/to exit. The TH132 offers three operating modes: Automatic — Executes the schedule. .. Press MODE to select . The current program number is displayed. You can temporarily bypass the current program by setting a specific temperature setpoint or by selecting one of the pre-defined setpoint buttons ( ) . The new setpoint will be maintained until the beginning of the next program. Manual —Maintains a constant temperature. .. Press MODE to select . .. Set temperature or select one of the predefined setpoint buttons ( ) . Vacation —Maintains the Vacation setpoint during a prolonged absence. .. Press . Install the Control Module Power base Control module Air vents Air vents First Power ON Set the Time and Day Adjust the Temperature Setpoints Select the Operating Mode 400- 132- 000- A The schedule is used with the Automatic mode. The schedule controls the heating system to automatically switch between the Comfort and Economy temperature setpoints at the times you have programmed. The schedule consists of 4 programs per day defined as follows: To enter the programs’ start time To shorten programming, you simply have to enter the start time for each program. .. Press PGM. .. Press DAY to select the day (hold for 3 seconds to select all days of the ...