Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации Mamiya, модель Econotig

Производитель: Mamiya
Размер: 1.2 mb
Название файла: o303t_mil.pdf
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, norme NFPA 51B, de la National Fire Protection Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269.9101 (telephone : (617) 770.3000, site Web : et OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, de l’U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (il y a 10 bureaux regionaux . Telephone pour la Region 5, Chicago : (312) 353.2220, site Web : 2-5. Information sur les champs electromagnetiques Donnees sur le soudage electrique et les effets des champs magnetiques basse frequence sur l’organisme En parcourant les cables de soudage, le courant cree des champs electromagnetiques. Les effets potentiels de tels champs restent preoccupants. Cependant, apres avoir examine plus de 500 etudes qui ont ete faites pendant une periode de recherche de 17 ans, un comite de specialistes du National Research Council a conclu : « L’accumulation de preuves n’a pas demontre que l’exposition aux champs magnetiques etaux champs electriques a haute frequence constitue un risque pour la sante humaine ». Toutefois, les etudes et l’examen des preuves se poursuivent. En attendant les conclusions finales de la recherche, il serait souhaitable de reduire l’exposition aux champs electromagnetiquespendant le soudage ou le coupage. Afin de reduire les champs electromagnetiques en milieu de travail, respecter les consignes suivantes : 1. Garder les cables ensemble en les torsadant ou en les fixant avec du ruban adhesif. 2. Mettre tous les cables du cote oppose a l’operateur. 3. Ne pas s’enrouler les cables autour du corps. 4. Garder le poste de soudage et les cables le plus loin possible de soi. 5. Placer la pince de masse le plus pres possible de la zone de soudage. Consignes relatives aux stimulateurs cardiaques : Les personnes qui portent un stimulateur cardiaque doivent avant tout consulter leur medecin. Si ce dernier les declare aptes, il leur est recommande de respecter les consignes ci-dessus. OM-303 Page 8 OM-303 Page 9 SECTION 3 . DEFINITIONS 3-1. General Precautionary Label 3-2. Symbols And Definitions Tig Welding Remote Foot/Hand Control Stick Welding High Temperature Output Alternating Current Direct Current On Electrode Positive Electrode Negative Do Not Switch Under Load Voltage Input A Amperes Off Electrode Gas Out Amperage Control/ Panel Work Remote V Volts U0 Rated No Load Voltage (Average) U2 Conventional Load Voltage X Duty Cycle I1eff Maximum Effective Supply Current I1max Rated Maximum Supply Current I2 Rated Welding Current IP Degree Of Protection 1 1 Single-Phase Combined AC/DC Power Source Percent U1 Primary Voltage Line Connection Hz Hertz SECTION 4 . INTRODUCTION 4-1. Included with Your Unit 1 12 ft (3.7 m) Work Cable and Clamp 2 150 Amp TIG Torch with 12-1/2 ft (3.8 m) Cord and Flow-Through Quick-Connect (50 Hz models come with 25 ft (7.6 m) TIG Torch) 6 3 Electrode Holder and Quick-Connect 4 Gas Hose 5 Gas Regulator (Not included with 50 Hz models) 6 “How-To” DVD 7 RFC-14 Foot Control with 20 ft (6 m) Cord (60 Hz models only. 50 Hz models come with RCC-14 fingertip control instead.) 8 8 ft (2.4 m) Primary Cord (Plug supplied with 230 Volt model only) . Some assembly is required. For options and accessories see back of book or contact your distributor. 7 2 3 5 8 1 OM-303 Page 10 4-2. Specifications A. 60 Hertz Models Rated Output at 20% Duty Welding Amperage Range Max. Rated Output KVA KW Dimensions Net Cycle AC High AC Low DC OCV Weight TIG: (GTAW) 150 A at 15 VDC 150 A at 15 VAC 50.165 20.50 30.160 78 7878 200 V.60 A (3.6)* 0)*230V 230V230V . .. 52 A (3 52 A (352 A (3 .0)* 460 V.33 A (1.5)* 12.0 64)*(0 (0(0 .64)* 5.4 3)*(0 (0(0 .3)* H: 18 in (457 mm) 13 in (330 mm)W WW : :: 13 in (330 mm) D: 251/2 in (648 mm) 140 lb (64 kg)(64 kg) Stick: (SMAW) 130 A at 25 VDC 150 A at 25 VAC 35.165 20.50 25.130 * () While idling. B. 50 Hertz Models Rated Output at 20% Duty Welding Amperage Range Max. Rated Output KVA KW Dimensions Net Cycle AC High AC Low DC OCV Weight TIG: 150 A at 15 VDC 50.165 20.50 30.160 (GTAW) 150 A at 15 VAC 380 V.39 A (2.0)* 14.8 6.7 H: 18 in (457 mm) 140 lb 78 415 V.36 A (1.5)* (0.64)* (0.3)* W: 13 in (330 mm) D: 251/2 in (648 mm) (64 kg)(64 kg) Stick: (SMAW) 130 A at 25 VDC 150 A at 25 VAC 35.165 20.50 25.130 * () While idling. 4-3. Duty Cycle Chart 2 Minutes Welding 8 Minutes Resting Duty cycle is percentage of 10 minutes that unit can weld at rated load without overheating. Exceeding duty cycle can damage unit and void warranty. GTAW: 20% Duty Cycle at 150 A AC/DC SMAW: 20% Duty Cycle at 130 A DC, or 150 A AC ST-157 648-A 4-4. Volt-Ampere Curves Volt-amperecurves show minimum and maximum voltage and amperage output capabilities of welding power source. Curves of other settings fall between curves shown. ss...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории