Производитель: Lincoln Electric
Размер: 56.64 kb
Название файла: 41ae9610-3793-4709-932c-2f06355f88f0.pdf
|
Фрагмент инструкции
October 1988 SECTION I - IDENTIFICATION Manufacturer/ Supplier: The Lincoln Electric Company 22801 St. Clair Avenue Cleveland, OH 44117-1199 (216) 481-8100 Product Type: Covered Electrode Classification: AWS ENiCrMo-6 SECTION II - HAZARDOUS MATERIAL (1) I M P O R T A N T ! This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal use of this product are covered by Section V; see it for industrial hygiene information. CAS Number shown is representative for the ingredients listed. All ingredients listed may not be present in all sizes. (1) The term “hazardous” in “Hazardous Materials” should be interpreted as a term required and defined in the Hazards Communication Standard and does not necessarily imply the existence of any hazard. All materials are listed on the TSCA inventory. Ingredients: CAS No. Wt.% TLV mg/m3 PEL mg/m3 Chromium and chromium alloys or compounds (as Cr)***** 7440-47-3 10 0.5(b) 1.0(b) Limestone and/or calcium carbonate 1317-65-3 10 10 15 Molybdenum alloys (as Mo) 7439-98-7 5 10 10 Iron 7439-89-6 < 5 10* 10* Silicates and other binders 1344-09-8 < 5 10* 10* Fluorides (as F) 7789-75-5 < 5 2.5 2.5 Manganese and/or manganese alloys and compounds (as Mn)***** 7439-96-5 < 5 0.2 1.0(c) Niobium alloys (as Nb) 7440-03-1 < 5 10* 10* Tungsten alloys and compounds (as W) 7440-33-7 1 5 5 Mineral silicates 1332-58-7 0.5 5** 5** Silicon and/or silicon alloys and compounds (as Si) 7440-21-3 0.5 10* 10* Titanium dioxides (as Ti)***** 13463-67-7 < 0.5 10 15 Titanium and/or titanium alloys (as Ti) 12719-90-3 < 0.5 10* 10* Aluminum and/or aluminum alloys (as Al)***** 7429-90-5 < 0.5 10 15 Nickel core wire***** 7440-02-0 55 1.5 1 Supplemental Information: (*) Not listed. Nuisance value maximum is 10 milligrams per cubic meter. PEL value for iron oxide is 10 milligrams per cubic meter. TLV value for iron oxide is 5 milligrams per cubic meter. (**) As respirable dust. (*****) Subject to the reporting requirements of Sections 311, 312, and 313 of the Emergency Planning and Community Right-to-Know Act of 1986 and of 40CFR 370 and 372. (b) The OSHA PEL for chromium (VI) is 5 micrograms (0.005 milligrams) per cubic meter. The TLV for water soluble chromium (VI) is 0.05 milligrams per cubic meter and the TLV for insoluble chromium (VI) is 0.01 milligrams per cubic meter. (c) Values are for manganese fume. STEL (Short Term Exposure Limit) is 3.0 milligrams per cubic meter. Values are those proposed by OSHA in 1989. Present PEL is 5.0 milligrams per cubic meter (ceiling value). SECTION III - HAZARD DATA Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See Z49.1 referenced in Section VI. Product is inert, no special handling or spill procedures required. Not regulated by DOT. Rev 11/06b (CONTINUED ON SIDE TWO) Product: Blue Max Nyloid 2 Date: 2/1/04 SECTION IV - HEALTH HAZARD DATA Threshold Limit Value: The ACGIH recommended general limit for Welding Fume NOS - (Not Otherwise Specified) is 5 mg/m3. ACGIH-1999 preface states that the TLV-TWA should be used as guides in the control of health hazards and should not be used as fine lines between safe and dangerous concentrations. See Section V for specific fume constituents which may modify this TLV. Threshold Limit Values are figures published by the American Conference of Government Industrial Hygie...
Эта инструкция также подходит к моделям:Сварочные аппараты - METALUX EIM 248 (56.64 kb)
Сварочные аппараты - METALUX EIM 296 (56.64 kb)