Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Cobra Electronics, модель CPI 1000

Производитель: Cobra Electronics
Размер: 1.5 mb
Название файла: 86614f55-a5be-dde4-b96e-5e8ac10f6212.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


480-399-P Version C Nothing Comes Close to a Cobra® For more information or to order any of our products, please visit our website: The Cobra line of quality products includes: CB Radios microTALK® Radios Radar/Laser Detectors Safety Alert® Traffic Warning Systems Mobile GPS Navigation Systems HighGear® Accessories CobraMarine® VHF Radios CobraMarine® Chartplotters Power Inverters Accessories 10274_CPI1000_vC 8/14/07 3:48 PM Page 4 25Nothing Comes Close to a Cobra™A3A2 Product Features IconsSecondary IconsSecondary IconsSecondary IntroOperationCustomerAssistanceWarrantyNotesNoticeMain Button Remote On/Off Switch Jack AC Outlets Positive Battery Cable Terminal (Red) Negative Battery Cable Terminal (Black) Cooling Fan Contents Introduction Our Thanks to You . . . . . . . . . . . . . . . . . . A1 Customer Assistance . . . . . . . . . . . . . . . . A1 Product Features . . . . . . . . . . . . . . . . . . . A2 Important Safety Information . . . . . . . . . . . 1 Quick Evaluation Before Installation . . . . . . .4 Installation Installation Requirements . . . . . . . . . . . . . . 6 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Connecting Cables . . . . . . . . . . . . . . . . . . . 8 Power Consumption . . . . . . . . . . . . . . . . . 12 Ground Wiring . . . . . . . . . . . . . . . . . . . . . 13 Operation Turning Your Inverter On or Off . . . . . . . . 14 Remote On/Off Switch . . . . . . . . . . . . . . . 15 Operating Indicators . . . . . . . . . . . . . . . . . 16 Operating Limits . . . . . . . . . . . . . . . . . . . . 19 Troubleshooting Guide . . . . . . . . . . . . . . . 20 Specifications . . . . . . . . . . . . . . . . . . . . . . 21 Warranty Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Customer Assistance Maintenance . . . . . . . . . . . . . . . . . . . . . . . .23 Product Service . . . . . . . . . . . . . . . . . . . . 23 Accessories and Order Form . . . . . . . . . . 24 Features: • Two AC Receptacles • Voltage & Power Meter • Remote On/Off Capable • Automatic Thermal Protection/Shutdown • Reverse PolarityProtection • Low Battery Alarm • Low Battery Shutdown Voltage Input & Power Output Indicators USB Outlet Chassis Ground Terminal Output End Input End oOperationCustomerAssistanceWarrantyNotesNoticeonsCautionWarningInstallation1Nothing Comes Close to a Cobra™ IconsSecondary Important Safety Information Important Safety Information • Before installing and using your Cobra power inverter, please read these general precautions and warnings. Caution and Warning Statements To make the most of this inverter, it must be installed and used properly. Please read the installation and operating instructions carefully before installing and using it. Special attention must be paid to the CAUTION and WARNING statements in the manual. CAUTION Statements specify conditions which could cause damage to the unit or other equipment. WARNING Statements identify conditions that could result in personal injury or loss of life. General Precautions 1. Never install the inverter in a boat’s engine compartment where gas and battery fumes are present. 2. Do not operate the inverter if it has been dropped or damaged in any way. 3. Do not open the inverter; it contains no user- serviceable parts. Attempting to service unit could cause electrical shock. NOTE Internal components remain charged after all power is disconnected. 4. Do not expose the inverter to rain, snow, bilge water or spray. 5. Do not obstruct the ventilation openings. 6. Do not install the inverter in zero-clearance compartment. CAUTION This inverter should be used in negative ground applications only. IntroOperationCustomerAssistanceWarrantyNotesNoticeMain CPI1000_vC 8/14/07 3:48 PM Page 1 oOperationCustomerAssistanceWarrantyNotesNoticeonsCautionWarningInstallation1Nothing Comes Close to a Cobra™ IconsSecondary Important Safety Information Important Safety Information • Before installing and using your Cobra power inverter, please read these general precautions and warnings. Caution and Warning Statements To make the most of this inverter, it must be installed and used properly. Please read the installation and operating instructions carefully before installing and using it. Special attention must be paid to the CAUTION and WARNING statements in the manual. CAUTION Statements specify conditions which could cause damage to the unit or other equipment. WARNING Statements identify conditions that could result in personal injury or loss of life. General Precautions 1. Never install the inverter in a boat’s engine compartment where gas and battery fumes are present. 2. Do not operate the inverter if it has been dropped or damaged in any way. 3. Do not open the inverter; it contains no user- serviceable parts. Attempting to service unit could cause electrical shock. NOTE Internal components remain charged after all power is disconnected. 4. Do not expose the inverter to rain, snow, bilge water or spray. 5. Do not obstruct the...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории