Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Lincoln Electric, модель IDEALARC IM318-B

Производитель: Lincoln Electric
Размер: 654.67 kb
Название файла: 02092821-cba9-43f5-b0d8-b8df6ecdade9.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


boards, remove the upper box before working on this equip-case panel on the left side of the machine. The ment. names are printed on the boards. • Do not touch electrically hot parts. Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) POSSIBLE CAUSE REMEDY Input contactor (CR1) chatters. Machine input contactor does not operate. Machine input contactor operates but no output when trying to weld. Machine has maximum output but no control. Machine does not have maximum output. Machine has output but trips off immediately. a. Faulty input contactor (1CR). b. Low line voltage. c. Faulty pilot relay (2CR). a. Supply line fuse blown. b. Contactor power circuit dead. c. Broken power lead. d. Wrong input voltage. e. Primary or power SCR thermostats open. f. Open input contactor coil. g. Faulty on-off switch. h. Faulty pilot relay (2CR). a. Electrode or work lead loose or broken. b. Open main transformer (T5) primary or sec- ondary circuit. c. “Firing Circuit” P.C. board not connected or is faulty. d. Output pilot relay (6CR) not operating or faulty. a. “Output Control” switch (SW4) in wrong position. b. “Output Control” switch faulty. c. Open in feed back circuitry. d. Faulty “Control/Fault Protection” or “Firing Circuit” P.C. boards. e. Output control potentiometer open (lead no. 75). a. One input fuse blown. b. One phase of main transformer open. c. Faulty “Control/Fault Protection” or “Firing Circuit” P.C. boards. d. Output control potentiometer defective. e. Output control potentiometer leads open 226, 237, 236, 73, 74, 76, 77. a. Machine has either an internal or external short circuit on the output. b. Faulty “Control/Fault Protection” P.C. board. c. Machine output voltage applied to control leads. a. Repair or replace. b. Check with power company. c. Replace relay. a. Replace if blown. Look for reason first. b. Check pilot transformer T1 and associated leads and 5 amp fuse. c. Check input voltage at contactor. d. Check voltage against nameplate. e. Check for overheating. Make sure both fans are operating and there is no obstruction to free air flow. Faulty thermostats — replace. f. Replace coil. g. Replace switch. h. Replace relay. a. Repair connection. b. Repair. c. All nine light emitting diodes (L1 thru L9) must be lit. (See “P.C. Board Troubleshooting Guide”.) d. Check relay by connecting a jumper across termi- nals 2 and 4 on DC-1500 terminal strip. Replace if faulty. a. Check position of switch. b. Check switch and replace if faulty. c. Check wiring and control and “Firing Circuit” P.C. board wiring harness plugs. d. All light emitting diodes must be lit, except L4 on “Control/Fault Protection” board. (See “P.C. Board Troubleshooting Guide.”) e. Check and replace if faulty. a. Check and replace if blown after checking for rea- son for blown fuse. b. Check for open and repair. c. All light emitting diodes must be lit on both P.C. boards, except L4 on “Control/Fault Protection” board. (See “P.C. Board Troubleshooting Guide.”) d. Check and replace if faulty. e. Check and repair broken leads. a. Check internally and externally for any shorts and remove or repair. b. If no short circuits, LED L4 must be lit (See “P.C. Board Troubleshooting Guide”). c. Check control cable or wire feeder for shorted or grounded control leads. CAUTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353. -12 TROUBLESHOOTING GUIDE PROBLEMS (SYMPTOMS) POSSIBLE CAUSE REMEDY Variable or sluggish welding arc. a. b. c. Poor work or electrode connection. Welding leads too small. Welding current or voltage too low. a. b. c. Check and clean all connections. Check table on page 4. Check procedures for recommended settings. Machine will not shut off. a. b. Input contacts frozen. Pilot relay contacts stuck closed. a. b. Check for approximately .13 inch over travel of contacts. Check and replace if necessary. Output control not functioning on the machine. a. b. c. d. e. “Output Control” switch in the wrong position. Faulty output control switch. Faulty “Output Control” rheostat. Leads or connections open in “Control Circuit”. Faulty “Firing Circuit” or “Control/Fault Protection” P.C. board. a. b. c. d. e. Place switch in “Output Control at DC-1500”. Check and replace if found faulty. Check and replace if found faulty. Check lead continuity and connections for an open and repair if necessary. All light emitting diodes must be lit on both P.C. boards, except L4 on “Control/Fault Protection” board. (See “P.C. Board Troubleshooting Guide.”) Output control not functioning on remote control. a. b. c. d. e. “Output Control” switch in the wrong position. Faulty output control switch. Faulty remote control rheostat. Leads or connections open in “Control Circuit”. Faulty “Firing” or “Control/Fault Protection” P.C. board...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории