Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации GE, модель DBLR333GG

Производитель: GE
Размер: 228.81 kb
Название файла: f17eaa82-c437-4e4c-96ee-4fcdbb0e124b.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Extra-Large Capacity Gas Dryer Dimensions and Installation Information (in inches) Exhaust Option: When viewed from the front of the unit, exhaust 3-way via rear, left and bottom. Dryer is shipped exhausted to the rear. Alternate exhausting knockouts are supplied. Gas: An individual, properly-grounded branch circuit, with a three-prong grounding- type receptacle, protected by a 15 or 20 amp circuit breaker or a time-delay fuse is required. Gas Dryer Electric Rating: 120V, 60Hz, 6A Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply requires a conversion kit. Check installation instructions for correct kit and have a qualified gas technician install a conversion kit. See dryer ducting information for proper installation. Note: Dryer wall outlet must be located within 36" of service cord entry and accessible when dryer is mounted in position. Installation Information: For complete information, see installation instructions packed with your dryer. For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. 36 42 27 2 5-1/2 2-1/2 25-1/2* Side View Rear View 4-3/4 25-3/423-1/2 11-3/4 *24-1/2" from the edge of the side panel to the front. 25-1/2" from the front edge of endcaps. Power Cord Locations 5 Power Cord Hole 4-1/2 Back View Listed by Underwriters Laboratories Specification Revised 9/07 370218 DBLR333GG GE® 5.8 Cu. Ft. Extra-Large Capacity Gas Dryer For complete information, see installation instructions packed with your dryer. Ducting Materials: For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If “all rigid metal” duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the maximum recommended duct length. Exhaust Length Calculation: 1.Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn. 2.The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. The maximum length for flexible ducts are less than for rigid duct. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow. Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside. Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4" opening dampered wall cap. For more information on venting kits and accessories, please call 1-800-GE-CARES. Special Installation Requirements Alcove or Closet Installation: • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be exhausted to the outside. • Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side; 3" front and rear • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”. • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • No other fuel-burning appliance shall be installed in the same closet with a gas dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors. • The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223. Minimum Clearances other than Alcove or Closet Installation: • Minimum clearances to combustible surfaces are: 0" both sides; 3" rear Dryer Exhausting Information: Use metal duct only, vertical and horizontal ducting. Specification Revised 9/07 370218 DBLR333GG GE® 5.8 Cu. Ft. Extra-Large Capacity Gas Dryer Features and Benefits • 5.8 Cu. Ft. Extra-Large Capacity -Handles large-size items and family size loads • DuraDrum™ -Provides long-lasting dependability and durability • Three Heat Selections -Offer a choice of drying temperatures for better fabric care • Three Dry Cycles -Simple options for the reliable drying performance • Auto Dry -Uses thermostat...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории