Войти:
Оценок - 1, средний балл: 5 ( )

Инструкция по эксплуатации Henny Penny, модель HHC-993

Производитель: Henny Penny
Размер: 335.55 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


PROBE CLIP (OPTIONAL) The probe clip is an accessory, that may be ordered as an option, to hold the food probe when not in use. Remove one of the module screws and mount the probe clip with that screw. See photo at left. The food probe is accessed easier if the clip is mounted on the side of the unit that the door opens. See photo below. Probe Clip Mount clip here. 303 2-5 Model HHC-990 SECTION 3. OPERATION SECTION 3. OPERATION 3-1. INTRODUCTION This section provides explanations of all controls, along with operating procedures and daily maintenance. Read the Introduction, Installation and Operation Sections before operating the unit. 3-2. OPERATING CONTROLS Fig. Item No No. Description Function 3-1 1 POWER Switch A rocker switch that sends electrical current to the operating components when turned on 3-1 2 Temperature LED Lights when the control calls for heat, and the unit should start heating; it goes out once the temperature inside the cabinet reaches the programmed temperature setting Press the TEMPERATURE Button to set the cabinet temperature 3-1 3 Digital Display Shows the cabinet temperature, humidity settings, and the selections in the Program Mode; the temperature of the cabinet is shown by pressing the INFO button; if the temperature exceeds 300 °F (149°C), the display reads “E-5”, TOO HOT”. 3-1 4 Humidity LED Lights when the control calls for humidity; it goes out once the humidity inside the cabinet, reaches the programmed humidity setting Press the HUMIDITY button to set the relative humidity inside the cabinet, and to choose between the Proofing and Holding Modes, when the unit is turned on 3-1 5 Press to view the food probe temperature, cabinet temperature and humidity, date and time; if pressed in the Program Mode, shows previous settings; pressing this along with accesses the Information Mode which has historic information on the cabinet’s performance 3-1 6&7 Used to adjust the value of the currently displayed setting in the Program Mode 3-1 303 Model HHC-990 3-2. OPERATING CONTROLS (Continued) 3-1 8 Used to access the Program Modes; once in the Program Mode, it is used to advance to the next parameter; pressing this along with accesses the Information Mode which has historic information on the cabinet’s performance 3-1 9 Food Probe After plugging the food probe into the receptacle, the meat probe Receptacle can then be inserted into the product and the product temperature is displayed 3-1 10 Count Down Once a tray of food is placed in the cabinet, the appropriate timer Timers is pressed, and the time remaining shows in the display above the timer number; once the timer counts down to zero, the display flashes “0:00”, and the control beeps; the HHC-990 and 996 have 15 timers, and the HHC-993 and 998 have 5 timers 303 3-2 Model HHC-990 3-2. OPERATING CONTROLS (Continued) Control Decal 1 2 3 4 5 6 7 8 9 10 Figure 3-1 3-3 303 Model HHC-990 3-3. START-UP Before using the humidified holding cabinet, thoroughly clean the unit as described in the Cleaning Procedures Section of this manual. 1. Plug unit into electrical receptacle, or turn on wall circuit breaker. With the POWER switch turned to OFF the display shows “POWER OFF.” With the POWER Switch off, the display may show “PURGING”. This means the humidity has reached 95% inside the unit and the fan runs to help drop the humidity. Once the humidity reaches 92%, “POWER OFF” again shows in the display. Even though POWER switch is OFF it does not disconnect all electrical supplies to the controls. Unplug power cord, or turn off wall circuit breaker before servicing any electrical components, or electrical shock could result. 2. Turn the POWER switch to ON, and the display shows “PUSH TO PROOF”. 3. If the unit is to be used as a proofer, (80-140o F) (27-60o C), press the HUMIDITY button within 10 Slot seconds, while thedisplay still shows “PUSH TO PROOF”. If not, allow unit to heat normally, (140o-210o F) (60o-99o C). 4. Open door of unit and pour up to 3 gallons of water into bottom water pan, (minimum 1 gallon) up to the slot on the concentration ring. See figure 3-2. Figure 3-2 Do not overfill the water pan, or water could over flow and spill onto the floor, and personal injury could result. 303 3-4 Model HHC-990 3-3. START-UP(Continued) 5. Press the TEMPERATURE button to set the desired cabinet temperature. While the LED is flashing, press the UP and DOWN buttons until the desired temperature shows in the display. 6. Press the HUMIDITY button to set the desired cabinet humidity (OFF to 90%). While the LED is flashing, press the UP and DOWN buttons until the desired temperature shows in the display. 7. Allow the unit to preheat for about 1 hour prior to placing product in the cabinet. This allows the interior conditions to stabilize. 3-4. OPERATION WITH 1. The LEDs above the TEMPERATURE and HUMIDITY PRODUCT buttons go out when the desired temperature and humidity are reached inside the cabinet. Place hot product on pan and slide pan onto the ra...

Эта инструкция также подходит к моделям:
Сушильные машины - HHC-990 (335.55 kb)
Сушильные машины - HHC-992 (335.55 kb)
Сушильные машины - HHC-996 (335.55 kb)
Сушильные машины - HHC-997 (335.55 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории