Инструкция по эксплуатации Kenmore, модель ELITE 110.9587

Производитель: Kenmore
Размер: 2.3 mb
Название файла:
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


*6_A,, (15.9 cm) / A. Y2"NPT gas supply line B. %" NPT dryer pipe *NOTE: If the dryer is mounted on a pedestal, the gas pipe height must be an additional 14" (38.86 cm) from the floor. Burner input requirements Elevations up to 10,000 ft (3,048 meters): • The design of this dryer is certified by CSA International for use at altitudes up to lg,000 ff (3,048 m) above sea level at the B.T.U. rating indicated on the model/serial number plate. Burner input adjustments are not required when the dryer is operated up to this elevation. Elevations above 10,000 ft (3,048 meters): • When installed above 10,000 ft (3,048 m) a 4% reduction of the burner B.T.U. rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation. Gas supply pressure testing • The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than _/2psi. Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or fire. WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. 4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE TM venting products are recommended and are available from your local Sears store or Sears Service Center. DURASAFE TM vent products can be purchased from your dealer. For further information, please call 1-800-4-MY-HOME ® (1-800-46g-4663) or visit our Internet site at: • The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, or a concealed space of a building. • Do not use an exhaust hood with a magnetic latch. • Do not install flexible metal vent in enclosed walls, ceilings or floors. • Use clamps to seal all joints. Exhaust vent must not be connected or secured with screws or other fastening devices which extend into the interior of the duct. Do not use duct tape. IMPORTANT: Observe all governing codes and ordinances. Improper venting can cause moisture and lint to collect indoors, which may result in: • Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc. • Housecleaning problems and health problems. _TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. Use a heavy metal vent. Do not use plastic or metal foil vent. Rigid metal vent is recommended to prevent crushing and kinking. Flexible metal vent must be fully extended and supported when the dryer is in its final position. Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance. An exhaust hood should cap the vent to prevent rodents and insects from entering the home. Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, etc.). If using an existing vent system, clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint. Replace any plastic or metal foil vent with rigid metal or flexible metal vent. Typical exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible. B ..................... C ............. F .................... G A Dryer B. Elbow C. Waft D. Exhaust hood E. Clamps E Rigid metal or flexible metal vent G. Vent length necessary to connect elbows H. Exhaust outlet Optional exhaust installations This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted. Fire Hazard Cover unused exhaust holes with one of the following kits: 279818 (white) 279915 (graphite) 279925 (biscuit) Contact your local dealer. Failure to follow these instructions can result in death, fire, electrical shock, or serious injury. AB C A. Standard rear offset exhaust installation B. Left or right side exhaustinstallation C.Bottom exhaust installation (Not an optionwith pedestal installations.) Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer's instructions. I ii L L _== // is I /l 1 AB A. Over-The-Top installation (also available with one offset elbow) B. Periscope installation NOTE: The following kits for close clearance alternate installations are available for purchase. For further information, please call f-8OO-4-M.-HOME e (1-800-469-4663). • Over-The-Top Installation: Part Number 26-49900 lO Periscope Installation (For use with dryer vent to wall vent mismatch): Part Number 26-49901 -Less than 5" (12.7 cm) mismatch Part Number 26-49998 -5" (12.7 cm) to 18" (45.72 cm) mismatch Part Number 26-49904 -18" (45.72 cm) to 29" (73.66 cm) mismatch Part Number 26-49995 -29" (73.66 cm) to 50" (127 cm) mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncom...

Эта инструкция также подходит к моделям:
Сушильные машины - ELITE 110.9586 (2.3 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории