Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации GE, модель RDE400AW

Производитель: GE
Размер: 1.1 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


This includes the foam base and all adhesive tape holding the dryer accessories inside and outside. 2. Inspect and remove any remains of packaging, tape or printed materials before using the dryer. English Exhaust System Connections Requirements and Instructions 1. Do not use plastic flexible duct to exhaustthe dryer. Excessive lint can build up inside system and create a fire hazard and restrict air flow. Restricted airexhaust flow will increase dryer times. If your present system is made up of plastic duct or metal foil duct, replace it with a rigid or flexible metal duct. Ensure present duct is free of any lint prior to installing dryer duct. 2. If the dryer is not exhausted out doors, some fine lint will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard. To reduce risk of fire, dryer MUST BE EXHAUSTED OUTDOORS. 3. Do not allow combustible material (for example: clothing, draperies/curtains, paper) to come in contact with venting system. The dryer must not be exhausted into a chimney, a wall, a ceiling, or any concealed space of a building which can accumulate lint, resulting in a fire hazard. 4. Exceeding the length of duct pipe or number of elbows allowed in the "Maximum Length" charts can cause an accumulation of lint in the exhaust system. Plugging the system could create a fire hazard, as well as increase drying times. 5. Do not screen the exhaust ends of the vent system, nor use any screws or rivets to assemble the exhaust system. Lint can become caught in the screen, on the screws or rivets, clogging the duct work and creating a fire hazard as well as increasing drying times. Use an approved vent hood to terminate the duct outdoors, and seal all joints with duct tape. All male duct pipe fittings must be installed downstream with the flow of air. Explosion hazard: Do not install the dryer where gasoline or other flammables are kept or stored. If the dryer is installed in a garage, it must be minimum of 18 inches (45.7 cm) above the floor. Failure to do so can result in death, explosion, fire or burns. English Materials Use only 4 inch (10.2cm) diameter (minimum) rigid of flexible metal duct and approved vent hood which has a swing-out damper hat open when the dryer is in operation. When the dryer stops, the dampers automatically close to prevent drafts and the entrance of insects and rodents. To avoid restricting the outlet, maintain a minimum of 12 inches (30.5cm) clearance between the vent hood and the ground or any other obstruction. The vent flap should be able to move freely. Although vertical orientation of the exhaust system is acceptable. Certain extenuating circumstances could affect the performance of the dryer: 1. Only rigid metal duct work should be used. 2. Venting vertically through a roof may expose the exhaust system to down drafts causing an increase in vent restriction. 3. Running the exhaust system through an area not insulated may cause condensation ...

Эта инструкция также подходит к моделям:
Сушильные машины - RDE200AW (1.1 mb)
Сушильные машины - CRDE200AW (1.1 mb)
Сушильные машины - CRDE400AW (1.1 mb)
Сушильные машины - CRDE200AW (1.1 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории