Войти:
Оценок - 1, средний балл: 3 ( )

Инструкция по эксплуатации LG, модель DLE2532W

Производитель: LG
Размер: 1.65 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


WARNING To reduce the risk of fire, electric shock or personal injury, all wiring and grounding MUST confirm with the latest edition of the National Electrical Code ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer’s responsibility to have the wiring and fuses checked by a qualified electrician to make sure the laundry room has adequate electrical power to operate the dryer. . The dryer is designed to be operated on a separate branch, polarized, three-wire, effectively grounded, 120 Volt, 60 Hertz, AC (alternating current) circuit protected by a 15 Ampere fuse, equivalent fusetron or circuit breaker. . The three-prong grounding plug on the power cord should be plugged directly into a polarized three-slot effectively grounded receptacle rated 120 Volts AC (alternating current) 15 Amps. Refer to Figure 22 to determine correct polarity of the wall receptacle. WARNING This dryer is equipped with a three- prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. NOTE : A qualified electrician should check the polarity of the wall receptacles. If a voltage reading is measured other than that illustrated, the qualified electrician should correct the problem. . DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT WHEN THIS APPLIANCE IS OPERATING. DO NOT OVERLOAD CIRCUITS! . DO NOT operate both a washer and gas dryer on the same circuit. Use separately fused 15 Amp circuits. WARNING To reduce the risk of an electric shock or fire, DO NOT use an extension cord or an adapter to connect the dryer to the electrical power source. DO NOT OVERLOAD CIRCUITS DO NOT USE AN ADAPTER DO NOT USE AN EXTENSION CORD STANDARD 120 VOLT, 60 HERTZ, 3-WIRE EFFECTIVELY GROUNDED CIRCUIT 1 L1 2 Ground 3 Neutral Side 4 Round Grounding Prong 5 Neutral Grounding Instructions . The dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The dryer is equipped with a cord having an equipment-grounding conductor and a three prong grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. WARNING Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly grounded. . Do not modify the plug provided with the dryer unit- if it will not fit the outlet, have a proper outlet installed by a qualified electrician. . If the laundry room’s electrical supply does not meet the above specifications and/or if you are not sure the laundry room has an effective ground, have a qualified electrician or your local electrical utility company check it and correct any problems. Safety Instructions Installation Operating Troubleshooting Customer GAS REQUIREMENTS Safety InstructionsInstallation InstructionsOperating InstructionTroubleshooting TipsCustomer Service Gas Dryers NOTE : The gas service to a gas dryer must conform with the local codes and ordinances or, in the absence of local codes and ordinances, with the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54 or the CAN/CGA-B149, National Gas Installation Code. L.P (Liquefied Petroleum) Gas, 2,500 Btu/ft3 (93.1 MJ/m3), service must be supplied at 10 1.5 in. water column pressure. NOTE : DO NOT connect the dryer to L.P. Gas Service without converting the gas valve. L.P. gas conversion: In U.S.- Conversion must be made by a qualified technician. See gas valve burner base for gas conversion kit part number. In Canada- Conversion must be made by a licensed technician. Contact your local service branch if you require further assistance. The dryer must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test presure equal to or less than 1/2 psi (3.45 kPa). NOTE : When connecting to a gas line, an equipment shutoff valve must be installed within 6 feet (1.8m) of the dryer. An 1/8 in. N.P.T. pipe plug must be installed as shown. Refer to Fig Supply line requirements: Provide a rigid gas supply line to the dryer location. In U.S.-An individual manual shutoff valve must be installed within 1.8m (6 feet) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1*. In Canada-An individual manual shutoff valve must be installed in accordance with the B-149 installation codes, CAN/CGA B-149.1 and B-149.2*. When a rigid pipe is used it should be 1/2 inch IPS. When acceptable to the gas supplier and local codes, 3/8inch approved tubing may be used for lengths under 6.1 m (20 feet). For lengths over 6.1m (20 feet), larger tubing sho...

Эта инструкция также подходит к моделям:
Сушильные машины - DLE2511W (1.65 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории