If good, replace electronic control. E25 Control NTC Open Circuit Control thermistor or its wiring is open. Remove wires from control thermistor. Measure resistance of thermistor. If reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± 10%), check wiring between thermistor and electronic control. If good, replace electronic control. E4A Program Timeout Fault The drying time has exceeded program time for that cycle. Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes. Position cycle selector to NORMAL, temperature selector to HIGH HEAT and touch START. Check for anything that would extend dry times such as: no heat, restricted vent, blower fan blade broken or loose, dryer installed in closet with solid door, or bad connection in moisture sensor bar circuit or dirty bars. If dryer operates normally but code returns, replace electronic control. E5B Heater Fault (no heating) Temperature reading of control thermistor has not changed in a certain amount of time. Position cycle selector to NORMAL, temperature selector to HIGH HEAT and touch START. Measure voltage across terminals on relay RL2 (heater relay) on electronic control. If meter reads 240V on electric models and 120V on gas models, replace electronic control. If meter reads zero, remove power from dryer. Disconnect wire going to NO terminal on the relay RL2. Reconnect power and measure voltage drop between terminal COM on relay RL2 and neutral. If meter reads zero, wire between incoming line and relay RL2 is open. If meter reads 120V, check the rest of the heater circuit. E68 Key (button) Struck Fault One of the keys (buttons) is stuck closed (active). Enter function test mode and perform key (button) test to determine which button is at fault. Carefully free the and perform the test again. If button is free but the key struck code still exists, replace electronic control. E8C Too many trips in a period of time. The safety (high limit) thermostat has tripped too many times within a certain period of program time. Check for blocked lint filter, blocked exhaust, air leaks around air duct, broken blower fan blades, worn or loose drum seals, dryer installed in closet with solid doors or door seal not correctly seated. EAF Watch Dog Reset Microcontroller has been reset by internal Watchdog timer. Clear code, exit mode and start dryer. If problem persists, replace electronic control. NOTE: During normal operation, the display may show: “LOC” - control lock is activated. “PAU” - cycle has been interrupted. 137033000B 0810 FUNCTION TEST SEQUENCE 1. Press and hold Select and Cancel buttons simultaneously for 6 seconds to reset the control. The buzzer will sound. 2. Immediately after, rotate cycle selector knob 5 turns counter-clockwise to the second position from the bottom. Press and hold the Options and Cancel buttons simultaneously for 2 seconds. The control will enter test mode, the buzzer will sound 3 times and all LED’s will rapidly flash. After entering the test mode, the cycle selector knob can now be rotated to select the following tests: Rotate the cycle selector knob clockwise from the starting position: 0 turns: All LED’s will flash. 1 turn: Drive motor runs; heat source is on. Drying LED is lit. “H” and the control thermistor reading will toggle back and forth in the display. 2 turns: Drive motor runs; heat source is off. Cool Down LED is lit and “AF” (Air Fluff) is displayed. 3 turns: Drive motor runs; heat source is off. Drying and Cool Down LED’s are lit and numbers appear in the display showing moisture sensor readings. Opening the door (press in on door switch plunger) and placing a finger on the both moisture sense bars at the same time will make the numbers decrease. In controls that do not have a digit display, the More Dry LED should be ON. Opening the door (press in on door switch plunger) and placing a finger on the both moisture sense bars at the same time will make the Damp LED come on. 4 turns: Drive motor runs; heat source is off. Key test: a. When the Temperature key is pressed, all the temperature LED’s should light. b. When the Dryness key is pressed, all the dryness level LED’s should light. c. When the Options or Select key is pressed, all the Option LED’s should light. d. When the Start/Pause key is pressed, all the cycle status LED’s should light. e. When the Cancel key is pressed, all the cycle status LED’s should light. 5 turns: Drive motor runs; heat source is off. Cool Down LED is lit. Control thermistor reading is displayed. 6 turns: Drive motor runs; heat source is on. Drying LED is lit. Control thermistor reading is displayed. 7-11 turns: All LED’s will flash To EXIT test mode, press and hold the Select and Cancel buttons simultaneously for 6 seconds or disconnect power from dryer. Dryer will be reset for regular operation. Feuille de donnees techniques de secheuse Ces renseignements ne s’adressent qu’a des techniciens qualifies. ATTENTION : DEBRANCHEZ L’ALIMENTATION ELECTRIQUE ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории