Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Maytag, модель Bravos W10163136A

Производитель: Maytag
Размер: 1.26 mb
Название файла: 333ffe0b-688e-412f-88fa-0cd91ff464fc.pdf
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


See “ Electrical Requirements.” ¦ A sturdy floor to support the total weight (dryer and load) of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered. ¦ Cold water faucets located within 4 ft (1.2 m) of the water fill valves, and water pressure of 20-100 psi (138-690 kPa). You may use the water supply for your washer using the “Y” connector and short hose (if needed) which are provided. ¦ 20-100 psi (138-690 kPa) for best performance. ¦ A level floor with a maximum slope of 1" ( 2.5 cm) under entire dryer. Do not operate your dryer at temperatures below 45 .F ( 7. C) . At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended. The dryer must not be installed or stored in an area where it will be exposed to water and/ or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector. Installation Clearances The location must be large enough to allow the dryer door to open fully. 4 Dryer Dimensions 43 ." (110.5 cm) *29 ." (74.3 cm) 29" (73.7 cm) 22." (56.5 cm) * Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements. ” Installation spacing for recessed area or closet installation The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" ( 0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons: ¦ Additional spacing should be considered for ease of installation and servicing. ¦ Additional clearances might be required for wall, door and floor moldings. ¦ Additional spacing should be considered on all sides of the dryer to reduce noise transfer. ¦ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. ¦ Companion appliance spacing should also be considered. ¦ Additional spacing is required if you exhaust out the rear of the dryer to either the right or left side. 3"* (7.6 cm)(7.6 cm) (45.7 cm) 29" (73.7 cm) 14" max.*(35.6cm) 48 in. 2 * (310 cm2) 18"* 24 in. 2 * 3"* (155 cm2) 1" 1" 1" * 29." 5" (2.5 cm) (2.5 cm) (2.5 cm) (74.3 cm) (12.7 cm) A BC A. Recessed area B. Side view - closet or confined area C. Closet door with vents * Required spacing Mobile home - Additional installation requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH. Mobile home installations require: ¦ Metal exhaust system hardware, which is available for purchase from your dealer. ¦ Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening ( such as a nearby window) should be at least twice as large as the dryer exhaust opening. Electrical Requirements - U. S.A. Only It is your responsibility ¦ To contact a qualified electrical installer. ¦ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances. The National Electric Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations. A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269. ¦ To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit. ¦ Do not use an extension cord. ¦ If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. Electrical Connection To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. ¦ This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground conductor is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground conductor must be removed from the external ground connector (green screw) , and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground conduc...

Эта инструкция также подходит к моделям:
Сушильные машины - Bravos W10160250A (1.26 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории