Exceeding the length of duct pipe or number of elbows allowed in the "Maximum Length" charts can cause an accumulation of lint in the exhaust system. Plugging the system could create a fire hazard, as well as increase drying times. 5. Do not screen the exhaust ends of the vent system, nor use any screws or rivets to assemble the exhaust system. Lint can become caught in the screen, on the screws or rivets, clogging the duct work and creating a fire hazard as well as increasing drying times. Use an approved vent hood to terminate the duct outdoors, and seal all joints with duct tape. All male duct pipe fittings must be installed downstream with the flow of air. Explosion hazard: Do not install the dryer where gasoline or other flammables are kept or stored. If the dryer is installed in a garage, it must be minimum of 18 inches (45.7 cm) above the floor. Failure to do so can result in death, explosion, fire or burns. Materials Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible metal duct and approved vent hood which has a swing-out damper cover open when the dryer is in operation. When the dryer stops, the dampers automatically close to prevent drafts and the entrance of insects and rodents. To avoid restricting the outlet, maintain a minimum of 12 inches (30.5 cm) clearance between the vent hood and the ground or any other obstruction. The vent flap should be able to move freely. MAXIMUM EXHAUST LENGTH INSTALL MALE FITTINGS IN THE CORRECT DIRECTION After installation is completed, the following method must be used to determine if the exhaust system is acceptable: 1. Connect an inclined or digital manometer between the dryer and the point the exhaust system connects to the dryer. 2. Set the dryer cycle and temperature to cool down, and start the dryer. 3. Read the measurement on the manometer. 4. The system back pressure must not be higher than 0.75 inches of water column. If the system back pressure is less than 0.75 inches of water column, the system is acceptable. If the manometer reading is higher than 0.75 inches of water column, the system is too restrictive and the installation is unacceptable. Although vertical orientation of the exhaust system is acceptable, certain extenuating circumstances could affect the performance of the dryer: 1. Only the rigid metal duct work should be used. 2. Venting vertically through a roof may expose the exhaust system to down drafts causing an increase in vent restriction. 3. Running the exhaust system through an area not insulated may cause condensation and faster accumulation of lint. 4. Compression or crimping of the exhaust system will cause an increase in vent restriction. The exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage. The more the dryer is used, the more often you should check the exhaust system and vent hood for proper operation. Location of Your Dryer Do Not Install Your Dryer: In an area exposed to dripping water or outside weather conditions. In an area where it will come in contact with curtains, thick carpet, or anything that will obstruct the flow of combustion and ventilation air. On carpet. Floor must be solid with a maximum slope of 1inch (2.54 cm). Installation in Recess or Closet: A dryer installed in a bedroom, bathroom, recess or closet, must be exhausted outdoors. Your dryer needs the space around it for proper ventilation. A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, is required. Air openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable. DIMENSIONS Installation in Mobile Home Dryer must be exhausted outside (outdoors, not beneath the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred. If dryer is exhausted through the floor and area beneath the mobile home is enclosed, the exhaust system must terminate outside the enclosure with the termination securely fastened to the mobile home structure. Refer to previous pages for other important venting requirements. Installation must c...

Эта инструкция также подходит к моделям:
Сушильные машины - GDZ22-2 (359.64 kb)
Сушильные машины - GDZ22-2 (359.64 kb)
Сушильные машины - GDZ22-2 (359.64 kb)
Сушильные машины - GDZ22-2 (359.64 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории