Войти:
Оценок - 6, средний балл: 4 ( )

Инструкция по эксплуатации Alliance Laundry Systems, модель CGDE450AW

Производитель: Alliance Laundry Systems
Размер: 1.57 mb
Название файла: gd450aw_manual.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


In the United States, that only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the manufacturer and that comply with the UL Outline for Clothes Dryer Transition Duct, Subject 2158A (2006), shall be used. 6. In Canada, that the exhaust duct shall be 102mm in diameter. In the United States, the required exhaust duct diameter. 7. The total length of flexible metal duct shall not exceed 2.4m. The exhaust system should be inspected and cleaned a minimum of every 12 months with normal usage. The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation. English RECOMMENDED MAXIMUM Exhaust Hood Types Recommended Use only for short run installations No. of 90. elbows Rigid Metal Rigid Metal 0 90 ft. 60 ft. 1 60 ft. 45 ft. 2 45 ft. 35 ft. 3 35 ft. 25 ft. Note: Exhausting refers to removal of moist air from the drying compartment. 8 English GAS SUPPLY REQUIREMENTS WARNING: Replace copper connecting pipe that is not plastic- coated. Stainless steel or plastic-coated brass MUST be used. 1. Installation MUST conform with local codes. In the absence of local codes, installation must conform with the National Fuel Gas Code, ANSI Z223.1 (latest edition) or in Canada, the current CAN/CGA B149.1 2. The gas supply line should be 1/2 inch (1.27cm) pipe. 3. If codes allow, flexible metal tubing may be used to connect your dryer to the gas supply line. The tubing MUST be constructed of stainless steel or plastic- coated brass. 4. The gas supply line MUST have an individual manual shutoff valve installed within 6 feet (183cm) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. In Canada, an individual manual shut-off valve MUST be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. 5. A 1/8 inch (0.32cm) N.P.T. plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer. 6. The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45kPa). 7. The dryer MUST be isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa). LOCATION OF YOUR DRYER Do Not Install Your Dryer: 1. In an area exposed to dripping water or outside weather conditions. 2. In an area where it will come in contact with curtains, thick carpet, or anything that will obstruct the flow of combustion and ventilation air. 3. On carpet, floor must be solid with a maximum slope of 1inch (2.54 cm). Any floor unevenness should be corrected with leveling legs located on the bottom of the dryer. Installation in Alcove or Closet: 1. DO NOT install your dryer in a closet with a solid door. 2. A dryer installed in a bedroom, bathroom, alcove or closet MUST be exhausted outdoors...

Эта инструкция также подходит к моделям:
Сушильные машины - GDE/GDG450AW (1.57 mb)
Сушильные машины - CGDE450AW (1.57 mb)
Сушильные машины - CGDE450AW (1.57 mb)
Сушильные машины - CGDE450AW (1.57 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории