Инструкция по эксплуатации Porter-Cable, модель NS100A

Производитель: Porter-Cable
Размер: 924.67 kb
Название файла: 8a38bbd6-ae65-2b84-0de4-6ab7eb857c39.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


2. Pull fastener follower (A) Fig. 14, back until hole (B) Fig. 14, catches on latch (C) Fig. 14 and release fastener follower (see Fig. 15). 3. Insert a strip of approved fasteners, see Fig. 16. 4. While holding fastener follower (A) Fig. 14, press latch (C) Fig. 14, and allow fastener follower to slide forward against fasteners (see Fig. 17). 5. Adjust directional exhaust deflector (A) Fig. 18, so that the exhaust air blast will be directed away from the operator. The exhaust deflector provides 8 detented positions for directing the exhaust blast away from the operator. Grasp the deflector and rotate it to the desired position for the current application. Fig. 18 A 6 USING THE TOOL Complete all steps of PREPARING THE TOOL before using the tool. To fire, grip tool firmly, position nose of tool onto work surface, push forward on tool to depress safety, and squeeze trigger to fire a fastener. This “trigger fire” method provides the most accurate fastener placement. This tool is shipped from the factory with a “restrictive fire trigger” that only allows the tool to be fired this way and is less likely to fire an unwanted fastener. An alternate “bottom fire trigger” is available. The “bottom fire” trigger allows the tool to be fired in two different ways. 1. The tool can be fired using the “trigger fire” method described above. OR 2. Grip tool firmly, depress and hold trigger while pushing the tool firmly against work surface. The tool will fire a fastener each time the safety is depressed. This method is known as “bottom fire” and allows very fast repetitive fastener placement. The “bottom fire trigger” is available free-of-charge by calling 1-800-321-9443 in the United States and Canada or 001-901-660-9374 outside the United States and Canada, and providing tool model and serial number. For identification purposes: the Bottom Fire Trigger is black and the Restrictive Fire Trigger is red. CAUTION: Remove finger from trigger when not driving fasteners. Never carry tool with finger on trigger: tool may fire a fastener if safety is bumped. Keep tool pointed in a safe direction at all times. Never attempt to drive a fastener into material that is too hard, or at too step an angle, or near the edge of the workpiece.The fastener can ricochet causing personal injury. Disconnect tool from air supply before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, or handing the tool to another person. Clean and inspect tool daily. Carefully check for proper operation of trigger and safety mechanism. Do Not use the tool unless both the trigger and the safety mechanism are functional, or if the tool is leaking air or needs any other repair. The depth to which a fastener is driven is controlled by the depth adjustment knob (A) Fig. 19. The depth of drive is factory adjusted to a nomimal setting. Test fire a fastener and check depth. If a change is desired, rotate the adjustment knob (A) Fig. 19: the adjustment knob has detents every 1/4 turn. Rotate the knob clockwise (see Fig. 19), to increase the depth of drive, rotate the knob Fig. 19 A counterclockwise to decrease the depth of drive. Test fire another fastener and check depth. Repeat as necessary to achieve desired results. The amount of air pressure required will vary depending on the size of the fastener and the material being fastened. Experiment with the air pressure setting to determine the lowest setting that will consistently perform the job at hand. Air pressure in excess of that required can cause premature wear and/or damage to the tool. 7 Fig. 20 Fig. 21 Fig. 20 Fig. 21 CLEARING A JAMMED FASTENER 1. CAUTION: Disconnect tool from air supply. 2. Open magazine and remove any remaining fasteners. CAUTION: Remove fasteners from tool before opening the fastener guide plate. Fasteners are under pressure and may shoot out of magazine which could cause injury. 3. Depress the quick release latch and open the fastener guide plate (see Fig. 20). 4. Remove the jammed fastener (see Fig. 21). 5. Depress the quick release latch, close the fastener guide plate, and release the latch. NOSE CUSHION This tool is equipped with a rubber nose cushion (A) Fig. 22, that prevents marring of finished surfaces by the metal safety during normal operation. The nose cushion can be removed and stored in the rear area of the tool (B) Fig. 22, when it is not required. CAUTION: Disconnect tool from air supply before removing or reinstalling rubber nose cushion. MAINTENANCE Fig. 22 A B CLEAN AND INSPECT DAILY CAUTION: Disconnect tool from air supply before cleaning and inspection.Correct all problems before placing the tool back in use. Wipe tool clean and inspect for wear or damage. Use non-flammable cleaning solutions to wipe exterior of tool only if necessary. DO NOT SOAK tool with cleaning solutions. Such solutions can damage internal parts. Inspect trigger and safety mechanism to assure system is complete and functional: no loose or missing...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории