Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Campbell Hausfeld, модель FP2048

Производитель: Campbell Hausfeld
Размер: 2.26 mb
Название файла: 0f35706f-3267-466b-9dab-e0b5064cf272.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


Liste de Repuestos FP204800, FP204900 No. de Numero No. de Numero Ref. Descripcion de pieza Ctd. Ref. Descripcion de pieza Ctd. Compr esor es Sin Aceit e Guia de diagnostico de averias (Continuacion) Problema Posible(s) Causa(s) Accion a tomar Exceso de humedad en 1. Demasiada agua en el tanque el aire de descarga 2. Humedad elevada 1. Drene el tanque, incline el tanque para eliminar la humedad 2. Llevelo a un area menos humeda, utilice un filtro de aire de linea Nota: La condensacion de agua no es una causa para el malfuncionamiento del compresor. El compresor funciona 1. Presostato defectuoso 1. Cambie el interruptor de presion en forma continua y la 2. Valvula de seguridad defectuosa 2. Cambie la valvula de retencion con un repuesto valvula de seguridad se original abre cuando aumenta la presion Arranques y paradas 1. Demasiada condensacion en el excesivas tanque 2. Conexiones flojas (accesorios, tuberia, etc.) 22 Sp 1. Drene con mas frecuencia 2. Revise todas las conexiones con una solucion de agua y jabon. Si se detecta una fuga, apriete. O quite la conexion y aplique cinta para tuberias a las rocas y vuelva a armar. FP2048, FP2049 Installation (Continued) ! DANGER Do not use a grounding adapter with this product! 2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire. Never connect ! WARNING green (or green and yellow) wire to a live terminal. 3. Check with a qualified electrician or serviceman if grounding instructions are not completely understood, or if in doubt as to whether product is properly grounded. Do not modify plug provided; if it will not fit outlet, have proper outlet installed by a qualified electrician. Overheating, short ! CAUTION circuiting and fire damage will result from inadequate wiring, etc. Operation Definition of Terms Regulator - The regulator controls the amount of air pressure released at the hose outlet. ASME Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum. Handle - Designed to move the compressor. Drain Valve - This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of corrosion. Reduce tank pressure below 10 psi, then drain moisture from tank daily to avoid tank corrosion. Drain moisture from tank by opening the drain valve located underneath the tank. ON/OFF Switch Drain Valve Figure 2 - Unit Identification LUBRICATION This is an oilless product and DOES NOT require lubrication to operate. BEFORE FIRST START-UP BREAK-IN PROCEDURE (Complete this procedure before using compressor for the first time. Once completed, it is not necessary to repeat.) 1. Turn regulator knob fully clockwise (to the right) to open air flow. 2. Turn on/off switch to OFF position. 3. Plug in power cord. 4. Turn on/off switch to ON position and run compressor for 5 minutes. 5. Turn on/off switch to OFF position. 6. Unplug power cord. The compressor is now ready for use. BEFORE EACH START-UP Handle Regulator Safety Valve OPERATING PROCEDURE 1. Turn regulator knob fully counterclockwise (to the left) to close air flow. 2. Connect air hose to outlet of regulator. 3. Turn on/off switch to OFF position. 4. Plug in power cord. 5. Turn on/off switch to ON position and let compressor run until it reaches automatic shutoff pressure. 6. Attach tire chuck or tool to end of hose. 7. Turn regulator knob clockwise (to the right) to desired pressure of tool being used. On/Off cycling of compressor In the ON position, the compressor pumps air into the tank. When a shutoff (preset “cut-out”) pressure is reached, the compressor automatically shuts off. Extension cords for 120V/2.5 Amp Unit Length of Cord (ft) 25 50 100 150 200 250 300 400 500 Gauge of Cord 18 18 16 14 14 12 12 10 10 3 Oilless Compressors Operation (Continued) If the compressor is left in the ON position and air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically at its preset “cut-in” pressure. When a tool is being used continuously, the compressor will cycle on and off automatically. In the OFF position, the pressure switch cannot function and the compressor will not operate. Make sure switch is in OFF position when connecting or disconnecting power cord from electrical outlet. ASME SAFETY VALVE Do not remove or ! WARNING attempt to adjust the safety valve! Figure 3 Check the safety valve by performing the following steps: 1. Plug the compressor in and run until shut off pressure is reached (see Operating Procedure). 2. Wearing safety glasses, pull the ring on the safety valve to release pressure from compressor tank. Use your other hand to deflect fast-moving air from being directed toward your face. 3. The safety valve should automatically close at approximately 40-50 PSI. If the sa...

Эта инструкция также подходит к моделям:
Строительные пистолеты - FP2049 (2.26 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории