Войти:
Оценок - 4, средний балл: 3.3 ( )

Инструкция по эксплуатации Porter-Cable, модель N030769

Производитель: Porter-Cable
Размер: 3.65 mb
Название файла:
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


When the switch is in the unlocked position, the tool will be fully operational. The trigger should always be locked off whenever any adjustments are made or when tool is not in use. LOADING THE TOOL (FIG. 3) Keep the tool pointed away from yourself and others. Serious personal injury may result. Never load fasteners with the contact trip or trigger activated. Personal injury may result. Disconnect tool from air supply before removing or re-installing no-mar pad. 1. Read all Safety Warnings before using tool. 2. Connect the tool to air supply. 3. Lock off trigger. 4. Push magazine release (F) and pull magazine (E) back. 5. Insert fasteners into the side of the magazine. Be sure the fasteners ride on their tips in the nail channel. 6. Push magazine closed until it locks in place. ACTUATING TOOL To reduce the risk of injury, ALWAYS wear proper eye [ANSI Z87.1 (CAN/CSA Z94.3)] and hearing protection [ANSI S12.6 (S3.19)] when operating this tool. A nail will fire each time the trigger is depressed as long as the contact trip remains depressed which could result in inadvertant actuation. The sequential action trigger’s intended use is for intermittent nailing where very careful and accurate placement is desired. 1. Depress the contact trip firmly against the work surface. 2. Depress the trigger. ADJUSTING DEpTH (FIG. 4) To reduce risk of serious injury from accidental actuation when attempting to adjust depth, ALWAYS: • Lock OFF trigger. • Disconnect air supply. • Avoid contact with trigger during adjustments. The depth that the fastener is driven can be adjusted using the depth adjustment next to the trigger of the tool. 1. To drive the fastener shallower, rotate the depth setting wheel (L) to the right. 2. To drive a fastener deeper, rotate the depth setting wheel (L) to the left. CLEARING A JAMMED NAIL (FIG. 5) Lock off trigger, disconnect air line from tool and remove fasteners from magazine before making adjustments or personal injury may result. If a nail becomes jammed in the nosepiece, keep the tool pointed away from you and follow these instructions to clear: 1. Lock off trigger. 2. Disconnect air supply from tool and lock trigger. 3. Release magazine release from behind nails. 4. Push down jam clearing latch (A) then pull up to open front door (P). 5. Remove bent nail, using pliers if necessary. 6. If driver blade is in the down position, insert screwdriver or other rod into nosepiece and push driver blade back in position. 7. Remove rod and close front door. 8. Lift latch to secure door to nosepiece. 9. Reattach air supply. 10. Reinsert nails into magazine (see Loading the Tool). 11. Release magazine release. NOTE: Should nails continue to jam frequently in nosepiece, have tool serviced by an authorized PORTER-CABLE service center. COLD WEATHER OpERATION When operating tools at temperatures below freezing: 1. Make sure compressor tanks have been properly drained prior to use. 2. Keep tool as warm as possible prior to use. 3. Make certain all fasteners have been removed from magazine. 4. Lower air pressure to 80 psi or less. 5. Reconnect air and and load nails into magazine. 6. Actuate the tool 5 or 6 times into scrap lumber to lubricate o-rings. 7. Turn pressure up to operating level (not to exceed 120 psi) and use tool as normal. 8. Always drain the compressor tanks at least once a daily. HOT WEATHER OpERATION Tool should operate normally. However, keep tool out of direct sunlight as excessive heat can deteriorate bumpers, o-rings and other rubber parts resulting in increased maintenance. BELT HOOK (FIG. 1) The PORTER-CABLE nailers include an integrated belt hook (I) and can be rotated to either side of the tool to accommodate left- or right - handed users. It can also be rotated out of the way when not in use. If the hook is not desired at all, it can be removed from the tool. To remove belt hook: 1. Lock off trigger. 2. Disconnect the tool from air supply. 3. Using the appropriate hex wrench, remove the end cap screws from the end cap of the tool. 4. Remove the belt hook. 5. Replace end cap and gasket. Ensure that the three screws are tight. 6. Replace and tighten air fitting. MAINTENANCELockofftrigger,disconnectairlinefromtoolandremovefastenersfrommagazinebeforemakingadjustmentsorpersonalinjurymayresult. DAILY MAINTENANCE CHARTCLEANINGNever use solvents or other harsh chemicals for cleaning the non-metallic parts of the tool. These chemicals may weaken the materials used in these parts. Use a cloth dampened only with water and mild soap. Never let any liquid get inside the tool; never immerse any part of the tool into a liquid. REpAIRSFor assistance with your tool, visit our website at for a list of service centers, or call the PORTER-CABLE Customer Care Center at (888) 848-5175. SERvICEREpLACEMENTpARTSUse only identical replacement parts. For a parts list or to order parts, visit our website at servicenet. porter-cable.com. You can also order parts from your nearest PORTE...

Эта инструкция также подходит к моделям:
Строительные пистолеты - BN200B (3.65 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории