|
Фрагмент инструкции
11. Connect tool to air supply hose with a coupling that automatically removes all pressure from the tool when the coupling is disconnected. Fig. 7. 12. Disconnect tool from air supply hose before doing tool maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, or handing the tool to another person. Fig. 7. 13. Never use a tool that is leaking air, has missing or damaged parts, or requires repair. Make sure all screws and caps are securely tightened. Fig. 8. 14. Never use tool if safety, trigger or springs are inoperable, missing or damaged. Do not alter or remove safety, trigger, or springs. Make daily inspections for free movement of trigger and safety mechanism. Fig. 8. 15. Do not use tool without safety warning label. If label is missing, damaged or unreadable, contact the Customer Care Department at 1-800-888-2468 for a replacement. Fig. 9. 16. Only use parts and accessories approved by DeVilbiss Air Power Company. 17. Connect tool to air supply before loading fasteners, to prevent a fastener from being fired during connection. The tool driving mechanism may cycle when tool is connected to the air supply. Fig. 10. 18. Always assume the tool contains fasteners. No horseplay. Respect the tool as a working implement. Fig. 11. 19. Operator and bystanders should wear hard hats to safeguard against possible injuries. Fig. 12. 20. Keep bystanders and children away from work area when operating this power tool. Fig. 8 Fig. 9 Fig. 11 Fig. 12 Fig. 7 Fig. 10 5 21. Do not load fasteners with trigger or safety depressed, to prevent unintentional firing of a fastener. Fig. 13 22. Remove finger from trigger when not driving fasteners. Never carry tool with finger on trigger. Contact Actuation tools will fire a fastener if the safety mechanism is bumped while trigger is depressed. Fig. 14. 23. Do not overreach. Keep proper footing and balance at all times when using or handling the tool. 24. Fire fasteners into work surface only: never into materials too hard to penetrate. Fig. 15. 25. Grip tool firmly to maintain control while allowing tool to recoil away from work surface as fastener is driven. With Contact Actuation tools an unwanted fastener will be fired if the safety mechanism is allowed to recontact work surface before trigger is released. 26. Do not drive fasteners on top of other fasteners, or with the tool at too steep an angle: the fasteners can ricochet causing personal injury. Fig. 15. 27. Do not drive fasteners close to the edge of the workpiece. The workpiece is likely to split allowing the fastener to fly free or ricochet causing personal injury. Fig. 16. 28. FOR TOOLS USED IN CONTACT ACTUATION MODE, Do not use on scaffoldings or ladders or for tasks in which changing location involves the use of scaffoldings, stairs, ladders, and the like. Do not use for specific tasks such as closing boxes or crates or fitting transportation safety systems on vehicles and wagons. Fig. 17. Fig. 13 Fig. 14 Fig. 15 Fig. 16 Fig. 17 6 EMPLOYER’S RESPONSIBILITIES Employer must enforce compliance with the safety warnings and all other instructions contained in this manual. Keep this manual available for use by all people assigned to use this tool. For personal safety and proper operation of this tool, read and understand tool labels and manual. Failure to follow warnings could result in DEATH or SERIOUS INJURY. Read and follow all of these instructions carefully. FUNCTIONAL DESCRIPTION Ex-Cell Model ENS100 is designed to install generic 18 ga. narrow (1/4") crown staples of various lengths from 1/2" to 1" long. Narrow crown staples are loaded into the magazine from the bottom. Ex-Cell Model ENS150 is designed to install generic 18 ga. narrow (1/4") crown staples of various lengths from 1/2" to 11/2" long. Narrow crown staples are loaded into the magazine from the bottom. Ex-Cell stapling tools are compact, lightweight, high performance tools designed for molding, interior trim, paneling, cabinetry, picture/mirror frames and crafts. Features include jam release mechanism, tool free adjustable exhaust, fastener reload indicator, safety positioned on rear of nose and a removable rubber nose cushion. CARTON CONTENTS 1) Stapler 3) Air Tool Oil Bottle 2) Staples 4) Owner's Manual POWER SOURCE This tool is designed to operate on clean, dry, compressed air at regulated pressures between 70 and 110 PSI (Pounds per Square Inch)(4.8 to 7.6 BAR). The preferred system would include a filter, a pressure regulator, and an automatic oiler located as close to the tool as possible, within 15 ft/4.6 m is ideal. The tool is equipped with a 1/4" male “quick connector”. All compressed air contains moisture and other contaminates that are detrimental to internal components of the tool. An air line filter will remove most of these contaminates and significantly prolong the life of the tool. If an in-line oiler is not available: place five or six drops of Air Tool Oil into the tool’s air inlet at the beginning...
Эта инструкция также подходит к моделям:Строительные пистолеты - Ex-Cell ENS100 (467.35 kb)
Строительные пистолеты - Ex-Cell ENS150 (467.35 kb)