Войти:
Оценок - 5, средний балл: 3.8 ( )

Инструкция по эксплуатации Alliance Laundry Systems, модель BF50PV

Производитель: Alliance Laundry Systems
Размер: 1.17 mb
Название файла:
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


CAUTION Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked. SW020 The washer-extractor must be placed on a smooth level surface so that the entire base of the machine is supported and rests on the mounting surface. (Do not support the washer- extractor on only four points.) The 35-pound, 50-pound, and 85-pound capacity washer-extractors do not require anchoring unless mandated by state or local codes. Static and dynamic loads on the floor or foundation are shown in the table below. This table can be used as a reference when designing floors and foundations. Floor Load Data 35 50 85 Static floor load, lbs (kN) 1453 (6.47) 1929 (8.58) 3452 (15.4) Static pressure, lbs-ft2 (kN-m2) 153 (7.32) 172 (8.23) 214 (10.3) Dynamic floor load, lbs (kN) 150 (0.67) 200 (0.89) 400 (1.78) Maximum dynamic load, lbs (kN) 150 (0.67) 200 (0.89) 400 (1.78) Dynamic pressure, lbs-ft2 (kNm2) 15.8 (0.76) 17.9 (0.86) 24.8 (1.19) F232058 Installation Mechanical Installation Mounting Bolt Installation for 35-Pound, 50-Pound, and 85-Pound Capacity Models See Figure 5 for the mounting bolt layout for 35-pound capacity models. See Figure 6 for the mounting bolt layout for 50-pound capacity models. See Figure 7 for the mounting bolt layout for 85-pound capacity models. (The front of the washer-extractor is the bottom of the diagram.) See Figure 8 for detailed information regarding the machine anchor bolt that should be used. Figure 6 U093IB 4" (102 mm) 4" (102 mm) 31" (787 mm) 41 3/10" (1049 mm) 44 2/5" (1127 mm) 31 3/4" (806 mm) 4 1/2" (116 mm) 39" (991 mm) 50 Figure 5 U092IB 27" (686 mm) 29 1/2" (749 mm) 39 1/10" (992 mm) 35" (889 mm) 40" (1016 mm) 4" (102 mm) 4" (102 mm) 4 1/2" (116 mm) 35 Figure 7 U094IB 46 1/2" (1181 mm) 55 9/10" (1419 mm) 50" (1270 mm) 4" (102 mm) 4" (102 mm) 4 1/2" (116 mm) 40 1/2" (1027 mm) 38 1/2" (978 mm) 85 F232058 Installation Mechanical Installation (Continued) 5. Fill the spaces between the washer- extractor base and floor with a good quality non-shrinking machinery grout to Figure 8 After the anchor bolts are installed and the concrete has cured, proceed as follows: ensure a stable installation. See Figure 9 for grouting the 35-pound capacity model. See Figure 10 for grouting the 50-pound capacity model. See Figure 11 for grouting the 85-pound capacity model. Figure 9 2" (51 mm) 6" (152 mm) MIN Locknut Base Frame Grout Anchor Bolt 3 1/2 x 2 Inch Dia. Bolt U095IEP U096I 1. Place the washer-extractor adjacent to the foundation. Do not attempt to move it by pushing on the sides. Always insert a pry bar or other device under the bottom of the frame of the washer-extractor to move it. 2. Remove the wood skid by unscrewing the carriage bolts holding it to the bottom frame of the washer-extractor. 3. Place the washer-extractor carefully over the anchor bolts. Never attempt to lift the machine by the door handle or by pushing on the cover panels. 4. Raise and level the washer-extractor 1/2 inch off the floor on three points, using spacers such as nut fasteners. U097I Figure 10 F232058 Installation U098I Figure 11 6. Remove the spacers carefully, allowing the machine to settle into the wet grout. 7. Position the mounting bolt washers and locknuts on the anchor bolts and fingertighten locknuts to machine base. 8. After the grout is completely dry, tighten the locknuts by even increments – one after the other – until all are tightened evenly and the machine is fastened securely to the floor. 9. Remove the four red transport brackets used to secure the machine during shipping. See Figure 12. F232058 Installation B147IE3A Rear Panel Four (4) Transport Brackets Front Panel Figure 12 F232058 Drain Connection A drain system of adequate capacity is essential to washer-extractor performance. Ideally, the water should empty through a vented pipe directly into a sump or floor drain. Figures 13 and 14 show drain line and drain trough configurations. Installation Before any deviation from specified installation procedures is attempted, the customer or installer should contact the distributor. Increasing the drain hose length, installing elbows, or causing bends will decrease drain flow rate and increase drain times, impairing washer-extractor performance. Waste Line Rear of Machine Vent Drain Pipe Tee Waste Line P024I1A Rear of Machine Drain Pipe Steel Grate Drain Trough Strainer Line Waste P025I1A Figure 13 A flexible connection must be made to a vented drain system to prevent an air lock and to prevent siphoning. If proper drain size is not available or practical, a surge tank is required. A surge tank in conjunction with a sump pump should be used when gravity drainage is not possible, such as in below-ground-level installations. Figure 14 See the Cabinet Freestanding Drain Information table in this subsection for capacity-specific drain information. Installatio...

Эта инструкция также подходит к моделям:
Стиральные машины - BF35PV (1.17 mb)
Стиральные машины - BF85PV (1.17 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории