Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации GE, модель DMCD330EHWC

Производитель: GE
Размер: 1.06 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


dampened wall cap in regard to resistance to air flow, prevention of back drafts, and maintenance required to prevent clogging. SEPARATION OF TURNS For best performance, separate all turns by at least 4 ft. of straight duct, including distance between last turn and exhaust hood. TURNS OTHER THAN 90° • One turn of 45° or less may be ignored. • Two 45° turns should be treated as one 90° turn. • Each turn over 45° should be treated as one 90° turn. SEALING OF JOINTS • All joints should be tight to avoid leaks. The male end of each section of duct must point away from the dryer. • Do not assemble the ductwork with fasteners that extend into the duct. They will serve as a collection point for lint. • Duct joints can be made air and moisture-tight by wrapping the overlapped joints with duct tape. • Horizontal runs should slope down toward the outdoors 1/2 inch per foot INSULATION Duct work that runs through an unheated area or is near air conditioning should be insulated to reduce condensation and lint build-up. Installation Instructions [4] EXHAUST CONNECTION A} WARNING - TO REDUCE THE RISK OF FIRE OR PERSONAL INJURY: • This dryer must be exhausted outdoors. • Use only metal duct. • Do not terminate exhaust in a chimney, any gas vent, under an enclosed floor (crawl space), or into an attic. The accumulated lint could create a fire hazard. • Provide an access for inspection and cleaning of the exhaust system, especially at turns. Inspect and clean at least once a year. • Never terminate the exhaust into a common duct with a kitchen exhaust. A combination of lint and grease could create a fire hazard. • Do not obstruct incoming or exhausted air. THIS DRYER COMES READY FOR REAR EXHAUSTING. IF SPACE IS LIMITED, USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET. STANDARD REAR EXHAUST (Vented above floor level) NOTE: ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING. 4 GS LEVELING AND STABILIZING YOUR DRYER STAND THE DRYER UPRIGHT NEAR THE FINAL LOCATION AND ADJUST THE 4 LEVELING LEGS, AT THE CORNERS, TO ENSURE THAT THE DRYER IS LEVEL FROM SIDE TO SIDE AND FRONT TO REAR. LEVEL LEGS CUT THE METAL EXHAUST DUCT (NOT SUPPLIED) TO THE PROPER LENGTH. NOTE: WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING. HOWEVER, IF FLEXIBLE DUCTING IS USED IT MUST BE METAL NOT PLASTIC. STANDARD REAR EXHAUST (Vented at floor level) FOR STRAIGHT LINE INSTALLATION, CONNECTTHE DRYER EXHAUST TO THE EXTERNAL EXHAUST HOOD USING DUCT TAPE OR CLAMP. (CORD NOT SUPPLIED WITH DRYER) Installation Instructions, Indoor Exhausting USING FLEXIBLE METAL DUCTS If rigid all-metal duct cannot be used, then flexible all-metal ducting can be used, but it will reduce the maximum recommended duct length. In special installations when it is impossible to use only metal ducting, then UL-listed clothes dryer flexible metal transition duct may be used as transition venting between the dryer and wall connection only. The use of this ducting will affect dry time. If flexible transition duct is necessary, the following directions must be followed. • Use the Shortest Length Possible. • Stretch the Duct to Its Maximum Length to avoid kinks. • Do Not Crush or Collapse the Duct. • Never Use Transition Duct Inside the Wall or Inside the Dryer. • Avoid Resting the Duct on Sharp Objects. • Venting Must Conform to Local Building Codes. ELBOW HIGHLY RECOMMENDED. 5 \6\ ALCOVE OR CLOSET INSTALLATION • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be vented to the outdoors. See the EXHAUST INFORMATION sections 3 & 4. • Minimum clearance between dryer cabinet and adjacent walls or other surfaces is: 0 in. either side 3 in. front and rear • Minimum vertical space from floor to overhead cabinets, ceiling, etc. is 52 in. • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. \7] BATHROOM OR BEDROOM INSTALLATION • The dryer MUST be vented to the outdoors. See EXHAUST INFORMATION section 3 & 4. • The installation must conform with local codes or, in the absence of local codes, with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70. ® MOBILE OR MANUFACTURED HOME INSTALLATION • Installation must conform to the MANUFACTURED HOME CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32-80 or, when such standard is not applicable, with AMERICAN NATIONAL STANDARD FOR MOBILE HOME, ANSI/NFPA NO. 501B. • The dryer MUST be vented to the outdoors with the termination securely fastened to the mobile home structure. (See EXHAUST INFORMATION section 3 & 4.) • The vent MUST NOT be terminated beneath a mobile or manufactured home. • The vent duct material MUST BE METAL. • Do not use sheet metal screws or other fastening d...

Эта инструкция также подходит к моделям:
Стиральные машины - 500A187P044 (1.06 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории