Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации KVH Industries, модель TracVision 6

Производитель: KVH Industries
Размер: 1.27 mb
Название файла: 3260508f-b5c4-4093-863c-5fcc5a6d638c.pdf

Язык инструкции:en

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


86 54-0166 Maintenance Port Parser Commands Maintenance Port Parser Commands Set RF Tracking Parameters Function: sets RF tracking parameter Command: @SATCONFIG,X,N,F,S,C,ID,P,B,D Response: Echoes the input data Where: @SATCONFIG = directs data to the RF Board X = satellite location A or B N = satellite table # (98 & 99 are slots for user- configured satellites) F = frequency in MHz (either 00000 or a range from 10700 - 12700) S = satellite transponder symbol rate in Mbit/second (01000 - 29999) C = FEC code (e.g., 12, 23, 34, 56, 67, 78) ID = satellite network ID in hexidecimal format (0x####) P = LNB polarization (V = vertical, H = horizontal, R = right, L = left) B = LNB down conversion frequency (L = low, H = high, G = Latin America, U = USA) D = decoding type (0 = test, 1 = DSS-A, 2 = DSS-B, 3 = DVB) Switch Satellites Function: shifts tracking to the second satellite Command: @L,A or B Response: echoes the command Where: A = switches to Satellite A or B = switches to Satellite B ID Match/Decoded Network ID Function: reports ID match and decoded network ID Command: @CHECKID Response: Y,0X#### N,0X#### Y,NoID N,NoID Where: Y = yes N = no 0X#### = network ID NoID = satellite unidentified 54-0166 87 TracVision 6 Technical Manual TracVision 6 Technical Manual Frequency Scan DoNOTuse the Frequency Scan function unless directed by KVH Technical Support or a KVH- authorized technician.Improper data selection may affect the system’s operation. Function: updates satellite frequency data Command: @SC,XXXXX,YY Where: XXXXX = symbol rate (010000 - 399999) YY = FEC code (e.g., 12, 23, 34, 56, 67, 78) Response: system automatically searches for the frequency with the strongest signal, then updates the satellite’s programmed data with the new frequency (and associated network ID) and stores it in the satellite library RF PCB Software Version Function: reports RF PCB software version Command: @VER Response: RF PCB Version X.X Report Tracking Information Function: reports hardware/software locks, AGC value, bit error rate, and ADC value Command: @I Response: I,X,G,B,D,Y Where: X = hardware lock (0 = not locked, 1 = locked on satellite) G = AGC value (signal level) B = bit error rate D = ADC value Y = software lock (0 = not locked, 1 = locked on satellite) 88 54-0166 Maintenance Port Parser Commands Maintenance Port Parser Commands E.6 Installation Commands Set/Report GPS Position Table E-6 Installation Commands Function: reports or sets default GPS position Command: GPS GPS,XX,D,YYY,E Response: GPS = XXD YYYE GPS: XXD YYYE Where: XX = latitude (0-90) D = S (South) or N (North) YYY = longitude (0-180) E = E (East) or W (West) Report Satellite Names Function: reports names for satellites A and B Command: SATINSTALL Response: SATINSTALL,, Report Tracked Satellite Function: reports name of satellite currently being tracked Command: SAT Response: SAT = Report Configured Satellite Names Function: reports names for all configured satellites Command: SATLISTA Response: SATLISTA,,..., Report Valid Satellite B Selections Function: reports names for all valid Satellite B selections for a given Satellite A selection Command: SATLISTB, Response: SATLISTB,, ..., Install Satellite Pair Function: installs satellites A and B as the satellite pair Command: SATINSTALL,, Response: If valid pair, echoes the input data If invalid pair, returns error message 54-0166 89 Configure Longitude of a User-configurable Satellite Function: configures one of the user-configurable satellites with the longitude provided Command: SATCONFIG,USERX,YYY,Z,D,L Response: If valid, echoes the input data If invalid, returns error message Where: X = 1 or 2 YYY = longitude (0-180) Z = E (East) or W (West) D = decoding type (0 = test, 1 = DSS-A, 2 = DSS-B, 3 = DVB) L = LNB polarization (C = circular, L = linear) Set Saved Satellite Position Function: sets saved satellite position Command: GOTO,AZXXXX,ELYYY Response: SAVED SAT POS: AZ = XXXX, EL = YYY Where: XXXX = azimuth (0000 - 3599) YYY = elevation (100 - 850) E.7 Debug Commands Table E-7 Enter Debug Mode Debug Commands Function: enters Debug mode Command: DEBUGON Response: echoes the command, system enters Debug mode Limit Switch Test Function: performs a limit switch test Command: =LSTEST Response: Limit Switch Status: PASS Set/Report Offset Angles Function: reports or sets system offset angles Command: OFFSETS OFFSETS,XXXXX,YYYY Response: Offsets = XXXXX.X YYYYY.Y Where: X = azimuth offset (-1800 - 1800) Y = elevation offset (-450 - 450) 90 54-0166 Maintenance Port Parser Commands Maintenance Port Parser Commands Apply Default Values to Default Satellites Function: updates the default satellites to the default values Command: SATPAIR,X Response: displays numerous frequency commands and reports “Satellite Installation Complete” Where: X = 0 (satellites default to Astra1 & Hot...

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории