Фрагмент инструкции


Dispense all of the hot water into a large container. Repeat for the remaining dispense valves. 5. Remove the mixing chambers, nozzles, and static mixers. Rinse in hot water to remove excess pulp and concentrate. 6. Place the mixing chambers, nozzles, and static mixers in a separate container of sanitizing solution and agitate vigorously. Allow the parts to soak for two minutes. Rinse thoroughly with fresh tap water. 7. Reinstall the static mixer, nozzles, and mixing chambers. © 2004, IMI Cornelius Inc. - 9 -Publication Number: TP00968 Quest Juice Training Manual Step 2 - Sanitize Pump System 1. Fill a clean concentrate container with 2 quarts (1.9L) of fresh sanitizing solution. 2. Place handles in the “dispense” position and close the door. 3. Press and hold the dispense button for 90 seconds then stop. Allow sanitizing solution to remain in the lines for 5 minutes. 4. After 5 minutes, dispense the remaining sanitizing solution. Step 3 - Prepare Dispenser for Use 1. Replace sanitizing solution container with a concentrate container and close the door. 2. Press and hold the dispense button until juice appears from the nozzle. Next dispense and discard at least two 8 oz. (236.6ML) cups of juice in order to prime the system and prepare it for operation. SEMI-ANNUAL CAUTION: The following procedures require removal of the dispenser side panel(s). Disconnect the power cord from the receptacle prior to proceeding. Clean Water Inlet Strainer: 1. Remove the right side panel from the dispenser. 2. Turn off the water supply to the dispenser. 3. Remove the access port from the “Y” shaped water inlet solenoid located on the right side of the dispenser. 4. Clean and reinstall the stainless steel water strainer. Clean Chassis Interior: 1. Clean the condenser cooling fins. 2. Clean the air inlet grilles located on the rear and top panels of the dispenser. 3. Clean the interior base. 4. Wipe the fan blade clean. 5. Reinstall the right side panel, turn on the water supply, and plug the dispenser into the power receptacle. Check and Top-Off Water Ice Bath: 1. Remove the drip tray and lower splash panel. 2. If the Ice bath level is below the “Full” indicator, top it off with water. Refer to the Filling the Ice Bath procedure in the Installation section of this manual. Publication Number: TP00968 - 10 - © 2004, IMI Cornelius Inc. Quest Juice Training Manual ANNUALLY Replace Pump Tubing: A replacement pump tubing kit, part#45098, is available. The kit consists of one pre-cut length of pump tubing, two white plastic hose clamps, and instructions. Removing Pump Platform(s): 1. Remove the concentrate containers from the dispenser and place them in a refrigerator. 2. Remove the cabinet shelf that the concentrate containers sit on. 3. Flush the system prior to removing the pump platform (refer to the Daily section located at the beginning of the Planned Maintenance Schedule). Remove the dispense nozzles and static mixers. 4. Unplug the water line quick disconnect by pressing the gray button (see Fig. 1&2). 5. Slide the locking latch forward. Lift the platform slightly and pull forward to gain access to the electrical connector (see Fig.1). 6. Unplug the electrical connector by squeezing the locking tabs on either side and pulling out the connector. Lift and remove the pump platform (see Fig.1). Replacing Pump Tubing: 1. Remove pump platform (refer to the Removing Pump Platform(s) procedure located earlier in this section). 2. Remove the two white plastic hose clamps from the pump tube connections (see Fig. 1&2). Remove the concentrate delivery tubes from the hose ends. 3. Loosen and remove the four screws from the pump body (see fig 3). 4. Remove the rear pump body half only to reveal the pump tube and rollers. 5. Remove the old pump tube from the pump body. If the roller assembly comes out with the tubing, place it back into the pump housing being sure to align the roller assembly shaft keyway to the motor shaft so that the two interlock. 6. Firmly press the new hose into the pump body around the roller assembly, being sure to keep the protruding ends even with each other. 7. Once the tubing is in place, hold the tubing with one hand, capture the lower part of the tubing with the outer housing, then proceed to capture the shaft of the roller assembly and push the rear pump housing into place. Make sure to capture the tubing within the body and not pinch it between the halves. Do not use any tool other than your finger tips to manipulate the tubing into the housing or you may damage the tube. Fig.1 Fig. 2 © 2004, IMI Cornelius Inc. - 11 -Publication Number: TP00968 Quest Juice Training Manual 8. While holding the pump halves together with your hand, reinsert the four screws and tighten using a crisscross pattern as shown. The screws should be tightened about 1/4 turn beyond snug. 9. Insert the two concentrate delivery tubes into the pump tubing ends and secure them using the new hose clamps supplied in the kit. Be sure to use plie...

Эта инструкция также подходит к моделям:
Соковыжималки - 4 Flavor (1.85 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории