Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Siemens, модель CIELO

Производитель: Siemens
Размер: 256.33 kb
Название файла: 67e026eb-672b-4b40-8f66-bd5e10a76ed6.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Small recess in the Nib in the audio shoe hearing system housing Expect the CIELO Dir audio shoe 16 Before the audio shoe can be connected to the hearing system the following steps have to be fullfilled: 1. Open the battery compartment 2. Open the audioshoe cover 3. Close the battery compartment Attaching the audio shoe Take the audio shoe and hook the two nibs into the two small recesses of the hearing system housing. Slide the audio shoe to the inner side of the hearing system housing until it snaps into the end position. Removing the audio shoe To remove the audio shoe, slide the audio shoe in the opposite direction. With the connected audio shoe the battery compartment switch is disable and the hearing system only can be switched off with the push button. Safety Instructions for hearing systems with audio input The audio input may be connected to line-operated equipment only if the equipment fulfils the safety requirement IEC 65 / DIN VDE 0860. Using the telephone Automatic telephone program With AutoPhone functionality, your CIELO hearing system will automatically switch to the telephone program when you hold a hearinginstrument- compatible-telephone handset near to your hearing instrument. When you have finished speaking on the phone and you move the telephone handset away from the hearing instrument, it will automatically return to the previously used hearing program. You can also select the telephone program manually by using the program push button. The telephone program can be set to microphone mode or telecoil mode. Your hearing instrument specialist will program your hearing system to your individual requirements. AutoPhone magnet accessory Some telephones produce a magnetic field strong enough to activate the AutoPhone function. Most types of telephones require a small magnet, available as an accessory, which can be attached to telephone receivers to activate the AutoPhone function. Ask your hearing instrument specialist about this accessory and if it is right for your hearing care needs. 18 Note: Magnets can pose risks to electronics and magnetic storage mediums when placed in close proximity. Take care not to set magnets near computers, color monitors, television sets, floppy discs, video/audio tape and other electronic equipment. Keep magnets away from the reach of children. If swallowed consult your physician. Magnets may interfere with the operation of life supporting systems (i.e. pace-makers, magnetic valves etc). Use magnet only if not in doubt about the safe distance. The Safe distance between pacemaker and magnet should be at least 10 cm (4 inch). Maintenance and care Your new CIELO hearing system is a highly sensitive system. Proper care and handling will ensure the best possible performance. Earwax may accumulate on your earmold. If not cleaned regularly you can damage the hearing system or cause health problems. Therefore: 1. It is essential to detach the ear- mold from your behind-the-ear system and then place it in the cleaning bath. Caution: Do NOT put the hearing system in water, only the earmold. 2. Occasionally bring your hearing system to your hearing instrument specialist to have the hearing tube changed and the system checked. Care tips: • You should place your hearing system in a "dry aid kit" with a special moisture-attracting capsule overnight. The drying capsule draws damaging moisture out of the system. • Your hearing instrument specialist can provide you with special care sets and drying capsules to keep your hearing system in good condition. Always store your hea- ring system in the case provided. 20 Important notes • Never expose your hearing system to extreme temperatures or high humidity. Do not store it in direct sunlight. Do not wear it when taking a shower or when applying hairspray. • As with all electrical, non gas-encapsulated systems, the hearing system must not be operated in explosion- endangered rooms. • Do not wear your hearing system during short-wave therapy, or if you work with medical treatments that use strong magnetic or high-frequency fields, such as a MRIs or X-rays. • Make sure to turn off the system when not in use. This helps preserve your batteries. • When not wearing your system for long periods of time, remove the batteries. This prevents leakage, which can some times occur in batteries. Replace batteries that have a leakage immediately. 21 Troubleshooting tips Your CIELO hearing system is an extremely reliable device. However, should a problem occur, this can usually be corrected quickly. Use this trouble shouting guide to sort out simple problems. PROBLEM CAUSE POSSIBLE SOLUTION System sound is weak Weak or dead battery System clogged Volume too low Replace with new battery Clean earmold Turn up volume control System whistles Improper seating in ear Volume control too high Clogged with wax or excessive wax in ears Crack in earmold tubing Try reinserting the instrument until it fits securely Lower volume control Clean earmold or contact ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории