Войти:
Оценок - 4, средний балл: 4.5 ( )

Инструкция по эксплуатации Datalogic Scanning, модель DS4800

Производитель: Datalogic Scanning
Размер: 2.5 mb
Название файла: ds4800quick_eng.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


2. Release the button to enter the Test mode function. Once entered, the Bar-Graph on the five LEDs is activated and if the scanner starts reading barcodes the Bar-Graph shows the Good Read Rate. In case of no read condition, only the STATUS LED is on and blinks. READY GOOD SETUP TRIGGER COM STATUS LEARN TEST green green yellow yellow red Figure 9 – X-PRESS™ Interface: Test Mode Function 3. To exit the Test Mode, press the X-PRESS™ push button once. By default, the Test Mode exits automatically after two minutes. NOTE DS4800 QUICK GUIDE ADVANCED SCANNER CONFIGURATION For further details on advanced product configuration, refer to the complete Reference Manual on the installation CD-ROM or downloadable from the web site through this link: The following are alternative or advanced scanner configuration methods: HOST MODE PROGRAMMING The scanner can also be configured from a host computer using the Host Mode programming procedure, by commands via the serial interface. See the Host Mode Programming file on the CD-ROM. ADVANCED GENIUS™ CONFIGURATION The ADVANCED selection available when starting the Genius™ program is addressed to expert users being able to complete a detailed scanner configuration. By choosing this option it is possible either to start a new scanner configuration or to open and modify an old one. The desired parameters can be defined in the following window, similar to the MS Explorer: Figure 10 - Genius™ Parameter Explorer Window ALTERNATIVE LAYOUTS • The ID-NET™ network is a built-in high-speed interface dedicated for high-speed scanner interconnection. ID-NET™ is in addition to the Main and Auxiliary serial interfaces. If you need to install an ID-NET™ network refer to the DS4800 Reference Manual. The scanner can also be configured by reading programming barcodes. See the ID-NET™ Setup Procedure Using Programming Barcodes printable from the CD-ROM. • If you need to install a Pass-Through network refer to the DS4800 Reference Manual. • If you need to install a Multiplexer network refer to the DS4800 Reference Manual. • If you need to install an RS232 Master/Slave (for backward compatibility) refer to the DS4800 Reference Manual. DS4800 QUICK GUIDE APPENDIX READING DIAGRAMS DS4800-1000 Focus Distance 30 cm (Near) 0 0 5 10 10 20 30 15 40 20 50 25 60 30 70 80 3590 (in) 40 100 (cm) CONDITIONS Code = Code 128 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° *Scan Speed = 800 scans/sec *Reading Conditions = Standard *Reading Mode = Linear * Parameter selectable in Genius™ (in) 10 5 0 5 20 15 10 15 20 50 40 30 20 10 0 10 20 30 40 50 (cm) 0.38 mm (15 mils) . 0.50 mm (20 mils) 0.30 mm (12 mils) 0.20 mm (8 mils) DS4800 QUICK GUIDE DS4800-1000 Focus Distance 40 cm (Medium) 0 5 10 15 20 25 30 35 40 (in) 0 10 20 30 40 50 60 70 80 90100 (cm) CONDITIONS Code = Code 128 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° *Scan Speed = 800 scans/sec *Reading Conditions = Standard *Reading Mode = Linear * Parameter selectable in Genius™ 10 5 0 5 20 15 10 15 20 (in) 50 40 30 20 10 0 10 20 30 40 50 (cm) 0.38 mm (15 mils) . 0.50 mm (20 mils) 0.30 mm (12 mils) DS4800-1000 Focus Distance 60 cm (Far) 0 5 10 15 20 25 30 35 40 (in) 45 0 10 20 30 40 50 60 70 80 90 100 110 120 (cm) CONDITIONS Code = Code 128 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° *Scan Speed = 800 scans/sec *Reading Conditions = Standard *Reading Mode = Linear * Parameter selectable in Genius™ (cm) 10 5 0 5 20 15 10 15 20 (in) 60 50 40 30 20 10 0 10 20 30 40 50 60 0.38 mm (15 mils) . 0.50 mm (20 mils) DS4800 QUICK GUIDE READING PERFORMANCE Version Reading Distance Max Code Resolution mm (mils) Speed scans/s F = 30 20 cm (7.9 in) - 47 cm (18.5 in) on 0.50 mm (20 mils) codes 0.20 (8) 800 F = 40 25 cm (9.8 in) - 68 cm (26.8 in) on 0.50 mm (20 mils) codes 0.30 (12) 800 F = 60 40 cm (16.7 in) - 100 cm (39.4 in) on 0.50 mm (20 mils) codes 0.38 (15) 800 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply 10 to 30 Vdc Max. Consumption 0.6 to 0.2 A; 6 W Main Serial Interfaces Baud Rate Programmable: RS232, RS485 FD and HD 1200 to 115200 Auxiliary Interface Baud Rate RS232 1200 to 115200 ID-NET™ Interface Baud Rate RS485 Half Duplex Up to 1Mbaud Inputs Input 1 (External Trigger), Input 2 Voltage Current Consumption Minimum Pulse Duration Optocoupled, polarity insensitive 10 to 30 Vdc 12 mA max. 5 ms Outputs Output 1, Output 2 VCE Collector Current VCE Saturation Power Dissipation Optocoupled 30 Vdc max. 40 mA continuous max.; 130 mA pulsed max. 1V at 10 mA max. 80 mW max. at 45 °C (ambient temperature) OPTICAL FEATURES Light Source Semiconductor laser diode Wavelength In the range 630 to 680 nm Safety Class Class 2 – EN 60825-1; CDRH READING FEATURES Scan Rate (software programmable) Aperture Angle Maximum Reading Distance Maximum Resolution 600 to 900 scans/sec 50° See reading diagrams ENVIRONMENTAL FEATURES Operating Temperature 0° to +50 °C (+32° to +122 °F) • Storage Temperature -...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории