Фрагмент инструкции


MSI/PLESSEY AIM ID = DISABLE MSI/PLESSEY AIM ID = ENABLE Product Reference Guide 6-253 MSI/Plessey Label ID This feature specifies an MSI/Plessey label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF. 4. Complete the programming sequence by scanning the SWITCH bar code. SET MSI/PLESSEY LABEL ID 6-254 Magellan® 8500 Scanner MSI/Plessey Length Control This feature specifies whether variable-length or fixed-length decoding will be set for MSI/Plessey. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code. NOTE If variable-length control was selected, you must now set the features MSI/Plessey Maximum Label Length and MSI/Plessey Minimum Label Length. If fixed-length control was selected, you must now set I 2 of 5 Fixed Length 1 and MSI/Plessey Fixed Length 2. MSI/PLESSEY LENGTH CONTROL = VARIABLE-LENGTH MSI/PLESSEY LENGTH CONTROL = FIXED-LENGTH Product Reference Guide 6-255 MSI/Plessey Maximum Label Length This feature specifies the maximum allowable length of an MSI/Plessey label. NOTE Length in this case includes check and data characters, but does not include start, stop or full ASCII shift characters. This feature applies when MSI/Plessey Length Control is set to variable-length decoding. Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY MAXIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired maximum label length. The selectable range for this option is 4 to 16. Pad all single digit numbers with a leading zero to yield a two-digit entry (04-16). 4. Complete the programming sequence by scanning the SWITCH bar code. SET MSI/PLESSEY MAXIMUM LABEL LENGTH 6-256 Magellan® 8500 Scanner MSI/Plessey Minimum Label Length This feature specifies the minimum allowable length of an MSI/Plessey label. NOTE Length in this case includes check and data characters, but does not include start, stop or full ASCII shift characters. This applies when MSI/ Plessey Length Control is set to variable-length decoding. Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY MINIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired minimum label length. The selectable range for this option is 4 to 16. Pad all single digit numbers with a leading zero to yield a two-digit entry (04-16). 4. Complete the programming sequence by scanning the SWITCH bar code. SET MSI/PLESSEY MINIMUM LABEL LENGTH Product Reference Guide 6-257 MSI/Plessey Fixed Length 1 This feature specifies MSI/Plessey first fixed length. This applies when MSI/Plessey Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 4 to 16. Pad all single digit numbers with a leading zero to yield a two-digit entry (04-16). 4. Complete the programming sequence by scanning the SWITCH bar code. SET MSI/PLESSEY FIXED LENGTH 1 6-258 Magellan® 8500 Scanner MSI/Plessey Fixed Length 2 This feature specifies MSI/Plessey second fixed length. Th...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории