Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = On. * On Off Product Reference Guide Output Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the imager emits on a good read. Default = Medium. High * Medium Off Low Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the imager emits on a good read. Default = Medium. Low (1400 Hz) Medium (2800 Hz) * High (3100 Hz) PowerScan® 7000 2D Good Read Indicators Beeper Duration – Good Read The beeper duration codes modify the length of the beep the imager emits on a good read. Default = Normal. * Normal Beep Short Beep LED – Good Read The LED indicator can be programmed On or Off in response to a good read. Default = On. * On Off Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have five beeps, there will be five beeps and five LED flashes in response to a good read. The beeps and LED flashes are in sync with one another. To change the number of beeps, scan the bar code below and then scan a digit (1-9) bar code and the Save bar code on the Programming Chart on page B-5 of this manual. Default = One. Number of Pulses Product Reference Guide Output Good Read Delay This sets the minimum amount of time before the imager can read another bar code. Default = No Delay. * No Delay Short Delay (500 ms) Medium Delay (1,000 ms) Long Delay (1,500 ms) User-Specified Good Read Delay If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the Programming Chart on page B-5, then scanning Save. User-Specified Good Read Delay Trigger Modes Manual/Serial Trigger You can activate the imager either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 10-5). When in manual trigger mode, the imager scans until a bar code is read, or until the trigger is released. PowerScan® 7000 2D Trigger Modes When in serial mode, the imager scans until a bar code has been read or until the deactivate command is sent. In serial mode, the imager can also be set to turn itself off after a specified time has elapsed (see Read Time- Out, which follows). * Manual/Serial Trigger Read Time-Out Use this selection to set a time-out (in milliseconds) of the imager’s trigger when using serial commands to trigger the imager, or if the imager is in manual trigger mode. Once the imager has timed out, you can activate the imager either by pressing the trigger or using a serial trigger command. After scanning the Read Time-Out bar code, set the time-out duration (from 0-300,000 milliseconds) by scanning digits from the Programming Chart on page B-5, then scanning Save. Default = 0 (infinite, or no time-out). Read Time-Out Manual Trigger, Low Power The imager powers down until the trigger is pulled. When the trigger is pulled, the imager powers up and operates until there is no triggering for the time set with the Low Power Time-Out bar code below. There is a delay of up to one second in operation when the imager is first triggered, but there is no delay when operating in low power time-out mode. Manual Trigger, Low Power Low Power Time-Out Timer Scan the Low Power Time-Out bar code to change the time-out duration (in seconds). Then scan the time-out duration (from 0-300 seconds) from the Programming Chart on page B-5, and Save. Default = 120 seconds. Product Reference Guide Output If the unit remains idle during the low power time-out interval, the unit goes into low power mode. Whenever the trigger is enabled, the low power time-out timer is reset. Low Power Time-Out This time-out does not begin until the imager time-out setting has expired. NOTE PowerScan® 7000 2D Scan Stand Mode Scan Stand Mode When a unit is in Scan Stand mode, it remains idle as long as it sees the Scan Stand symbol. (See Scan Stand Symbol that follows.) When a different code is presented, the Imager is triggered to read the new code. Note:The imager automatically adjusts the illumination LEDs to the lowest light level possible to maintain a good lock on the Scan Stand symbol. When a symbol is presented, the imager’s light levels adjust to the saved setting (see LED Power Level on page 3-10). Scan Stand Mode Scan Stand Symbol When a unit is in Scan Stand mode, the LEDs shine at the Scan Stand symbol on the base of the stand which tells it to remain idle. When the Scan Stand symbol is covered, the imager turns the LEDs on at the configured power level (Default High) and attempts to find and decode bar codes in its field of view. Scan Stand Symbol Presentation Mode This programs the imager to work in Presentation Mode. Presentation Mode Product Reference Guide Output Presentation LED...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории