Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации Echo, модель X750-006

Производитель: Echo
Размер: 514.34 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Some believe that prolonged exposure to vibration may contribute to CTS. CTS can cause severe pain for months or even years. To reduce the risk of RSI/CTS, do the following: • Avoid using your wrist in a bent, extended or twisted position. Instead try to maintain a straight wrist position. Also, when grasping, use your whole hand, not just the thumb and index finger. • Take periodic breaks to minimize repetition and rest your hands. • Reduce the speed & force in which you do the repetitive movement. • Do exercises to strengthen the hand and arm muscles. • Immediately stop using all power equipment and consult a doctor if you feel tingling, numbness or pain in the fingers, hands, wrists or arms. The sooner RSI/CTS is diagnosed, the more likely permanent nerve and muscle damage can be prevented. 8 DESCRIPTION EMISSION CONTROL EPA Phase II The emission control system for these engines are EM (Engine Modification). An Emission Control Label is located on the engine. (This is an EXAMPLE ONLY, information on label varies by engine FAMILY). PRODUCT EMISSION DURABILITY The 300 hours emission durability period is the time span selected by the manufacturer certifying the engine emissions output meets applicable California emissions regulations, provided that approved maintenance procedures are followed as listed in the Maintenance Section of this manual. CONTENTS 1 - Power Head 1 - Blower Pipe Assembly 1 - Operator’s Manual 1 - Warranty Registration Card 1 - ECHO Emissions and Warranty Statement 1 - Echo Power Blend TM 2-stroke oil sample POWER BLOWER OPERATOR’S MANUAL 1 2 3 4 5 6 7 8 9 1. AIR CLEANER -Contains replaceable air filter element. 2. SPARK PLUG -Provides spark to ignite fuel mixture. 3. MUFFLER/SPARK ARRESTOR -The spark arrestor muffler controls the exhaust noise while the spark arrestor prevents hot, glowing particles of carbon from leaving the muffler. 4. RECOIL STARTER HANDLE -Pull recoil handle slowly until starter engages, then return handle slowly. DO NOT let handle snap back or damage to unit will occur. 5. CHOKE LEVER -Push lever DOWN to close choke (starting position) and for emergency stopping. Lift UP to open choke (run position). 6. FUEL TANK CAP -For closing the fuel tank. 7. THROTTLE LEVER -Controls engine speed. 8. STOP SWITCH -“Toggle Switch” 9. SHOULDER HARNESS -Used to support unit on operator’s back. The straps are adjustable. 10. BLOWER PIPES - 11. FLEXIBLE PIPE -Allows for full range of movement. 10 11 P/N 89016006361 P/N 89016003360 10 SPECIFICATIONS MODEL PB-410 Length 330 mm (13.0 in.) (w/o pipes) Width 440 mm (17.3 in.) Height 440 mm (17.3 in.) Mass (dry) 9.7 kg (21.4 Ib.) (w/o pipes) Engine Type Air cooled, two-stroke, single cylinder gasoline engine Displacement 39.7 mL (2.42 cu. in.) Bore 38.0 mm (1.50 in.) Stroke 35.0 mm (1.38 in.) Carburetor Walbro Diaphragm, model WT-684 Ignition System Flywheel Magneto, capacitor discharge ignition type Spark Plug NGK BPM-8Y Gap 0.65 mm (0.026 in.) Exhaust System Spark Arrestor Muffler w / Catalyst Fuel Mixed (Gasoline and Two-stroke Oil) Fuel/Oil Ratio 50:1 ECHO High Performance, two-stroke air cooled engine oil Gasoline 89 Octane unleaded. DO NOT use fuel containing methyl alcohol. Gasoline may contain 15 % MTBE (methyl tertiary-butyl ether). Oil 50:1 ECHO High Performance, two-stroke air cooled engine oil Fuel Tank Capacity 1.5 L (50.7 US fl. oz.) Recoil Starter System Automatic Recoil Starter Centrifugal Type Wide Open Throttle Speed (r/min) 7000 - 7600 Idle Speed (r/min) 2200 - 3000 Maximum Air Volume 10.6 m3/min. (375 cu. ft./min.) Maximum Air Speed w/pipes (m/s) 78 (175 mph) Sound Level at 50 ft. dB(A) scale per ANSI B175.2 72 dB(A) POWER BLOWER OPERATOR’S MANUAL ASSEMBLY WARNING DANGER Never perform maintenance or assembly procedures with engine running or serious personal injury may result. Stick handle INSTALL BLOWER PIPES 1. Assemble throttle lever bracket to the fancase using four screws. -Set stop lead into the recess of bracket. 2. Assemble the flexible pipe thru elbow to the blower and tighten clamp. 3. Assemble the flexible pipe and the straight pipe w/swivel and tighten the clamp. Flexible pipe 4. Assemble straight section of the pipe to the other end of the pipe. 5. Assemble the curved pipe and rotate the desired angle. 6. Shoulder harness is adjustable to fit any operator. 7. Adjust the length of strap for easier operation. Clamp Elbow Pipe Screws Stop lead INSTALL STICK HANDLE 1. Remove blower pipe from swivel tube. Stick handle 2. Loosen wing nut completely and expand open stick handle. 3. Align notches in handle clamp with pipe pegs. Handle should be angled away from operator. 4. Slide handle onto swivel tube. 5. Position handle for comfortable operation and tighten wing nut. 6. Install blower pipe to swivel tube. Swivel tube Wing nut Notch Pipe pegs 12 PRE-OPERATION FUEL Fuel Requirements Gasoline -Use 89 Octane [R+M/2] (mid grade or higher) gasoline known to be good quality. Gasoline may contain up to 15% MTBE (methy...

Эта инструкция также подходит к моделям:
Системы вентиляции - PB-410 (514.34 kb)
Системы вентиляции - X750109-290 (514.34 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории