Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Lennox Hearth, модель COUNTRY COLLECTION 506033-35

Производитель: Lennox Hearth
Размер: 988.29 kb
Название файла: Lennox_Hearth_Installation_Wood_Stoves_Blower_Snap_Switch_506033-35.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Blower Wire Harness (item #1) 1 ea. Snap Switch and Control Panel Housings (item #2) 1 ea. 6” of 3/4” Heat Shrink Tube (item #3) 2 ea. Butt Connectors (item #4) 3 ea. Wire Ties (item #5) 1 ea. Instruction Sheet TOOLS NEEDED 5/32 Allen Wrench Or T Handle Wrench Cutting Pliers Wire Crimpers 9/16” Socket Wrench 9/16” Open End Wrench Crescent Wrench 3/8” End Wrench Large Flat Head Screwdriver 4 2 3 5 Figure 1 - Kit Contents GENERAL INFORMATION This retrofit kit works in conjunction with the optional 700-CFM room air circulation blower kit. The kit provides a variable speed control (rheostat) and snap switch, which will allow for the option of automatic thermal activation of the blower, when desired and blower speed control (see Blower Operation on Page 8). If you encounter any problems, need clarification of these instructions or are not qualified to properly install this kit, contact your local distributor or dealer. Read this instruction sheet in its entirety before beginning the installation. ALL WARNINGS AND pRECAUTIONS IN ThE INSTALLATION AND OpERATION MANUAL pROVIDED WITh ThE AppLIANCE AppLY TO ThESE INSTRUCTIONS. ShUTDOWNThESTOVEANDALLOWITTOCOMpLETELYCOOLBEFORE pROCEEDING. WARNINGS The blower must be plugged directly into a properly groundedthree prongreceptacle, 20VAC,60 hz,single phase. Do not cut or remove the grounding prong from this plug. Do not route power cord under or in front of appliance. Installation must be in accordance with National Elec trical Code, ANSI/NFpA 70 latest edition. In Canada, the current CSA C22- Canadian Electrical Code latest edition. DANGER: Disconnect power before servicing blower. In the event that you remove the blower for any reason, make sure a cover plate (available from Lennox hearth products) is installed before using the heater. Excessive rear wall temperatures will result if the stove is burned without the cover plate. The cover plate is not necessary if a blower has never been installed because a knock-out will be in place to act as the cover. FREESTANDING BLOWER SNAp SWITCh RETROFIT KIT Cat. No. Model Description h79 8 SSK-BLWR-FSB700 Blower Retrofit Kit, FS Woodstoves NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Step . UNpLUG pOWER CORD AND ENSURE AppLIANCE IS COLD Step 2. Usinga5/32allenwrench/T-handle,removetheblowermounting allen screws from blower, and remove blower from stove. See Figure 2. Figure 4 Cut black wires on motor side of butt connectors Butt Connectors Stove Back Blower Figure 2 Step 3. Using a crescent wrench, remove the fan blade. NOTE: Fan nut is reverse thread. Step 4. Using a 3/8” end wrench, remove the ground (green) wire from the blower stud. See Figure 3. Step 7. Strip blower wires and connect butt connectors to both. See Figures 6 and 7. Step 5. Carefully remove the black heat shrink sleeve material from blower wires. Step 6. Cut both butt connectors on the motor side. Note: Cut at the connector being careful to not remove any more wire than is necessary. See Figures 4 and 5. Cut Wires Shown Figure 5 Green Ground Wire Figure 3 Strip wires as shown Figure 6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 10 Crimp on butt connectors to both wires Figure 10 Crimp on butt connectors to both wires Step 0.Reconnect the new ground wire to the motor stud. See Figure Step 8. Slide the supplied 6” of 3/4” heat shrink tube over the (3) blower 11. harness wires. See Figure 8. heat shrink tube Figure 8 Step 9. butt connectors already installed. Green Ground Wire . Wire Loom Tubing Figure 9 heat Shrink Tube Figure 12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 2.Shrink the tube with heat (heat gun, hair dryer, etc.) Step 2.Shrink the tube with heat (heat gun, hair dryer, etc.) Wires / heat Shrink Tube Figure 13 Wire Ties Figure 14 Step 4. Reinstall the blower fan blade. Step 5. Reinstall the blower assembly as shown in Figure 2 and the following instructions; Ensure the wiring harness on the blower cage is at the bottom right when mounted to the back heat shield of the stove. Be aware that the blower wiring harness should be clear of the back of the firebox and blower fan blades. The blower can now be fastened to the back of the heat shield with the four screws and washers that were removed earlier in this step using the 5/32” allen wrench/T-handle. Visually inspect that the blower is centered in large opening on the back of the heatshield. If not centered in the opening the fan blades could make contact with the heatshield making excessive noise. Once everything is correctly in place you can then tighten down all four screws. Tighten the screws moderately tight but do not over tighten as you may strip the holes out. WOODSTOVES WITh pEDESTAL BASE Leg based units, see instructions on Page 6. Step . From rear of stove, using a 9/16” wrench or socket, loosen both left and right pedestal mounting bolts but do not fully remove the bolts from threaded holes as shown in Figure 15. Ba...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории