Войти:
Оценок - 1, средний балл: 5 ( )

Инструкция по эксплуатации Air King, модель B1125

Производитель: Air King
Размер: 143.01 kb
Название файла:
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


Install transformer into hood canopy by lining up the 2 holes on the flange of the transformer with the 2 screw studs in the top left side of the hood canopy. Use 2 of the included 8-32 screws to make the connection and fully tighten (Figure 1). Figure 3 Keyholes Stud w/Hex Nuts Screw Stud Figure 1 Transformer Rear Wall 2.Attach the capacitor to the blower by lining up the two holes on the flange of the capacitor with the holes on the blower. Use the 2 included #6 screws to make the connection and fully tighten (Figure 2). Receptacles Figure 4 Blower Transformer SECTION 3 Installation into 10" High Canopy 1.Remove the rear bottom plate of the hood canopy. It is secured in place with a screw and washer on either side (Figure 5). Figure 2 Capacitor 111597006 New 3-07 2 of 12 Figure 5 Screw Bottom Plate Washer Channel Figure 6 Screw Bottom Plate Washer Screw Bottom Plate Washer Channel Figure 6 Screw Bottom Plate Washer 2. Install transformer into hood canopy by lining up the 2 holes on the flange of the transformer with the 2 screw studs in the top left side of the hood canopy. Use 2 of the included 8-32 screws to make the connection and fully tighten (Figure 1). 3. Attach the capacitor to the blower by lining up the two holes on the flange of the capacitor with the holes on the blower. Use the 2 included #6 screws to make the connection and fully tighten (Figure 2). 4. Lift blower up into the hood canopy and slide the keyhole slots in the blower mounting flange over the two studs of the hood. Slide the blower into place and tighten the hex nuts on the mounting stud while lining up the 8 holes in the blower mounting flange to the 8 screw studs of the hood (Figure 3). 5. Using 8 of the included 8-32 screws and washers, mount the blower in place and tighten all screws. Confirm that the blower is securely seated in place and there are no air gaps around the blower gasket. 6. Plug the 3 wire quick connect cord from the blower into the receptacle on the range hood canopy. Plug the 4 wire quick connect cord from the blower into the receptacle on the transformer. Connect one end of the wiring harness to the connector coming out of the transformer and the other end to the receptacle in the range hood canopy. These cords will only fit into the receptacles one way (Figure 4). 7. Reinstall the rear bottom plate by fitting the back edge of the plate into the channel located on the back of the hood and reinstalling the two screws and washers removed in Step 1(Figure 6). SECTION 4 Finishing the Installation 1. Install the included fuse into the electrical panel by turning the fuse cap counter clockwise and pulling out. Insert the included 1/4" x 1-1/4" time delay fuse in the holder and reinstall into the panel (Figure 7). Fuse Figure 7 Cap NOTE: If you need to replace the fuse, replace with a 1/4" x 1-1/4" Bussman MDA-10 or equivalent 10 amp, 250V ceramic, time delay fuse only. 2.Refer to the hood instruction manual to complete the installation, for maintenance, and before restoring power. 3.The blower is covered under the range hood’s warranty. 111597006 New 3-07 3 of 12 REPLACEMENT PARTS DIAGRAM 5 1 2 3 6 4 8 7 9 # Qty. Description Replacement Part # 1 1 Blower Assembly 5S1136123 2 1 Blower Gasket 5S1136124 3 8 Grommet 5S1136101 4 8 Washers 5S1136102 5 10 8-32 Screws 5S1136103 6 1 Capacitor 5S1136128 7 2 # 6 Screw 5S1136129 8 1 Transformer 5S1136066 9 1 Fuse 5S1136131 111597006 New 3-07 4 of 12 Modeles B900, B1125 La Soufflante INSTRUCTIONS IMPORTANTES – MANUEL D’OPERATION Modeles B900, B1125 La Soufflante INSTRUCTIONS IMPORTANTES – MANUEL D’OPERATION LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPERER OU DE REPARER LE PRODUIT DECRIT. PROTEGEZ VOUS-MEME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SECURITE. FAILLIR A SE CONFORMER AUX INSTRUCTIONS PEUT RESULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE A LA PROPRIETE. CONSERVER CES INSTRUCTIONS POUR REFERENCES ...

Эта инструкция также подходит к моделям:
Системы вентиляции - B900 (143.01 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории