Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Air King, модель AK110PN

Производитель: Air King
Размер: 137.09 kb
Название файла: 1b373d20-706d-47cd-b688-9bca585fa8bd.pdf
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. NOTE: This unit includes a side access panel for wiring that does not require the removal of the fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove the blower assembly and internal wiring compartment. Both methods are equally effective. 1a. External Wire Compartment: Remove the wire compartment cover screw and place cover in a secure place (Figure 5). INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Exhaust Fan 1. Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have: 1 - Grill 1 - Damper Assembly (attached) 4 - Mounting Rails 1 - Instruction/Safety Sheet 2. Choose the location for your fan. To ensure the best air and sound performance, it is recommended that the length of ducting and the number of elbows be kept to a minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise and airflow restrictions. This fan will require at least 8" of clearance in the ceiling or wall, and will mount through drywall up to 3/4" thick. The fan mounts between 16" or 24" on center joists using the 4 provided mounting rails. 3. Select the most convenient electrical knockout and remove using a straightblade screw driver (Figure 1). SECTION 2 New Construction 1. Install the side rails on the housing and position the housing next to the joist. Line up housing so that it will be flush with the finished ceiling. Secure the ends of the rails with screws or nails (not included) to the joists and slide the housing into the final position (Figure 2). SECTION 3 Existing Construction 1. Set housing in position between the joist and trace an outline onto the ceiling material (Figure 3). Set housing aside and cut opening, being careful not to cut or damage any electrical or other hidden utilities. Install the side rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the rails to the joists (Figure 2). Figure 1 Figure 2 210952009 Rev. B 2-06 2 of 8 Joist Housing Hanger Bar Figure 3 Joist 1b. Internal Wire Compartment: Remove the screw holding the venturi 4. Carefully tuck wire back inside wire compartment and replace wire in place. Lift the venturi up and at an angle to slide it out of the compartment cover securing with the screw that was removed earlier. housing (Figure 6). Remove the wire compartment cover screw and place the cover in a secure place (Figure 7). SECTION 6 NOTE: If the fan motor plug is connected to the fan housing receptacle, unplug so the venturi can be completely removed. Figure 6 Plug Screw Venturi Completing the Installation 1. If the fan’s blower assembly was removed during the wiring process, reinstall the blower by r...

Эта инструкция также подходит к моделям:
Системы вентиляции - AK110 (137.09 kb)
Системы вентиляции - AK130 (137.09 kb)
Системы вентиляции - AK50LS (137.09 kb)
Системы вентиляции - AK80 (137.09 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории