Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Echo, модель PB-755S H

Производитель: Echo
Размер: 639.81 kb
Название файла: e450022c-7341-4a29-ad3d-b0e29f69b073.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


IMPORTANT ENGINE INFORMATION ENGINE FAMILY: 9EHXS.0635KB DISPLACEMENT: 63.3 CC EMISSION COMPLIANCE PERIOD : 300 HRS. THIS ENGINE MEETS U.S. EPA PH2 EXH AND 2007 AND LATER CALIFORNIA EXH AND EVAP EMISSION REGULATIONS FOR S.O.R.E. REFER TO OWNER'S MANUAL FOR MAINTENANCE SPECIFICATIONS AND ADJUSTMENTS. An Emission Control Label is located on the unit. (This is an EXAMPLE ONLY, information on label varies by engine FAMILY). PRODUCT EMISSION DURABILITY (EMISSION COMPLIANCE PERIOD) The 300 hour emission compliance period is the time span selected by the manufacturer certifying the engine emissions output meets applicable emissions regulations, provided that approved maintenance procedures are followed as listed in the Maintenance Section of this manual. POWER BLOWER OPERATOR'S MANUAL DESCRIPTION PB-755SH Locate these safety decals on your unit. Make sure the decals are legible and that you understand and follow the instructions on them. If a decal cannot be read, a new one can be ordered from your ECHO dealer. See PARTS ORDERING instructions for specific information. P/N X505002310 Hot Decal (near muffler)1 2 3 6 78 9 10 11 12 13 4 5 General Warning Decal (located on blower housing) P/N 89016009461 Sound Label (located on blower housing) 74 Category IIIdB(A) Measured at 50 ft. (15m) per ANSI B175.2 P/N X508000180 ). 1. SPARK PLUG -Provides spark to ignite fuel mixture. 2. SAFETY DECAL -Lists important safety precautions. 3. SPARK ARRESTOR - CATALYTIC MUFFLER / MUFFLER -The muffler or catalytic muffler controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler. Keep exhaust area clear of flammable debris. 4. CHOKE -Move lever up to "Cold Start" ( ) starting position and for emergency stopping. Move lever down to Run position ( 5. PURGE BULB - Pumping purge bulb before starting engine draws fresh fuel from the fuel tank, purging air from the carburetor. Pump purge bulb until fuel is visible and flows freely in the clear fuel tank return line. Pump purge bulb an additional 4 or 5 times. 6. RECOIL STARTER HANDLE - Pull recoil handle slowly until starter engages, then quickly and firmly. When engine starts, return handle slowly. DO NOT let handle snap back or damage to unit will occur. 7. FUEL TANK- Contains fuel and fuel filter. 8. FUEL TANK CAP -Covers and seals fuel tank. 9. AIR CLEANER -Contains replaceable air filter element. 10. HANDLE -Rotates downward for throttle control access. Spring loaded for flexible operation. 11. BLOWER PIPES -Exclusive positive locking system. 12. SHOULDER HARNESS -Used to support unit on operator's back. The straps are adjustable. 13. THROTTLE POSITION LEVER/STOP SWITCH -Combination stop switch and variable speed throttle lever. When the lever is moved all the way forward the blower is at Wide Open Throttle (W.O.T.). When the lever is moved rearward to detent, the blower is at idle. When the lever is moved rearward past the idle detent the blower will stop. POWER BLOWER OPERATOR'S MANUAL PB-755ST Locate these safety decals on your unit. Make sure the decals are legible and that you understand and follow the instructions on them. If a decal cannot be read, a new one can be ordered from your ECHO dealer. See PARTS ORDERING instructions for specific information. 11 Hot Decal (near muffler) 6 General Warning Decal (located on Sound Label (located on blower blower housing) housing) 3 5 4 78 9 P/N X505002310 12 2 10 1 13 14 15 74 Category III dB(A) Measured at 50 ft. (15m) per ANSI B175.2 P/N 89016009461 P/N X508000180 1. SPARK PLUG -Provides spark to ignite fuel mixture. 2. SAFETY DECAL -Lists important safety precautions. 3. SPARK ARRESTOR - CATALYTIC MUFFLER / MUFFLER -The muffler or catalytic muffler controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler. Keep exhaust area clear of flammable debris. 4. CHOKE -Move lever up to "Cold Start" ( ) starting position and for emergency stopping. Move lever down to Run position ( ). 5. PURGE BULB - Pumping purge bulb before starting engine draws fresh fuel from the fuel tank, purging air from the carburetor. Pump purge bulb until fuel is visible and flows freely in the clear fuel tank return line. Pump purge bulb an additional 4 or 5 times. 6. RECOIL STARTER HANDLE - Pull recoil handle slowly until starter engages, then quickly and firmly. When engine starts, return handle slowly. DO NOT let handle snap back or damage to unit will occur. 7. FUEL TANK- Contains fuel and fuel filter. 8. FUEL TANK CAP -Covers and seals fuel tank. 9. AIR CLEANER -Contains replaceable air filter element. 10. THROTTLE POSITION LEVER -Pull back to increase engine speed. Friction washers maintain throttle lever setting. 11. STOP SWITCH -Slide switch mounted on top of handle. Move forward to run, back to stop. 12. HANDLE -Used by operator to direct and control air flow. 13. SHOULDER HARNESS -Used to support unit on operator's ...

Эта инструкция также подходит к моделям:
Системы вентиляции - PB-755S T (639.81 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории