|
Фрагмент инструкции
3) Connect the DMX input of the first slave unit to the DMX output of the master unit 4) Connect the DMX input of the subsequent slave units to the DMX output of the previous slave unit. 5) Finish setting and connecting all the slave units. Master unit: 1) Set the master unit to operate in either, Automatic, Laser Sky, or Sound mode, as previously indicated. 2) Make the master unit the first unit in the DMX daisy chain. • Wait until all the slave units are configured and connected before connecting the master unit to the DMX daisy chain. • Never connect a DMX controller to a DMX string configured for Master/Slave operation because it may interfere with the signals from the master unit. Do not connect more than 31 slave units to the master unit. DMX Channel Assignments and Values Channel Function Value Setting 1 Control Mode (Use channels 2~10 in this mode) 000 . 017 018 . 035 036 . 053 054 . 071 072 . 089 090 . 107 108 . 125 126 . 143 144 . 161 162 . 179 180 . 197 198 . 215 216 . 233 234 . 255 Manual Mode Automatic fast color 1 Automatic slow color 1 Automatic fast color 2 Automatic slow color 2 Automatic fast color 3 Automatic slow color 3 Automatic fast mixed colors Automatic slow mixed colors Sound color 1 Sound color 2 Sound color 3 Sound mixed colors Random (Auto) 2 Pattern selection (Only when CH1 is between 000~017) 000 . 255 32 patterns, as shown in page 20 3 Color selection 000 . 024 025 . 049 050 . 074 075 . 099 100 . 124 125 . 149 150 . 174 175 . 199 200 . 224 225 . 255 Blackout Preprogrammed Color Color 1 Color 2 Color 3 Alternate Color 1/2 Alternate Color 2/3 Alternate Color 1/3 Alternate Color 1/2/3 Color Roll 4 Color Changing Speed 000 . 004 005 . 255 Stop Slow . fast 5 Zoom 000 . 127 128 . 169 170 . 209 210 . 255 100%~5% Zoom In Macro Zoom Out Macro Zoom In and Out Macro 6 X-Axis Move (Pan) 000 . 127 128 . 191 192 . 255 128 different positions on Y-Axis Move Left to right to Left (slow . fast) Move Left to right to Left (fast . slow) 7 Y-Axis Move (Tilt) 000 . 127 128 . 191 192 . 255 128 different positions on X-Axis Move Up to down to Up (slow . fast) Move Up to down to Up (fast . slow) 8 X-Axis Roll 000 . 127 128 . 191 192 . 255 Y-Axis Roll Roll (slow . fast) Roll (fast . slow) 9 Y-Axis Roll 000 . 127 128 . 191 192 . 255 Y-Axis Roll Roll (slow . fast) Roll (fast . slow) 10 Rotate 000 . 127 128 . 191 192 . 255 Z-Axis Roll Clockwise Rotate Counterclockwise Rotate 00-007 096-103 190-197 008-015 104-111 198-205 016-023 112-119 206-221 024-031 120-127 214-221 032-039 128-135 222-229 040-047 136-143 230-237 048-055 144-151 238-245 056-063 152-159 246-255 064-071 160-167 072-079 168-175 080-087 176-181 088-095 182-189 DMX Ch.2 Pattern Selection DMX VALUE PATTERN DMX VALUE PATTERN DMX VALUE PATTERN 000~007 096~103 190~197 008~015 104~111 198~205 016~023 112~119 206~213 024~031 120~127 214~221 032~039 128~135 222~229 040~047 136~143 230~237 048~055 144~151 238~245 056~063 152~159 246~255 064~071 160~167 072~079 168~175 080~087 176~181 088~095 182~189 Important Icon - B&W 02-600.gif CAUTION B&W Triangle - 200x171.gif 5. TECHNICAL INFORMATION Fixture Maintenance Dust build up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and mechanical wear. To maintain optimum performance and minimize wear, you should clean your lighting fixtures at least twice a month. However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency. To clean this lighting fixture, follow the instructions below: • Unplug the fixture from power. • Wait until the fixture is cold. • Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external surface and fan vents. • Clean the glass panel (laser aperture) with a mild solution of glass cleaner or isopropyl alcohol. • Apply the solution directly to a soft, lint-free cotton cloth or a lens cleaning tissue, and drag any dirt or grime to the outside of the glass. • Gently polish the glass surface until it is free of haze and lint. Always dry the glass surface carefully after cleaning them. • Refrain from spinning the fan using compressed air because you could damage it. • DO NOT open this fixture for cleaning or servicing. Important Icon - B&W 02-600.gif General Troubleshooting Symptom Possible Cause Possible Action Circuit breaker or fuse keeps blowing • Excessive load on the circuit • Make sure that the total load does not exceed 80% of the breaker or fuse nominal current • Short circuit along the power lines • Check the power lines and power cords Product does not power up • No energy on power outlet • Check power outlet • Change to another outlet • Loose or damaged power cord • Check the power cord • Blown fuse • Replace blown fuse with a good one of the same type and rating • Internal problem • Send product for repair Fixture does not respond to DMX • Wrong starting address on the fixture • Set the correct starting address on t...
Эта инструкция также подходит к моделям:Шредеры - SCORPION GVC (1.25 mb)
Шредеры - SCORPION RGY (1.25 mb)