Model No. Description TABLE MOUNT HARDWARE TM1276 Table Mount bracket for 2U . Rack- Wide RACK MOUNTING ACCESSORIES DA1298RM Rack mount shelf for two units side by side DA1299RM Rack ears for single unit. CONTROL CABLES RC5204CC Contact Closure Adapter 6 ft RC5207CC Master-Slave Control cable HIGH RESOLUTION VGA CABLE CB3703MR 3 feet VGA Male to Male CB3706MR 6 feet VGA Male to Male CB3715MR 15 feet VGA Male to Male CB3725MR 25 feet VGA Male to Male CB3750MR 50 feet VGA Male to Male CB3775MR 75
7. […F] – Feedback After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string. 8. […P] – Path This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. See examples in ON and OFF commands. 9. [SW] – Switch The switch command immediately connects inputs and o
Command Format: [ -] [-] = Decrement level by one-step Example: See the [SEL] command example. VOLUME RAMPING FEATURE: MT110-102 ONLY The following 7 commands are used to control the volume of the MT110-102. They may be used with computer control, but also are designed to be used with the {SETVK} command using keys on the Front Panel. The following code sample sets front panel keys 8 and 10 to Ramp Up and Ramp Down respectively. See your Front Panel User’s Guide for more details. When defined as
If a signal is not being received, make sure that the display is compatible with the resolution of the computer graphics card. CONGRATULATIONS! YOU ARE DONE. If you experience any problems, please call 1-800-258-4623 or 1-714-990-2300 for international calls. OPERATION 7 ACCESSORIES 8 Model No. Description RACK MOUNTING ACCESSORIES DA1295RM Mount mini-brackets (2 – “L” shape) CONTACT CLOSURE SWITCH RC5203CC Contact Closure with 6 ft. cable HIGH RESOLUTION 4 BNC to 4 BNC COAXIAL CABLE CB4100MR Bu
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. • Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to ope
We are sure you will find it a reliable and useful product. Superior performance for the right price backed by solid technical and customer support is what we have to offer. The product you are holding in your hands is designed using state-of-the-art technology and is superior to anything available on the market. You will find this and our other products reliable, long lasting, and simple to operate. We are committed to providing our customers with solutions to the most demanding audio-visual in
After processing a valid command, an [OK] string will be returned. The [VERN] command will return the corresponding software version being used by the switcher, such as an error string, [ERR] will be returned. If the control system being used is not setup to wait for the [OK] string, it is important to include a 100 millisecond delay between each command. 7 SWITCHERS The MX2216RM Switcher is also designed to send feedback commands from the switcher to the control system when the buttons on the f
OPERATION 7 7.1 OPERATION FROM THE FRONT PANEL The front panel of the MX2226AT provides access to essentially all of the switcher’s capabilities. It has three sections: input select, switcher functions, and output control. 7.1.2 INPUT SELECT SECTION SELECTION OF INPUT: When the buttons INPUT1 through INPUT6 are pressed, the corresponding INPUT will be selected. The LED on top of the bottom front panel will TURN ON simultaneously to indicate which input has been selected. When connected as a 1-in
Operation of this equipment in a residential area is likely to 2 SWITCHERS cause harmful interference in which case the user will be required to correct the interference at his own expense. • Any changes or modifications to the unit not expressly approved by Altinex, Inc. could void the user’s authority to operate the equipment. ABOUT YOUR SWITCHER 2 The DA1916SX is a 2-in, 1-out VGA (VGA/SVGA/XGA) Auto Switcher with manual remote capability through the use of a contact closure. The DA1916SX aut
Using this command, the user may also operate the switcher manually. n = ON/OFF switch n = 1 (turns auto switcher ON) n = 0 (turns auto switcher OFF) Example: Sending the [OAS1] command will set the auto switch feature to the ON position to detect the incoming video signal automatically. 9. [0I#] - Change Identification Number This command sets a unique ID number to each MX2456RM Switcher being used. A maximum of 9 unit ID’s can be assigned. 0 = Zero # = New switcher module ID number. (no. from