Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации HP, модель HP HyperFabric

Производитель: HP
Размер: 45.07 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


HyperFabric Release Notes
Known Problems and Workarounds
Known Problems and Workarounds
The known problems and their workarounds in this version of HyperFabric are as follows:

HyperFabric initialization may fail if the STRMSGSZ kernel parameter is set.
Workaround: Set STRMSGSZ to 0 on /stand/system from the command line to unset the
parameter.

The switch management software in HyperFabric may exhibit the following symptoms:
— The HyperFabric management daemon (clic_mgmtd) loses connection with other
nodes in the cluster.
— Invalid class messages, class messages that are not related to HyperFabric are logged
into the /var/adm/clic_log global log file.
Workaround: Disconnect the HyperFabric switch or switches from the Ethernet
network, and leave them disconnected. Then, reconfigure HyperFabric by using the
clic_init -c command or SAM, but do not configure switch management.
HyperFabric works correctly without the switch management configured; but the switches
do not create diagnostic logs.

When you run the clic_probe nodename -c adapter_ID command, if the adapter
specified by adapter_ID is not operational—and another (operational) adapter is
installed in the “source” node (the node you specified the clic_probe command
from)—clic_probe uses the other adapter.
However, clic_probe does not notify you that the adapter you specified is not operational.
This will be fixed in a future release.

Some of the directory structures of the Hyperfabric software remains on the system even
after removing the Hyperfabric software (for example, /opt/clic). This will be fixed in a
future release.
Chapter 1
7


...

Эта инструкция также подходит к моделям:
Сетевое оборудование - HP-UX 11i v2 I/O Cards (45.07 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории